Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.

Bibliographic Details
Main Author: Frazão, Sara
Publication Date: 2018
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://doi.org/10.48560/rspo.13270
Summary: Purpose: To evaluate fixation stability and retinal sensitivity in the central 10º in Intermediate Age-Related Macular Degeneration (AMD), correlating these values with focal retinal changes on retinography and fundus autofluorescence (FAF).   Methods: A cross-sectional observational study enrolling patients with intermediate AMD, analyzed concerning microperimetric macular sensitivity (MP3 Microperimeter, Nidek®, Inc.), color retinography and FAF (Topcon® DRI OCT). Other variables considered were best corrected visual acuity (BCVA), fixation stability and FAF pattern.   Results: This study evaluated 33 eyes of 18 patients with mean age of 75,55±6,14, and a mean BCVA of 71±9,1 letters (modified EDTRS grid). Mean retinal sensitivity was 21,9±5,04dB, and mean bivariate contour ellipse area (BCEA) 99,6% was 13,61±9,51º2, with 30,3% of eyes showing relatively unstable fixation. Concerning the individual analysis of macular points (N=561), we identified a greater decrease in retinal sensitivity in points of decreased FAF (17±8,3dB) and increased FAF (13,06±6dB) comparing with normal FAF (9,6±4,6dB) (p<0.001).   Conclusions: Changes in FAF seem to be closely related to decreased focal retinal sensitivity. BCVA may be insufficient as a retinal function evaluation tool in intermediate AMD, with most patients showing altered fixation stability and multiple focal changes in retinal sensitivity in the central 10º. Microperimetry could become a valuable tool in functional follow-up of these patients, in correlation with FAF as a structural evaluation exam.
id RCAP_aa22e244bf543f1c61d5966b0e4834a1
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/13270
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.Artigos OriginaisPurpose: To evaluate fixation stability and retinal sensitivity in the central 10º in Intermediate Age-Related Macular Degeneration (AMD), correlating these values with focal retinal changes on retinography and fundus autofluorescence (FAF).   Methods: A cross-sectional observational study enrolling patients with intermediate AMD, analyzed concerning microperimetric macular sensitivity (MP3 Microperimeter, Nidek®, Inc.), color retinography and FAF (Topcon® DRI OCT). Other variables considered were best corrected visual acuity (BCVA), fixation stability and FAF pattern.   Results: This study evaluated 33 eyes of 18 patients with mean age of 75,55±6,14, and a mean BCVA of 71±9,1 letters (modified EDTRS grid). Mean retinal sensitivity was 21,9±5,04dB, and mean bivariate contour ellipse area (BCEA) 99,6% was 13,61±9,51º2, with 30,3% of eyes showing relatively unstable fixation. Concerning the individual analysis of macular points (N=561), we identified a greater decrease in retinal sensitivity in points of decreased FAF (17±8,3dB) and increased FAF (13,06±6dB) comparing with normal FAF (9,6±4,6dB) (p<0.001).   Conclusions: Changes in FAF seem to be closely related to decreased focal retinal sensitivity. BCVA may be insufficient as a retinal function evaluation tool in intermediate AMD, with most patients showing altered fixation stability and multiple focal changes in retinal sensitivity in the central 10º. Microperimetry could become a valuable tool in functional follow-up of these patients, in correlation with FAF as a structural evaluation exam.Ajnet2018-05-20T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.48560/rspo.13270eng1646-69501646-6950Frazão, Sarainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2022-09-22T17:06:04Zoai:ojs.revistas.rcaap.pt:article/13270Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T10:22:11.890865Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
title Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
spellingShingle Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
Frazão, Sara
Artigos Originais
title_short Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
title_full Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
title_fullStr Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
title_full_unstemmed Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
title_sort Retinal Sensitivity and Fundus Autofluorescence in Intermediate Age related Macular Degeneration.
author Frazão, Sara
author_facet Frazão, Sara
author_role author
dc.contributor.author.fl_str_mv Frazão, Sara
dc.subject.por.fl_str_mv Artigos Originais
topic Artigos Originais
description Purpose: To evaluate fixation stability and retinal sensitivity in the central 10º in Intermediate Age-Related Macular Degeneration (AMD), correlating these values with focal retinal changes on retinography and fundus autofluorescence (FAF).   Methods: A cross-sectional observational study enrolling patients with intermediate AMD, analyzed concerning microperimetric macular sensitivity (MP3 Microperimeter, Nidek®, Inc.), color retinography and FAF (Topcon® DRI OCT). Other variables considered were best corrected visual acuity (BCVA), fixation stability and FAF pattern.   Results: This study evaluated 33 eyes of 18 patients with mean age of 75,55±6,14, and a mean BCVA of 71±9,1 letters (modified EDTRS grid). Mean retinal sensitivity was 21,9±5,04dB, and mean bivariate contour ellipse area (BCEA) 99,6% was 13,61±9,51º2, with 30,3% of eyes showing relatively unstable fixation. Concerning the individual analysis of macular points (N=561), we identified a greater decrease in retinal sensitivity in points of decreased FAF (17±8,3dB) and increased FAF (13,06±6dB) comparing with normal FAF (9,6±4,6dB) (p<0.001).   Conclusions: Changes in FAF seem to be closely related to decreased focal retinal sensitivity. BCVA may be insufficient as a retinal function evaluation tool in intermediate AMD, with most patients showing altered fixation stability and multiple focal changes in retinal sensitivity in the central 10º. Microperimetry could become a valuable tool in functional follow-up of these patients, in correlation with FAF as a structural evaluation exam.
publishDate 2018
dc.date.none.fl_str_mv 2018-05-20T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.48560/rspo.13270
url https://doi.org/10.48560/rspo.13270
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1646-6950
1646-6950
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Ajnet
publisher.none.fl_str_mv Ajnet
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833590765721223168