Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients

Bibliographic Details
Main Author: Adsuar, J
Publication Date: 2021
Other Authors: Parraca, J, Raimundo, A, Garcia-Gordillo, M, Polero, P, Romas-Carus, P
Format: Article
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10174/31951
https://doi.org/Adsuar J, Parraca J, Raimundo A, Garcia-Gordillo M, Polero P, Tomas-Carus P. (2021) Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients. Sustainability, 13(3), 1343; https://doi.org/10.3390/su13031343
https://doi.org/10.3390/su13031343
Summary: Background: Reliability studies are used to verify the evaluation accuracy of a given device. Strength is an important factor for the development of daily activities and its correct management is fundamental. The objective of this study was to examine the reliability of a concentric strength test in people with type 2 diabetes mellitus (T2DM). Methods: Twenty-seven individuals with T2DM performed three repetitions of extension-flexion in concentric-concentric action at 60°/s, for both legs, using an isokinetic dynamometer. For the reliability analysis, we performed an intra-session test retest. Results: The total sample and men sub-group intra-class correlation coefficient (ICC) values were excellent for peak torque and work. In the women sub-group, ICC values were excellent for extensors in both peak torque and work; however, concerning flexor, the ICC values were good for peak torque while, for work, they were good for the right leg and moderate for the left leg. Standard error of measurement (SEM) percentage oscillated from 3.85% to 6.80%, with the smallest real difference (SRD) percentage being from 10.66% to 18.86% for peak torque. Furthermore, the SEM (%) was around 5.5% and SRD (%) was around 15% for work. Conclusions: The isokinetic dynamometry had “good” to “excellent” relative reliability for peak torque (0.862–0.983) and work (0.744–0.982) of extension-flexion in concentric-concentric action at 60°/s. In addition, our study showed that, in general, an SRD < 20% could indicate a true change in strength regarding this protocol in T2DM.
id RCAP_b8be56bcb4cb4b96638652711a27a9a9
oai_identifier_str oai:dspace.uevora.pt:10174/31951
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus PatientsreliabilityIsokinetic Knee StrengthType 2 DiabetesBackground: Reliability studies are used to verify the evaluation accuracy of a given device. Strength is an important factor for the development of daily activities and its correct management is fundamental. The objective of this study was to examine the reliability of a concentric strength test in people with type 2 diabetes mellitus (T2DM). Methods: Twenty-seven individuals with T2DM performed three repetitions of extension-flexion in concentric-concentric action at 60°/s, for both legs, using an isokinetic dynamometer. For the reliability analysis, we performed an intra-session test retest. Results: The total sample and men sub-group intra-class correlation coefficient (ICC) values were excellent for peak torque and work. In the women sub-group, ICC values were excellent for extensors in both peak torque and work; however, concerning flexor, the ICC values were good for peak torque while, for work, they were good for the right leg and moderate for the left leg. Standard error of measurement (SEM) percentage oscillated from 3.85% to 6.80%, with the smallest real difference (SRD) percentage being from 10.66% to 18.86% for peak torque. Furthermore, the SEM (%) was around 5.5% and SRD (%) was around 15% for work. Conclusions: The isokinetic dynamometry had “good” to “excellent” relative reliability for peak torque (0.862–0.983) and work (0.744–0.982) of extension-flexion in concentric-concentric action at 60°/s. In addition, our study showed that, in general, an SRD < 20% could indicate a true change in strength regarding this protocol in T2DM.2022-04-29T15:13:52Z2022-04-292021-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/31951https://doi.org/Adsuar J, Parraca J, Raimundo A, Garcia-Gordillo M, Polero P, Tomas-Carus P. (2021) Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients. Sustainability, 13(3), 1343; https://doi.org/10.3390/su13031343http://hdl.handle.net/10174/31951https://doi.org/10.3390/su13031343por1343https://www.mdpi.com/2071-1050/13/3/1343Sustainability13ndjparraca@uevora.ptammr@uevora.ptndndptc@uevora.pt251Adsuar, JParraca, JRaimundo, AGarcia-Gordillo, MPolero, PRomas-Carus, Pinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-01-03T19:32:08Zoai:dspace.uevora.pt:10174/31951Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:27:00.865311Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
title Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
spellingShingle Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
Adsuar, J
reliability
Isokinetic Knee Strength
Type 2 Diabetes
title_short Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
title_full Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
title_fullStr Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
title_full_unstemmed Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
title_sort Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients
author Adsuar, J
author_facet Adsuar, J
Parraca, J
Raimundo, A
Garcia-Gordillo, M
Polero, P
Romas-Carus, P
author_role author
author2 Parraca, J
Raimundo, A
Garcia-Gordillo, M
Polero, P
Romas-Carus, P
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Adsuar, J
Parraca, J
Raimundo, A
Garcia-Gordillo, M
Polero, P
Romas-Carus, P
dc.subject.por.fl_str_mv reliability
Isokinetic Knee Strength
Type 2 Diabetes
topic reliability
Isokinetic Knee Strength
Type 2 Diabetes
description Background: Reliability studies are used to verify the evaluation accuracy of a given device. Strength is an important factor for the development of daily activities and its correct management is fundamental. The objective of this study was to examine the reliability of a concentric strength test in people with type 2 diabetes mellitus (T2DM). Methods: Twenty-seven individuals with T2DM performed three repetitions of extension-flexion in concentric-concentric action at 60°/s, for both legs, using an isokinetic dynamometer. For the reliability analysis, we performed an intra-session test retest. Results: The total sample and men sub-group intra-class correlation coefficient (ICC) values were excellent for peak torque and work. In the women sub-group, ICC values were excellent for extensors in both peak torque and work; however, concerning flexor, the ICC values were good for peak torque while, for work, they were good for the right leg and moderate for the left leg. Standard error of measurement (SEM) percentage oscillated from 3.85% to 6.80%, with the smallest real difference (SRD) percentage being from 10.66% to 18.86% for peak torque. Furthermore, the SEM (%) was around 5.5% and SRD (%) was around 15% for work. Conclusions: The isokinetic dynamometry had “good” to “excellent” relative reliability for peak torque (0.862–0.983) and work (0.744–0.982) of extension-flexion in concentric-concentric action at 60°/s. In addition, our study showed that, in general, an SRD < 20% could indicate a true change in strength regarding this protocol in T2DM.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01T00:00:00Z
2022-04-29T15:13:52Z
2022-04-29
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10174/31951
https://doi.org/Adsuar J, Parraca J, Raimundo A, Garcia-Gordillo M, Polero P, Tomas-Carus P. (2021) Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients. Sustainability, 13(3), 1343; https://doi.org/10.3390/su13031343
http://hdl.handle.net/10174/31951
https://doi.org/10.3390/su13031343
url http://hdl.handle.net/10174/31951
https://doi.org/Adsuar J, Parraca J, Raimundo A, Garcia-Gordillo M, Polero P, Tomas-Carus P. (2021) Test-Retest Reliability of Isokinetic Knee Strength Measurements in Type 2 Diabetes Mellitus Patients. Sustainability, 13(3), 1343; https://doi.org/10.3390/su13031343
https://doi.org/10.3390/su13031343
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 1343
https://www.mdpi.com/2071-1050/13/3/1343
Sustainability
13
nd
jparraca@uevora.pt
ammr@uevora.pt
nd
nd
ptc@uevora.pt
251
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833592826720419840