Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio

Bibliographic Details
Main Author: Ferreira, Mariana Afonso Correia de Queirós
Publication Date: 2018
Format: Master thesis
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10316/84913
Summary: Dissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia
id RCAP_ba9d7e29e5d1d06e1f02c2a9f7048d3b
oai_identifier_str oai:estudogeral.uc.pt:10316/84913
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frioParameters that have an impact on the fire behavior of columns with sigma cross-section of cold-formed steelColunaAço enformado a frioSigmaFogoRestrição axialColumnCold-formed steelSigmaFireAxial restrainingDissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e TecnologiaA elevada procura de elementos em aço enformado a frio na indústria da construção levou à criação de normas de dimensionamento à temperatura ambiente. No entanto, ainda não foram estabelecidas normas de dimensionamento específicas para este tipo de elementos em caso de incêndio, situação em que as estruturas de aço são suscetíveis de sofrer fenómenos de instabilidade e degradação das suas propriedades mecânicas.Este trabalho teve como objetivo avaliar o comportamento de colunas simples e compostas de aço enformado a frio, respetivamente colunas de secção transversal Sigma e 2 Sigma, em situação de incêndio. Os perfis em sigma apresentam maior capacidade resistente em relação à encurvadura quando comparadas com perfis semelhantes (em C) devido à presença de reforços na alma. Para esta avaliação foi utilizado o software Abaqus, recorrendo ao método de elementos finitos. Os modelos numéricos utilizados foram calibrados com base em ensaios experimentais já realizados no laboratório de estruturas do Departamento de Engenharia Civil da Universidade de Coimbra.Este trabalho foi dividido em duas partes, a primeira consistiu na calibração do modelo numérico que foi criado a partir dos resultados dos ensaios experimentais, e a segunda teve como objetivo analisar a influência de alguns parâmetros não avaliados experimentalmente, como as dimensões da secção transversal (espessura, largura e altura), comprimento das colunas, diferentes níveis de carregamento, restrição e condições de apoio.Apesar do comportamento das colunas compostas de aço enformado a frio em situação de incêndio ser relativamente desconhecido, estas apresentam vantagens estruturais e económicas. Todavia, em situação de incêndio, as metodologias de dimensionamento presentes na EN 1993-1-2 (2005) necessitam de verificação, pois adotam coeficientes de redução das propriedades mecânicas do aço laminado para secções de Classe 4 e limitam os elementos a uma temperatura crítica de 350 ºC, o que não se verificou ser adequado nem nos resultados dos ensaios experimentais realizados nem para alguns dos casos estudados nesta dissertação.The high demand for cold-formed steel elements in the construction industry led to the creation of design guidelines when at room temperature. However, it hasn’t been yet established any design guidelines for this kind of structural elements related to its behaviour under fire conditions, in which case these steel structures are at risk of instability phenomenon and degradation of their mechanical properties.This study aimed at evaluate the behaviour of simple and built-up columns of cold-formed steel in a fire situation, columns of sigma and 2 sigma cross-section respectively. The sigma profiles represent a greater resistance to buckling when compared to similar profiles (in C) due to the presence of reinforcements in its web. This evaluation was made with the Abaqus software, using the finite elements method. The numeric models used were calibrated based on prior experimental trials already performed at the Civil Engineering Department Laboratory of the University of Coimbra.The methodology in this study was undertaken in two parts, the first one consisted on the calibration of the numeric model that was created with the experimental trial, and the second one consisted on the analysis of the influence of other non-experimentally tested parameters, such as crossed section design (thickness, width and height), length of columns, different levels of loading, restriction and support conditions.Despite the behavior of build-up columns of cold-formed steel under fire conditions is still relatively unknown, these elements still reveal both structural and economic advantages. Therefore, under fire conditions, the design guidelines presented in the EN 1993-1-2 (2005) might require verification, as they adopt mechanical properties’ reduction coefficients of rolled steel for Class 4 sections, and limit the elements to a critical temperature of 350 ºC, which has not been adequate for every situation as it was observed on the experimental trials’ results and in some of this dissertation results.2018-09-21info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttps://hdl.handle.net/10316/84913https://hdl.handle.net/10316/84913TID:202172414porFerreira, Mariana Afonso Correia de Queirósinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2020-05-29T13:46:35Zoai:estudogeral.uc.pt:10316/84913Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:31:58.254448Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
Parameters that have an impact on the fire behavior of columns with sigma cross-section of cold-formed steel
title Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
spellingShingle Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
Ferreira, Mariana Afonso Correia de Queirós
Coluna
Aço enformado a frio
Sigma
Fogo
Restrição axial
Column
Cold-formed steel
Sigma
Fire
Axial restraining
title_short Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
title_full Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
title_fullStr Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
title_full_unstemmed Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
title_sort Parâmetros que afetam o comportamento ao fogo de colunas com perfis em sigma de aço enformados a frio
author Ferreira, Mariana Afonso Correia de Queirós
author_facet Ferreira, Mariana Afonso Correia de Queirós
author_role author
dc.contributor.author.fl_str_mv Ferreira, Mariana Afonso Correia de Queirós
dc.subject.por.fl_str_mv Coluna
Aço enformado a frio
Sigma
Fogo
Restrição axial
Column
Cold-formed steel
Sigma
Fire
Axial restraining
topic Coluna
Aço enformado a frio
Sigma
Fogo
Restrição axial
Column
Cold-formed steel
Sigma
Fire
Axial restraining
description Dissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia
publishDate 2018
dc.date.none.fl_str_mv 2018-09-21
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/84913
https://hdl.handle.net/10316/84913
TID:202172414
url https://hdl.handle.net/10316/84913
identifier_str_mv TID:202172414
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602385820254208