The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial

Bibliographic Details
Main Author: João,Mafalda
Publication Date: 2024
Other Authors: Areia,Miguel, Alves,Susana, Elvas,Luís, Brito,Daniel, Saraiva,Sandra, Cadime,Ana Teresa
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040
Summary: Abstract Introduction: Current guidelines suggest adding oral simethicone to bowel preparation for colonoscopy. However, its effect on key quality indicators for screening colonoscopy remains unclear. The primary aim was to assess the rate of adequate bowel preparation in split-dose high-volume polyethylene glycol (PEG), with or without simethicone. Methods: This is an endoscopist-blinded, randomized controlled trial, including patients scheduled for colonoscopy after a positive faecal immunochemical test. Patients were randomly assigned to 4 L of PEG split dose (PEG) or 4 L of PEG split dose plus 500 mg oral simethicone (PEG + simethicone). The Boston Bowel Preparation Scale (BBPS) score, the preparation quality regarding bubbles using the Colon Endoscopic Bubble Scale (CEBuS), ADR, CIR, and the intra-procedural use of simethicone were recorded. Results: We included 191 and 197 patients in the PEG + simethicone group and the PEG group, respectively. When comparing the PEG + simethicone group versus the PEG group, no significant differences in adequate bowel preparation rates (97%vs. 93%; p = 0.11) were found. However, the bubble scale score was significantly lower in the PEG + simethicone group (0 [0] versus 2 [5], p < 0.01), as well as intraprocedural use of simethicone (7% vs. 37%; p < 0.01). ADR (62% vs. 61%; p = 0.86) and CIR (98% vs. 96%, p = 0.14) did not differ between both groups. Conclusion: Adding oral simethicone to a split-bowel preparation resulted in a lower incidence of bubbles and a lower intraprocedural use of simethicone but no further improvement on the preparation quality or ADR.
id RCAP_a13a5d702da855167af3253d6c700e5d
oai_identifier_str oai:scielo:S2341-45452024000200040
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled TrialColorectal cancerScreeningBowel preparationSimethiconeAbstract Introduction: Current guidelines suggest adding oral simethicone to bowel preparation for colonoscopy. However, its effect on key quality indicators for screening colonoscopy remains unclear. The primary aim was to assess the rate of adequate bowel preparation in split-dose high-volume polyethylene glycol (PEG), with or without simethicone. Methods: This is an endoscopist-blinded, randomized controlled trial, including patients scheduled for colonoscopy after a positive faecal immunochemical test. Patients were randomly assigned to 4 L of PEG split dose (PEG) or 4 L of PEG split dose plus 500 mg oral simethicone (PEG + simethicone). The Boston Bowel Preparation Scale (BBPS) score, the preparation quality regarding bubbles using the Colon Endoscopic Bubble Scale (CEBuS), ADR, CIR, and the intra-procedural use of simethicone were recorded. Results: We included 191 and 197 patients in the PEG + simethicone group and the PEG group, respectively. When comparing the PEG + simethicone group versus the PEG group, no significant differences in adequate bowel preparation rates (97%vs. 93%; p = 0.11) were found. However, the bubble scale score was significantly lower in the PEG + simethicone group (0 [0] versus 2 [5], p < 0.01), as well as intraprocedural use of simethicone (7% vs. 37%; p < 0.01). ADR (62% vs. 61%; p = 0.86) and CIR (98% vs. 96%, p = 0.14) did not differ between both groups. Conclusion: Adding oral simethicone to a split-bowel preparation resulted in a lower incidence of bubbles and a lower intraprocedural use of simethicone but no further improvement on the preparation quality or ADR.Sociedade Portuguesa de Gastrenterologia2024-04-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040GE-Portuguese Journal of Gastroenterology v.31 n.2 2024reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040João,MafaldaAreia,MiguelAlves,SusanaElvas,LuísBrito,DanielSaraiva,SandraCadime,Ana Teresainfo:eu-repo/semantics/openAccess2024-05-23T23:00:25Zoai:scielo:S2341-45452024000200040Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T17:52:11.318689Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
title The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
spellingShingle The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
João,Mafalda
Colorectal cancer
Screening
Bowel preparation
Simethicone
title_short The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
title_full The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
title_fullStr The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
title_full_unstemmed The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
title_sort The Effect of Oral Simethicone in a Bowel Preparation in a Colorectal Cancer Screening Colonoscopy Setting: A Randomized Controlled Trial
author João,Mafalda
author_facet João,Mafalda
Areia,Miguel
Alves,Susana
Elvas,Luís
Brito,Daniel
Saraiva,Sandra
Cadime,Ana Teresa
author_role author
author2 Areia,Miguel
Alves,Susana
Elvas,Luís
Brito,Daniel
Saraiva,Sandra
Cadime,Ana Teresa
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv João,Mafalda
Areia,Miguel
Alves,Susana
Elvas,Luís
Brito,Daniel
Saraiva,Sandra
Cadime,Ana Teresa
dc.subject.por.fl_str_mv Colorectal cancer
Screening
Bowel preparation
Simethicone
topic Colorectal cancer
Screening
Bowel preparation
Simethicone
description Abstract Introduction: Current guidelines suggest adding oral simethicone to bowel preparation for colonoscopy. However, its effect on key quality indicators for screening colonoscopy remains unclear. The primary aim was to assess the rate of adequate bowel preparation in split-dose high-volume polyethylene glycol (PEG), with or without simethicone. Methods: This is an endoscopist-blinded, randomized controlled trial, including patients scheduled for colonoscopy after a positive faecal immunochemical test. Patients were randomly assigned to 4 L of PEG split dose (PEG) or 4 L of PEG split dose plus 500 mg oral simethicone (PEG + simethicone). The Boston Bowel Preparation Scale (BBPS) score, the preparation quality regarding bubbles using the Colon Endoscopic Bubble Scale (CEBuS), ADR, CIR, and the intra-procedural use of simethicone were recorded. Results: We included 191 and 197 patients in the PEG + simethicone group and the PEG group, respectively. When comparing the PEG + simethicone group versus the PEG group, no significant differences in adequate bowel preparation rates (97%vs. 93%; p = 0.11) were found. However, the bubble scale score was significantly lower in the PEG + simethicone group (0 [0] versus 2 [5], p < 0.01), as well as intraprocedural use of simethicone (7% vs. 37%; p < 0.01). ADR (62% vs. 61%; p = 0.86) and CIR (98% vs. 96%, p = 0.14) did not differ between both groups. Conclusion: Adding oral simethicone to a split-bowel preparation resulted in a lower incidence of bubbles and a lower intraprocedural use of simethicone but no further improvement on the preparation quality or ADR.
publishDate 2024
dc.date.none.fl_str_mv 2024-04-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452024000200040
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Gastrenterologia
publisher.none.fl_str_mv Sociedade Portuguesa de Gastrenterologia
dc.source.none.fl_str_mv GE-Portuguese Journal of Gastroenterology v.31 n.2 2024
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833597023385812992