Assessment of the injection of grouts to repair cracks in rammed earth

Bibliographic Details
Main Author: Silva, Rui André Martins
Publication Date: 2016
Other Authors: Domínguez Martinez, O, Oliveira, Daniel V., Pereira, E. N. B., Soares, Edgar
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/1822/43835
Summary: Rammed earth constructions are known for their high seismic vulnerability, which menaces their preservation and puts in risk the life of millions of people living in regions with important seismic hazard. The poor conservation condition of many of these constructions largely contributes for the aforementioned situation. The presence of cracks is one common type of damage occurring in the walls, which debilitates their structural behaviour both for in-plane and out-of-plane loading. The injection of grouts has been studied recently as a solution to repair this type of damage. However, the repair effectiveness of this technique needs further research. This paper presents an experimental program, where the effectiveness of the injection of a mud and a commercial grout base on hydraulic lime for repairing cracks in rammed earth is compared. Diagonal compression test were carried out on wallets before and after repair, where the response was monitored with Digital Image Correlation (DIC). Furthermore, sonic tests were used as a technique to assess the repair efficiency by non-destructive means. In general, both types of grouts presented similar performance.
id RCAP_a24972211d49f314776235981e424c20
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/43835
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Assessment of the injection of grouts to repair cracks in rammed earthEarth constructionRammed earthRepairInjectionEngenharia e Tecnologia::Engenharia CivilRammed earth constructions are known for their high seismic vulnerability, which menaces their preservation and puts in risk the life of millions of people living in regions with important seismic hazard. The poor conservation condition of many of these constructions largely contributes for the aforementioned situation. The presence of cracks is one common type of damage occurring in the walls, which debilitates their structural behaviour both for in-plane and out-of-plane loading. The injection of grouts has been studied recently as a solution to repair this type of damage. However, the repair effectiveness of this technique needs further research. This paper presents an experimental program, where the effectiveness of the injection of a mud and a commercial grout base on hydraulic lime for repairing cracks in rammed earth is compared. Diagonal compression test were carried out on wallets before and after repair, where the response was monitored with Digital Image Correlation (DIC). Furthermore, sonic tests were used as a technique to assess the repair efficiency by non-destructive means. In general, both types of grouts presented similar performance.POCI-01-0145-FEDER-007633RILEMUniversidade do MinhoSilva, Rui André MartinsDomínguez Martinez, OOliveira, Daniel V.Pereira, E. N. B.Soares, Edgar2016-08-222016-08-22T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/43835enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T07:07:21Zoai:repositorium.sdum.uminho.pt:1822/43835Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:16:24.056683Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Assessment of the injection of grouts to repair cracks in rammed earth
title Assessment of the injection of grouts to repair cracks in rammed earth
spellingShingle Assessment of the injection of grouts to repair cracks in rammed earth
Silva, Rui André Martins
Earth construction
Rammed earth
Repair
Injection
Engenharia e Tecnologia::Engenharia Civil
title_short Assessment of the injection of grouts to repair cracks in rammed earth
title_full Assessment of the injection of grouts to repair cracks in rammed earth
title_fullStr Assessment of the injection of grouts to repair cracks in rammed earth
title_full_unstemmed Assessment of the injection of grouts to repair cracks in rammed earth
title_sort Assessment of the injection of grouts to repair cracks in rammed earth
author Silva, Rui André Martins
author_facet Silva, Rui André Martins
Domínguez Martinez, O
Oliveira, Daniel V.
Pereira, E. N. B.
Soares, Edgar
author_role author
author2 Domínguez Martinez, O
Oliveira, Daniel V.
Pereira, E. N. B.
Soares, Edgar
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Silva, Rui André Martins
Domínguez Martinez, O
Oliveira, Daniel V.
Pereira, E. N. B.
Soares, Edgar
dc.subject.por.fl_str_mv Earth construction
Rammed earth
Repair
Injection
Engenharia e Tecnologia::Engenharia Civil
topic Earth construction
Rammed earth
Repair
Injection
Engenharia e Tecnologia::Engenharia Civil
description Rammed earth constructions are known for their high seismic vulnerability, which menaces their preservation and puts in risk the life of millions of people living in regions with important seismic hazard. The poor conservation condition of many of these constructions largely contributes for the aforementioned situation. The presence of cracks is one common type of damage occurring in the walls, which debilitates their structural behaviour both for in-plane and out-of-plane loading. The injection of grouts has been studied recently as a solution to repair this type of damage. However, the repair effectiveness of this technique needs further research. This paper presents an experimental program, where the effectiveness of the injection of a mud and a commercial grout base on hydraulic lime for repairing cracks in rammed earth is compared. Diagonal compression test were carried out on wallets before and after repair, where the response was monitored with Digital Image Correlation (DIC). Furthermore, sonic tests were used as a technique to assess the repair efficiency by non-destructive means. In general, both types of grouts presented similar performance.
publishDate 2016
dc.date.none.fl_str_mv 2016-08-22
2016-08-22T00:00:00Z
dc.type.driver.fl_str_mv conference paper
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/43835
url http://hdl.handle.net/1822/43835
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv RILEM
publisher.none.fl_str_mv RILEM
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595843856302080