Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.22/13967 |
Summary: | The main goal of the present study is to analyze and characterize the behavior of the middle ear, when a total ossicular replacement prosthesis (TORP) is used in the ossicular chain, in order to troubleshoot conductive hearing loss. Using a finite element model (FEM), a dynamic study of the middle ear was made. The displacement values were obtained at the umbo and stapes footplate, for a sound pressure level of 80 dB sound pressure level (SPL) applied at the tympanic membrane, when a cartilage in membrane-prosthesis interface of different diameters and thicknesses was used. The results were compared with the healthy middle ear model. The usage of this model aims to achieve a set of techniques that promotes the best possible performance of prosthesis in the middle ear. The present study allows to conclude that the rehabilitation of the middle ear with TORP can lead to the best results when used with 4 mm diameter cartilages, with a thin thickness of 0.3 mm. |
id |
RCAP_aab3209fdee44c4b39fe57bcf9a5f6e0 |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/13967 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysisBiomechanicsFinite element methodTORPMiddle earThe main goal of the present study is to analyze and characterize the behavior of the middle ear, when a total ossicular replacement prosthesis (TORP) is used in the ossicular chain, in order to troubleshoot conductive hearing loss. Using a finite element model (FEM), a dynamic study of the middle ear was made. The displacement values were obtained at the umbo and stapes footplate, for a sound pressure level of 80 dB sound pressure level (SPL) applied at the tympanic membrane, when a cartilage in membrane-prosthesis interface of different diameters and thicknesses was used. The results were compared with the healthy middle ear model. The usage of this model aims to achieve a set of techniques that promotes the best possible performance of prosthesis in the middle ear. The present study allows to conclude that the rehabilitation of the middle ear with TORP can lead to the best results when used with 4 mm diameter cartilages, with a thin thickness of 0.3 mm.World Scientific PublishingREPOSITÓRIO P.PORTOGentil, FernandaMarques, MarcoParente, MarcoMartins, PedroSanto, CarlaJorge, Renato Natal2019-06-12T16:08:48Z20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/13967eng0219-519410.1142/S0219519415400060info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-07T10:22:27Zoai:recipp.ipp.pt:10400.22/13967Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:51:02.379719Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
title |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
spellingShingle |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis Gentil, Fernanda Biomechanics Finite element method TORP Middle ear |
title_short |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
title_full |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
title_fullStr |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
title_full_unstemmed |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
title_sort |
Total ossicular replacement prosthesis of the middle ear: a biomechanical analysis |
author |
Gentil, Fernanda |
author_facet |
Gentil, Fernanda Marques, Marco Parente, Marco Martins, Pedro Santo, Carla Jorge, Renato Natal |
author_role |
author |
author2 |
Marques, Marco Parente, Marco Martins, Pedro Santo, Carla Jorge, Renato Natal |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
REPOSITÓRIO P.PORTO |
dc.contributor.author.fl_str_mv |
Gentil, Fernanda Marques, Marco Parente, Marco Martins, Pedro Santo, Carla Jorge, Renato Natal |
dc.subject.por.fl_str_mv |
Biomechanics Finite element method TORP Middle ear |
topic |
Biomechanics Finite element method TORP Middle ear |
description |
The main goal of the present study is to analyze and characterize the behavior of the middle ear, when a total ossicular replacement prosthesis (TORP) is used in the ossicular chain, in order to troubleshoot conductive hearing loss. Using a finite element model (FEM), a dynamic study of the middle ear was made. The displacement values were obtained at the umbo and stapes footplate, for a sound pressure level of 80 dB sound pressure level (SPL) applied at the tympanic membrane, when a cartilage in membrane-prosthesis interface of different diameters and thicknesses was used. The results were compared with the healthy middle ear model. The usage of this model aims to achieve a set of techniques that promotes the best possible performance of prosthesis in the middle ear. The present study allows to conclude that the rehabilitation of the middle ear with TORP can lead to the best results when used with 4 mm diameter cartilages, with a thin thickness of 0.3 mm. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 2015-01-01T00:00:00Z 2019-06-12T16:08:48Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/13967 |
url |
http://hdl.handle.net/10400.22/13967 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0219-5194 10.1142/S0219519415400060 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
World Scientific Publishing |
publisher.none.fl_str_mv |
World Scientific Publishing |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833600723795836928 |