Export Ready — 

Long-term electrode–skin impedance variation for electromyographic measurements

Bibliographic Details
Main Author: Sousa, Andreia S. P.
Publication Date: 2023
Other Authors: Noites, Andreia, Vilarinho, Rui, Santos, Rubim
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.22/23803
Summary: This study aims to observe the evolution of the electrode–skin interface impedance of surface EMG electrodes over the time taken to determine the time of stabilization. Eight healthy subjects participated in the study. Electrode–skin impedance was evaluated in the rectus abdominal muscle every five minutes, over a total period of 50 min. A reduction of 13.23% in the impedance values was observed in minute 10 (p = 0.007), and a reduction of 9.02% was observed in minute 15 (p = 0.029). No statistically significant differences were observed in the other instants evaluated. The findings obtained in the present study demonstrate a decrease in electrode–skin impedance from minute 5 to minute 15, followed by a stabilization period with a low percentage of variation till minute 50.
id RCAP_9b28f17f3ad9b4c300917343b7cf75c5
oai_identifier_str oai:recipp.ipp.pt:10400.22/23803
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Long-term electrode–skin impedance variation for electromyographic measurementsElectrode–skin impedanceElectromyographyStabilityThis study aims to observe the evolution of the electrode–skin interface impedance of surface EMG electrodes over the time taken to determine the time of stabilization. Eight healthy subjects participated in the study. Electrode–skin impedance was evaluated in the rectus abdominal muscle every five minutes, over a total period of 50 min. A reduction of 13.23% in the impedance values was observed in minute 10 (p = 0.007), and a reduction of 9.02% was observed in minute 15 (p = 0.029). No statistically significant differences were observed in the other instants evaluated. The findings obtained in the present study demonstrate a decrease in electrode–skin impedance from minute 5 to minute 15, followed by a stabilization period with a low percentage of variation till minute 50.MDPIREPOSITÓRIO P.PORTOSousa, Andreia S. P.Noites, AndreiaVilarinho, RuiSantos, Rubim2023-10-27T15:14:22Z2023-10-192023-10-19T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/23803eng10.3390/s23208582info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-07T10:22:34Zoai:recipp.ipp.pt:10400.22/23803Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:51:06.291467Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Long-term electrode–skin impedance variation for electromyographic measurements
title Long-term electrode–skin impedance variation for electromyographic measurements
spellingShingle Long-term electrode–skin impedance variation for electromyographic measurements
Sousa, Andreia S. P.
Electrode–skin impedance
Electromyography
Stability
title_short Long-term electrode–skin impedance variation for electromyographic measurements
title_full Long-term electrode–skin impedance variation for electromyographic measurements
title_fullStr Long-term electrode–skin impedance variation for electromyographic measurements
title_full_unstemmed Long-term electrode–skin impedance variation for electromyographic measurements
title_sort Long-term electrode–skin impedance variation for electromyographic measurements
author Sousa, Andreia S. P.
author_facet Sousa, Andreia S. P.
Noites, Andreia
Vilarinho, Rui
Santos, Rubim
author_role author
author2 Noites, Andreia
Vilarinho, Rui
Santos, Rubim
author2_role author
author
author
dc.contributor.none.fl_str_mv REPOSITÓRIO P.PORTO
dc.contributor.author.fl_str_mv Sousa, Andreia S. P.
Noites, Andreia
Vilarinho, Rui
Santos, Rubim
dc.subject.por.fl_str_mv Electrode–skin impedance
Electromyography
Stability
topic Electrode–skin impedance
Electromyography
Stability
description This study aims to observe the evolution of the electrode–skin interface impedance of surface EMG electrodes over the time taken to determine the time of stabilization. Eight healthy subjects participated in the study. Electrode–skin impedance was evaluated in the rectus abdominal muscle every five minutes, over a total period of 50 min. A reduction of 13.23% in the impedance values was observed in minute 10 (p = 0.007), and a reduction of 9.02% was observed in minute 15 (p = 0.029). No statistically significant differences were observed in the other instants evaluated. The findings obtained in the present study demonstrate a decrease in electrode–skin impedance from minute 5 to minute 15, followed by a stabilization period with a low percentage of variation till minute 50.
publishDate 2023
dc.date.none.fl_str_mv 2023-10-27T15:14:22Z
2023-10-19
2023-10-19T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/23803
url http://hdl.handle.net/10400.22/23803
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.3390/s23208582
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600723903840256