Predictors of functional capacity in patients with pulmonary hypertension
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10451/34242 |
Summary: | © 2015 Plácido R, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
id |
RCAP_93d3c8dadbb34a375d1613dc2d7c8f8b |
---|---|
oai_identifier_str |
oai:repositorio.ulisboa.pt:10451/34242 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Predictors of functional capacity in patients with pulmonary hypertensionPulmonary hypertension6-Minute walk testBiomarkersEchocardiographyPrognosis© 2015 Plácido R, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Introduction: The 6-minute walk test (6 MWT) distance is frequently used in the prediction of pulmonary hypertension (PH) prognosis. However, potential surrogates of this measure have not been established. We aim to describe the clinical, echocardiographic, and laboratorial criteria determining the 6 MWT distance in patients with PH. Methods: In 22 consecutive PH patients, functional capacity was evaluated by the 6 MWT distance and compared with levels of neurohormonal activation biomarkers and echocardiographic parameters for right ventricular (RV) function. Results: A correlation between the 6 MWT distance and several clinical parameters was found: Borg’s pre-test classification (R=-0.46; p=0.038); WHO functional class (p=0.029). Patients with higher levels of aldosterone (R=-0.46; p=0.030), renin (R=-0.43; p=0.046) and mid-regional pro-adrenomedullin (MR-proADM, R=-0.53; p=0.009) had worse 6 MWT performance. The opposite was true for natremia levels (R=0.55; p=0.006). There was a positive correlation between the 6 MWT distance and RV global longitudinal peak systolic strain rate and early diastolic strain rate (R=0.49; p=0.038 and R=-0.55; p=0.018, respectively). On multivariate analysis, only natremia and early diastolic strain rate were predictors of the 6 MWT distance. Conclusion: The 6 MWT distance correlated with renin-angiotensin-aldosterone system activation and parameters for RV myocardial deformation. The new biomarker MR-proADM proved to be useful in the prediction of the functional capacity.OMICS InternationalRepositório da Universidade de LisboaPlácido, RuiMartins, SusanaMarques, João SilvaKovell, LaraGonçalves, SusanaAlmeida, Ana G.Diogo, António NunesPinto, Fausto J.2018-07-18T14:53:50Z20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10451/34242engJ Pulm Respir Med 5: 2902161-105X10.4172/2161-105X.1000290info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-17T13:56:17Zoai:repositorio.ulisboa.pt:10451/34242Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T02:58:38.698355Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Predictors of functional capacity in patients with pulmonary hypertension |
title |
Predictors of functional capacity in patients with pulmonary hypertension |
spellingShingle |
Predictors of functional capacity in patients with pulmonary hypertension Plácido, Rui Pulmonary hypertension 6-Minute walk test Biomarkers Echocardiography Prognosis |
title_short |
Predictors of functional capacity in patients with pulmonary hypertension |
title_full |
Predictors of functional capacity in patients with pulmonary hypertension |
title_fullStr |
Predictors of functional capacity in patients with pulmonary hypertension |
title_full_unstemmed |
Predictors of functional capacity in patients with pulmonary hypertension |
title_sort |
Predictors of functional capacity in patients with pulmonary hypertension |
author |
Plácido, Rui |
author_facet |
Plácido, Rui Martins, Susana Marques, João Silva Kovell, Lara Gonçalves, Susana Almeida, Ana G. Diogo, António Nunes Pinto, Fausto J. |
author_role |
author |
author2 |
Martins, Susana Marques, João Silva Kovell, Lara Gonçalves, Susana Almeida, Ana G. Diogo, António Nunes Pinto, Fausto J. |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório da Universidade de Lisboa |
dc.contributor.author.fl_str_mv |
Plácido, Rui Martins, Susana Marques, João Silva Kovell, Lara Gonçalves, Susana Almeida, Ana G. Diogo, António Nunes Pinto, Fausto J. |
dc.subject.por.fl_str_mv |
Pulmonary hypertension 6-Minute walk test Biomarkers Echocardiography Prognosis |
topic |
Pulmonary hypertension 6-Minute walk test Biomarkers Echocardiography Prognosis |
description |
© 2015 Plácido R, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 2015-01-01T00:00:00Z 2018-07-18T14:53:50Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10451/34242 |
url |
http://hdl.handle.net/10451/34242 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
J Pulm Respir Med 5: 290 2161-105X 10.4172/2161-105X.1000290 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
OMICS International |
publisher.none.fl_str_mv |
OMICS International |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833601549516931072 |