Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease

Bibliographic Details
Main Author: Corrà, MF
Publication Date: 2021
Other Authors: Atrsaei, A, Sardoreira, A, Hansen, C, Aminian, K, Correia, M, Vila-Chã, N, Maetzler, W, Maia, LF
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10216/152524
Summary: Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.
id RCAP_be5eb30b4a6435e3fe011958c4e12dea
oai_identifier_str oai:repositorio-aberto.up.pt:10216/152524
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s diseaseGait speedHuman gaitLab vs. homeMedication statesParkinson’s diseaseRemote patient monitoringWearable sensorsAccurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.MDPI20212021-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10216/152524eng1424-822010.3390/s21123974Corrà, MFAtrsaei, ASardoreira, AHansen, CAminian, KCorreia, MVila-Chã, NMaetzler, WMaia, LFinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:23:36Zoai:repositorio-aberto.up.pt:10216/152524Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:17:03.583562Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
title Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
spellingShingle Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
Corrà, MF
Gait speed
Human gait
Lab vs. home
Medication states
Parkinson’s disease
Remote patient monitoring
Wearable sensors
title_short Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
title_full Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
title_fullStr Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
title_full_unstemmed Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
title_sort Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
author Corrà, MF
author_facet Corrà, MF
Atrsaei, A
Sardoreira, A
Hansen, C
Aminian, K
Correia, M
Vila-Chã, N
Maetzler, W
Maia, LF
author_role author
author2 Atrsaei, A
Sardoreira, A
Hansen, C
Aminian, K
Correia, M
Vila-Chã, N
Maetzler, W
Maia, LF
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Corrà, MF
Atrsaei, A
Sardoreira, A
Hansen, C
Aminian, K
Correia, M
Vila-Chã, N
Maetzler, W
Maia, LF
dc.subject.por.fl_str_mv Gait speed
Human gait
Lab vs. home
Medication states
Parkinson’s disease
Remote patient monitoring
Wearable sensors
topic Gait speed
Human gait
Lab vs. home
Medication states
Parkinson’s disease
Remote patient monitoring
Wearable sensors
description Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.
publishDate 2021
dc.date.none.fl_str_mv 2021
2021-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/152524
url https://hdl.handle.net/10216/152524
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1424-8220
10.3390/s21123974
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600088653430784