Towards the design of efficient nonbeacon-enabled ZigBee networks

Bibliographic Details
Main Author: Fernández-López, Helena
Publication Date: 2012
Other Authors: Afonso, José A., Correia, J.H., Simões, Ricardo
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/11110/306
Summary: This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks,and are valid to other scenarios and environments rather than hospitals.
id RCAP_9f6bf095cbe60fcee717dd61b2c773ac
oai_identifier_str oai:ciencipca.ipca.pt:11110/306
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Towards the design of efficient nonbeacon-enabled ZigBee networksRemote patient monitoringWireless sensor networkZigBeeIEEE 802.15.4This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks,and are valid to other scenarios and environments rather than hospitals.Authors would like to thank Dr. João Paulo Carmo for the valuable comments and Mr. Pedro Macedo for programming the simulations. They also want to thank Mr.Nélson Brito, Mr. Teófilo Leite and Ms. Teresa Moura, from Hospital Privado de Guimarães, for the encouragement and support. This work has been supported by the Portuguese Foundation for Science and Technology (FCT), Lisbon, through the 3o Quadro Comunitário de Apoio, the MITPortugal,POCTI and FEDER programs, project PEst-C/ CTM/LA0025/2011, and the FCT grant SFRH/BD/39408/2007. Clinical and financial support for the case-study has been provided by Grupo AMI – Assistência Médica Integral (Casa de Saúde Guimar~aes, SA), Portugal, under the partnership established between this healthcare company and the University of Minho.Computer Networks2013-11-20T18:17:28Z2012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/11110/306oai:ciencipca.ipca.pt:11110/306enghttp://hdl.handle.net/11110/306metadata only accessinfo:eu-repo/semantics/openAccessFernández-López, HelenaAfonso, José A.Correia, J.H.Simões, Ricardoreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2022-09-05T12:51:52Zoai:ciencipca.ipca.pt:11110/306Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T10:01:32.619635Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Towards the design of efficient nonbeacon-enabled ZigBee networks
title Towards the design of efficient nonbeacon-enabled ZigBee networks
spellingShingle Towards the design of efficient nonbeacon-enabled ZigBee networks
Fernández-López, Helena
Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
title_short Towards the design of efficient nonbeacon-enabled ZigBee networks
title_full Towards the design of efficient nonbeacon-enabled ZigBee networks
title_fullStr Towards the design of efficient nonbeacon-enabled ZigBee networks
title_full_unstemmed Towards the design of efficient nonbeacon-enabled ZigBee networks
title_sort Towards the design of efficient nonbeacon-enabled ZigBee networks
author Fernández-López, Helena
author_facet Fernández-López, Helena
Afonso, José A.
Correia, J.H.
Simões, Ricardo
author_role author
author2 Afonso, José A.
Correia, J.H.
Simões, Ricardo
author2_role author
author
author
dc.contributor.author.fl_str_mv Fernández-López, Helena
Afonso, José A.
Correia, J.H.
Simões, Ricardo
dc.subject.por.fl_str_mv Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
topic Remote patient monitoring
Wireless sensor network
ZigBee
IEEE 802.15.4
description This paper presents experimental results of the communication performance evaluation of a prototype ZigBee-based patient monitoring system commissioned in an in-patient floor of a Portuguese hospital (HPG – Hospital Privado de Guimar~aes). Besides, it revisits relevant problems that affect the performance of nonbeacon-enabled ZigBee networks. Initially, the presence of hidden-nodes and the impact of sensor node mobility are discussed. It was observed, for instance, that the message delivery ratio in a star network consisting of six wireless electrocardiogram sensor devices may decrease from 100% when no hidden-nodes are present to 83.96% when half of the sensor devices are unable to detect the transmissions made by the other half. An additional aspect which affects the communication reliability is a deadlock condition that can occur if routers are unable to process incoming packets during the backoff part of the CSMA-CA mechanism. A simple approach to increase the message delivery ratio in this case is proposed and its effectiveness is verified. The discussion and results presented in this paper aim to contribute to the design of efficient networks,and are valid to other scenarios and environments rather than hospitals.
publishDate 2012
dc.date.none.fl_str_mv 2012-01-01T00:00:00Z
2013-11-20T18:17:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/11110/306
oai:ciencipca.ipca.pt:11110/306
url http://hdl.handle.net/11110/306
identifier_str_mv oai:ciencipca.ipca.pt:11110/306
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://hdl.handle.net/11110/306
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Computer Networks
publisher.none.fl_str_mv Computer Networks
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833590380526829568