An uncertainties simulation model applied to an automated laminar flowmeter

Detalhes bibliográficos
Autor(a) principal: Pedro, António
Data de Publicação: 2020
Outros Autores: Morgado, Teresa, Navas, Helena
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://hdl.handle.net/10362/105312
Resumo: Aircraft oxygen regulators are a normally used specialized test bench designed to perform tests to the regulators during its work conditions. The tests are performed placing the regulator in the barometric chamber, where low pressure conditions are forced to simulate altitude conditions and then a flow is forced on the output of the regulator to simulate the inhalation of the user. The relevant test flows are measured by laminar flowmeters. These flowmeters are meant to measure the flowrate at pressures correspondent to altitudes between sea level altitude and fifty thousand feet. In this work a way was studied to automate laminar flowmeters used on oxygen regulator test benches. For this purpose, was developed a data acquisition system (DAS) using a microcontroller board and two microelectromechanical systems-MEMSs (a pressure and temperature sensor and a differential pressure sensor). Since these MEMSs did not have factory calibration, they were calibrated in this study. The automated flowmeter was also calibrated. To estimate the error of flow rate measured by this solution, an uncertainties simulation model based on the Monte Carlo method and several calibrations were performed. According to the automated flowmeter calibration, the uncertainty obtained (0.45% fs) is accepted, but the authors only recommend its use for actual volumetric flowrate measurements.
id RCAP_c65c2bd4b65f021bfae6dbd021f3abaa
oai_identifier_str oai:run.unl.pt:10362/105312
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling An uncertainties simulation model applied to an automated laminar flowmeterAir data test setAircraft oxygen systemAutomated laminar flowmeterCalibrationMonte Carlo methodTest benchUncertaintyMaterials Science(all)InstrumentationEngineering(all)Process Chemistry and TechnologyComputer Science ApplicationsFluid Flow and Transfer ProcessesAircraft oxygen regulators are a normally used specialized test bench designed to perform tests to the regulators during its work conditions. The tests are performed placing the regulator in the barometric chamber, where low pressure conditions are forced to simulate altitude conditions and then a flow is forced on the output of the regulator to simulate the inhalation of the user. The relevant test flows are measured by laminar flowmeters. These flowmeters are meant to measure the flowrate at pressures correspondent to altitudes between sea level altitude and fifty thousand feet. In this work a way was studied to automate laminar flowmeters used on oxygen regulator test benches. For this purpose, was developed a data acquisition system (DAS) using a microcontroller board and two microelectromechanical systems-MEMSs (a pressure and temperature sensor and a differential pressure sensor). Since these MEMSs did not have factory calibration, they were calibrated in this study. The automated flowmeter was also calibrated. To estimate the error of flow rate measured by this solution, an uncertainties simulation model based on the Monte Carlo method and several calibrations were performed. According to the automated flowmeter calibration, the uncertainty obtained (0.45% fs) is accepted, but the authors only recommend its use for actual volumetric flowrate measurements.DEMI - Departamento de Engenharia Mecânica e IndustrialUNIDEMI - Unidade de Investigação e Desenvolvimento em Engenharia Mecânica e IndustrialRUNPedro, AntónioMorgado, TeresaNavas, Helena2020-10-08T22:53:29Z2020-02-012020-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10362/105312eng2076-3417PURE: 17462380https://doi.org/10.3390/app10030888info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-22T17:47:59Zoai:run.unl.pt:10362/105312Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T17:19:02.684528Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv An uncertainties simulation model applied to an automated laminar flowmeter
title An uncertainties simulation model applied to an automated laminar flowmeter
spellingShingle An uncertainties simulation model applied to an automated laminar flowmeter
Pedro, António
Air data test set
Aircraft oxygen system
Automated laminar flowmeter
Calibration
Monte Carlo method
Test bench
Uncertainty
Materials Science(all)
Instrumentation
Engineering(all)
Process Chemistry and Technology
Computer Science Applications
Fluid Flow and Transfer Processes
title_short An uncertainties simulation model applied to an automated laminar flowmeter
title_full An uncertainties simulation model applied to an automated laminar flowmeter
title_fullStr An uncertainties simulation model applied to an automated laminar flowmeter
title_full_unstemmed An uncertainties simulation model applied to an automated laminar flowmeter
title_sort An uncertainties simulation model applied to an automated laminar flowmeter
author Pedro, António
author_facet Pedro, António
Morgado, Teresa
Navas, Helena
author_role author
author2 Morgado, Teresa
Navas, Helena
author2_role author
author
dc.contributor.none.fl_str_mv DEMI - Departamento de Engenharia Mecânica e Industrial
UNIDEMI - Unidade de Investigação e Desenvolvimento em Engenharia Mecânica e Industrial
RUN
dc.contributor.author.fl_str_mv Pedro, António
Morgado, Teresa
Navas, Helena
dc.subject.por.fl_str_mv Air data test set
Aircraft oxygen system
Automated laminar flowmeter
Calibration
Monte Carlo method
Test bench
Uncertainty
Materials Science(all)
Instrumentation
Engineering(all)
Process Chemistry and Technology
Computer Science Applications
Fluid Flow and Transfer Processes
topic Air data test set
Aircraft oxygen system
Automated laminar flowmeter
Calibration
Monte Carlo method
Test bench
Uncertainty
Materials Science(all)
Instrumentation
Engineering(all)
Process Chemistry and Technology
Computer Science Applications
Fluid Flow and Transfer Processes
description Aircraft oxygen regulators are a normally used specialized test bench designed to perform tests to the regulators during its work conditions. The tests are performed placing the regulator in the barometric chamber, where low pressure conditions are forced to simulate altitude conditions and then a flow is forced on the output of the regulator to simulate the inhalation of the user. The relevant test flows are measured by laminar flowmeters. These flowmeters are meant to measure the flowrate at pressures correspondent to altitudes between sea level altitude and fifty thousand feet. In this work a way was studied to automate laminar flowmeters used on oxygen regulator test benches. For this purpose, was developed a data acquisition system (DAS) using a microcontroller board and two microelectromechanical systems-MEMSs (a pressure and temperature sensor and a differential pressure sensor). Since these MEMSs did not have factory calibration, they were calibrated in this study. The automated flowmeter was also calibrated. To estimate the error of flow rate measured by this solution, an uncertainties simulation model based on the Monte Carlo method and several calibrations were performed. According to the automated flowmeter calibration, the uncertainty obtained (0.45% fs) is accepted, but the authors only recommend its use for actual volumetric flowrate measurements.
publishDate 2020
dc.date.none.fl_str_mv 2020-10-08T22:53:29Z
2020-02-01
2020-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/105312
url http://hdl.handle.net/10362/105312
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2076-3417
PURE: 17462380
https://doi.org/10.3390/app10030888
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833596609079803904