Summary: In this work, a newly developed self-contained, portable, and compact iron measurement system (IMS) based on spectroscopy absorption for determination of Fe2+ in water is presented. One of the main goals of the IMS is to operate the device in the field as opposed to instruments commonly used exclusively in the laboratory. In addition, the system has been tuned to quantify iron concentrations in accordance with the values proposed by the regulations for human consumption. The instrument uses the phenanthroline standard method for iron determination in water samples. This device is equipped with an optical sensing system consisting of a light-emitting diode paired with a photodiode to measure absorption radiation through ferroin complex medium. To assess the sensor response, four series of Fe2+ standard samples were prepared with different iron concentrations in various water matrices. Furthermore, a new solid reagent prepared in-house was investigated, which is intended as a "ready-to-use" sample pre-treatment that optimizes work in the field. The IMS showed better analytical performance compared with the state-of-the-art instrument. The sensitivity of the instrument was found to be 2.5 mu g Fe2+/L for the measurement range established by the regulations. The linear response of the photodiode was determined for concentrations between 25 and 1000 mu g Fe2+/L, making this device suitable for assessing iron in water bodies.
id RCAP_b2db1280d78d9e88f4e7784c409cbc17
oai_identifier_str oai:bibliotecadigital.ipb.pt:10198/11935
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling A portable measurement device based on phenanthroline complex for iron determination in waterIronOptical sensorPortable deviceWaterAbsorbanceOpto-electronicChemistryEnvironmentHuman healthIn this work, a newly developed self-contained, portable, and compact iron measurement system (IMS) based on spectroscopy absorption for determination of Fe2+ in water is presented. One of the main goals of the IMS is to operate the device in the field as opposed to instruments commonly used exclusively in the laboratory. In addition, the system has been tuned to quantify iron concentrations in accordance with the values proposed by the regulations for human consumption. The instrument uses the phenanthroline standard method for iron determination in water samples. This device is equipped with an optical sensing system consisting of a light-emitting diode paired with a photodiode to measure absorption radiation through ferroin complex medium. To assess the sensor response, four series of Fe2+ standard samples were prepared with different iron concentrations in various water matrices. Furthermore, a new solid reagent prepared in-house was investigated, which is intended as a "ready-to-use" sample pre-treatment that optimizes work in the field. The IMS showed better analytical performance compared with the state-of-the-art instrument. The sensitivity of the instrument was found to be 2.5 mu g Fe2+/L for the measurement range established by the regulations. The linear response of the photodiode was determined for concentrations between 25 and 1000 mu g Fe2+/L, making this device suitable for assessing iron in water bodies.MDPIBiblioteca Digital do IPBFernandes, SamuelTlemcani, MouhaydineBortoli, DanieleFeliciano, ManuelLopes, Maria Elmina2015-07-06T13:03:46Z20232023-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/11935engFernandes, Samuel; Tlemcani, Mouhaydine; Bortoli, Daniele; Feliciano, Manuel; Lopes, Maria Elmina (2023). A portable measurement device based on phenanthroline complex for iron determination in water. Sensors. eISSN 1424-8220. 23:3, p. 1-1910.3390/s230310581424-8220info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-25T12:02:45Zoai:bibliotecadigital.ipb.pt:10198/11935Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T11:28:17.867111Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv A portable measurement device based on phenanthroline complex for iron determination in water
title A portable measurement device based on phenanthroline complex for iron determination in water
spellingShingle A portable measurement device based on phenanthroline complex for iron determination in water
Fernandes, Samuel
Iron
Optical sensor
Portable device
Water
Absorbance
Opto-electronic
Chemistry
Environment
Human health
title_short A portable measurement device based on phenanthroline complex for iron determination in water
title_full A portable measurement device based on phenanthroline complex for iron determination in water
title_fullStr A portable measurement device based on phenanthroline complex for iron determination in water
title_full_unstemmed A portable measurement device based on phenanthroline complex for iron determination in water
title_sort A portable measurement device based on phenanthroline complex for iron determination in water
author Fernandes, Samuel
author_facet Fernandes, Samuel
Tlemcani, Mouhaydine
Bortoli, Daniele
Feliciano, Manuel
Lopes, Maria Elmina
author_role author
author2 Tlemcani, Mouhaydine
Bortoli, Daniele
Feliciano, Manuel
Lopes, Maria Elmina
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Biblioteca Digital do IPB
dc.contributor.author.fl_str_mv Fernandes, Samuel
Tlemcani, Mouhaydine
Bortoli, Daniele
Feliciano, Manuel
Lopes, Maria Elmina
dc.subject.por.fl_str_mv Iron
Optical sensor
Portable device
Water
Absorbance
Opto-electronic
Chemistry
Environment
Human health
topic Iron
Optical sensor
Portable device
Water
Absorbance
Opto-electronic
Chemistry
Environment
Human health
description In this work, a newly developed self-contained, portable, and compact iron measurement system (IMS) based on spectroscopy absorption for determination of Fe2+ in water is presented. One of the main goals of the IMS is to operate the device in the field as opposed to instruments commonly used exclusively in the laboratory. In addition, the system has been tuned to quantify iron concentrations in accordance with the values proposed by the regulations for human consumption. The instrument uses the phenanthroline standard method for iron determination in water samples. This device is equipped with an optical sensing system consisting of a light-emitting diode paired with a photodiode to measure absorption radiation through ferroin complex medium. To assess the sensor response, four series of Fe2+ standard samples were prepared with different iron concentrations in various water matrices. Furthermore, a new solid reagent prepared in-house was investigated, which is intended as a "ready-to-use" sample pre-treatment that optimizes work in the field. The IMS showed better analytical performance compared with the state-of-the-art instrument. The sensitivity of the instrument was found to be 2.5 mu g Fe2+/L for the measurement range established by the regulations. The linear response of the photodiode was determined for concentrations between 25 and 1000 mu g Fe2+/L, making this device suitable for assessing iron in water bodies.
publishDate 2015
dc.date.none.fl_str_mv 2015-07-06T13:03:46Z
2023
2023-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10198/11935
url http://hdl.handle.net/10198/11935
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Fernandes, Samuel; Tlemcani, Mouhaydine; Bortoli, Daniele; Feliciano, Manuel; Lopes, Maria Elmina (2023). A portable measurement device based on phenanthroline complex for iron determination in water. Sensors. eISSN 1424-8220. 23:3, p. 1-19
10.3390/s23031058
1424-8220
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833591936040042496