Export Ready — 

Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization

Bibliographic Details
Main Author: Campos, R.
Publication Date: 2018
Other Authors: Machado Jr., G., Cerqueira, M. F., Borme, J., Alpuim, P.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/1822/48567
Summary: Since the discovery of graphene, and due to its unique properties, we have witnessed a growing interest in the use of graphene-based devices for applications in the most diverse areas, namely in biosensing, particularly in the detection of genetic material. DNA can bind directly to graphene without the need of a linker and that makes this platform highly interesting for biosensor development. Here, electrochemical chips consisting of 6 independent gold microelectrode arrays as working electrode, and platinum reference and counter electrodes were fabricated at the wafer scale and, after graphene transfer and patterning, were used in the detection of DNA hybridization. Combining the sensitivity of electrochemical impedance spectroscopy and the selectivity of DNA beacons, we were able to detect DNA hybridization in a linear range between 5 pM and 5 nM, which is in the relevant clinical range for many diseases, with sensitivity to single nucleotide polymorphism.
id RCAP_c1571b0a924be0804f13c7fbca9ae650
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/48567
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridizationGraphenegenosensorelectrochemical chipsingle nucleotide polymorphismCiências Naturais::Ciências FísicasCiências Naturais::Ciências BiológicasEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e InformáticaEngenharia e Tecnologia::Engenharia dos MateriaisEngenharia e Tecnologia::NanotecnologiaScience & TechnologySince the discovery of graphene, and due to its unique properties, we have witnessed a growing interest in the use of graphene-based devices for applications in the most diverse areas, namely in biosensing, particularly in the detection of genetic material. DNA can bind directly to graphene without the need of a linker and that makes this platform highly interesting for biosensor development. Here, electrochemical chips consisting of 6 independent gold microelectrode arrays as working electrode, and platinum reference and counter electrodes were fabricated at the wafer scale and, after graphene transfer and patterning, were used in the detection of DNA hybridization. Combining the sensitivity of electrochemical impedance spectroscopy and the selectivity of DNA beacons, we were able to detect DNA hybridization in a linear range between 5 pM and 5 nM, which is in the relevant clinical range for many diseases, with sensitivity to single nucleotide polymorphism.Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UID/FIS/04650/2013info:eu-repo/semantics/acceptedVersionElsevierUniversidade do MinhoCampos, R.Machado Jr., G.Cerqueira, M. F.Borme, J.Alpuim, P.20182018-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://hdl.handle.net/1822/48567eng0167-931710.1016/j.mee.2017.12.015info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T05:10:55Zoai:repositorium.sdum.uminho.pt:1822/48567Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:11:01.816738Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
title Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
spellingShingle Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
Campos, R.
Graphene
genosensor
electrochemical chip
single nucleotide polymorphism
Ciências Naturais::Ciências Físicas
Ciências Naturais::Ciências Biológicas
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
Engenharia e Tecnologia::Engenharia dos Materiais
Engenharia e Tecnologia::Nanotecnologia
Science & Technology
title_short Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
title_full Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
title_fullStr Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
title_full_unstemmed Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
title_sort Wafer scale fabrication of graphene microelectrode arrays for the detection of DNA hybridization
author Campos, R.
author_facet Campos, R.
Machado Jr., G.
Cerqueira, M. F.
Borme, J.
Alpuim, P.
author_role author
author2 Machado Jr., G.
Cerqueira, M. F.
Borme, J.
Alpuim, P.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Campos, R.
Machado Jr., G.
Cerqueira, M. F.
Borme, J.
Alpuim, P.
dc.subject.por.fl_str_mv Graphene
genosensor
electrochemical chip
single nucleotide polymorphism
Ciências Naturais::Ciências Físicas
Ciências Naturais::Ciências Biológicas
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
Engenharia e Tecnologia::Engenharia dos Materiais
Engenharia e Tecnologia::Nanotecnologia
Science & Technology
topic Graphene
genosensor
electrochemical chip
single nucleotide polymorphism
Ciências Naturais::Ciências Físicas
Ciências Naturais::Ciências Biológicas
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
Engenharia e Tecnologia::Engenharia dos Materiais
Engenharia e Tecnologia::Nanotecnologia
Science & Technology
description Since the discovery of graphene, and due to its unique properties, we have witnessed a growing interest in the use of graphene-based devices for applications in the most diverse areas, namely in biosensing, particularly in the detection of genetic material. DNA can bind directly to graphene without the need of a linker and that makes this platform highly interesting for biosensor development. Here, electrochemical chips consisting of 6 independent gold microelectrode arrays as working electrode, and platinum reference and counter electrodes were fabricated at the wafer scale and, after graphene transfer and patterning, were used in the detection of DNA hybridization. Combining the sensitivity of electrochemical impedance spectroscopy and the selectivity of DNA beacons, we were able to detect DNA hybridization in a linear range between 5 pM and 5 nM, which is in the relevant clinical range for many diseases, with sensitivity to single nucleotide polymorphism.
publishDate 2018
dc.date.none.fl_str_mv 2018
2018-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/48567
url https://hdl.handle.net/1822/48567
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0167-9317
10.1016/j.mee.2017.12.015
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595789810597888