Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings

Bibliographic Details
Main Author: Soares dos Reis, Alexandre
Publication Date: 2022
Other Authors: Vaquero, Petra, Ferreira Dias, Marta, Tavares, Alice
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10773/36231
Summary: Besides energy poverty, a certain tolerance to discomfort justifies Portugal's low heating energy consumption. Once Portuguese buildings stock, previous to 1990, has a weak energy performance, it is crucial to reflect on how to make renovations with more assertive benefits (besides energy), such as those related to the health and comfort of occupants. Hence, we have studied a single house in the TRNSYS dynamic simulation tool. We performed a sensitivity analysis by simulating the same building in three locations based on Portuguese climatic winter zones: I1 – Santarém, I2 – Santa Maria da Feira, and I3 – Guarda, for two ranges of wall insulation thickness, in free float. Considering Fanger's Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) as the Passive Discomfort Index IDP, results suggest that lowering 20 mm on the insulation thickness does not substantially impact occupants' discomfort in winter. As the variations between scenarios considering PPD > 15%, PMV < -1, or IDP (Tair < 18 ºC) are very similar, IDP could be an alternative to PMV/PPD for assessing thermal discomfort in dwellings.
id RCAP_a70dc5dcbb38fbae9246ed28f6b81a83
oai_identifier_str oai:ria.ua.pt:10773/36231
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellingsDwellingsIDPPMV/PPDThermal discomfortTRNSYSBesides energy poverty, a certain tolerance to discomfort justifies Portugal's low heating energy consumption. Once Portuguese buildings stock, previous to 1990, has a weak energy performance, it is crucial to reflect on how to make renovations with more assertive benefits (besides energy), such as those related to the health and comfort of occupants. Hence, we have studied a single house in the TRNSYS dynamic simulation tool. We performed a sensitivity analysis by simulating the same building in three locations based on Portuguese climatic winter zones: I1 – Santarém, I2 – Santa Maria da Feira, and I3 – Guarda, for two ranges of wall insulation thickness, in free float. Considering Fanger's Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) as the Passive Discomfort Index IDP, results suggest that lowering 20 mm on the insulation thickness does not substantially impact occupants' discomfort in winter. As the variations between scenarios considering PPD > 15%, PMV < -1, or IDP (Tair < 18 ºC) are very similar, IDP could be an alternative to PMV/PPD for assessing thermal discomfort in dwellings.Elsevier2023-02-06T11:12:31Z2022-07-21T00:00:00Z2022-07-21info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10773/36231eng10.1016/j.egyr.2022.07.128Soares dos Reis, AlexandreVaquero, PetraFerreira Dias, MartaTavares, Aliceinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-06T04:43:02Zoai:ria.ua.pt:10773/36231Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T14:17:54.989413Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
title Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
spellingShingle Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
Soares dos Reis, Alexandre
Dwellings
IDP
PMV/PPD
Thermal discomfort
TRNSYS
title_short Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
title_full Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
title_fullStr Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
title_full_unstemmed Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
title_sort Passive discomfort index as an alternative to predicted mean vote and predicted percentage of dissatisfied to assess occupant’s thermal discomfort in dwellings
author Soares dos Reis, Alexandre
author_facet Soares dos Reis, Alexandre
Vaquero, Petra
Ferreira Dias, Marta
Tavares, Alice
author_role author
author2 Vaquero, Petra
Ferreira Dias, Marta
Tavares, Alice
author2_role author
author
author
dc.contributor.author.fl_str_mv Soares dos Reis, Alexandre
Vaquero, Petra
Ferreira Dias, Marta
Tavares, Alice
dc.subject.por.fl_str_mv Dwellings
IDP
PMV/PPD
Thermal discomfort
TRNSYS
topic Dwellings
IDP
PMV/PPD
Thermal discomfort
TRNSYS
description Besides energy poverty, a certain tolerance to discomfort justifies Portugal's low heating energy consumption. Once Portuguese buildings stock, previous to 1990, has a weak energy performance, it is crucial to reflect on how to make renovations with more assertive benefits (besides energy), such as those related to the health and comfort of occupants. Hence, we have studied a single house in the TRNSYS dynamic simulation tool. We performed a sensitivity analysis by simulating the same building in three locations based on Portuguese climatic winter zones: I1 – Santarém, I2 – Santa Maria da Feira, and I3 – Guarda, for two ranges of wall insulation thickness, in free float. Considering Fanger's Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) as the Passive Discomfort Index IDP, results suggest that lowering 20 mm on the insulation thickness does not substantially impact occupants' discomfort in winter. As the variations between scenarios considering PPD > 15%, PMV < -1, or IDP (Tair < 18 ºC) are very similar, IDP could be an alternative to PMV/PPD for assessing thermal discomfort in dwellings.
publishDate 2022
dc.date.none.fl_str_mv 2022-07-21T00:00:00Z
2022-07-21
2023-02-06T11:12:31Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10773/36231
url http://hdl.handle.net/10773/36231
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.egyr.2022.07.128
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833594476326551552