Export Ready — 

Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions

Bibliographic Details
Main Author: Ribeiro, Ana
Publication Date: 2005
Other Authors: Rocha, L. A., Ariza, E., Celis, J. P.
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/1822/5818
Summary: The demand for metallic materials in medical and dental devices is large; metals and alloys are widely used as biomedical materials and are indispensable in the medical field. In particular, toughness, elasticity, rigidity, and, some times, electrical conductivity are essential properties for metallic materials used in medical devices. In dentistry, titanium is used for restorations, orthodontic wires, and dental implants. Materials implanted in the human body are intermittently stressed with loads, which are repeated in a tremendous amount of cycles. During mastication, dental implants are simultaneously subjected to corrosion by the oral environment and to the sliding-wear process by bite forces. Dental wear can be attributed to mastication where the teeth are worn by attrition and abrasion. The main aim of the present study was to investigate the tribocorrosion behaviour of titanium grade 2 in reciprocating sliding conditions in contact with artificial saliva solutions. Particular attention is given to the relationship between mechanical damage and the electrochemical behaviour of the material. Sliding-corrosion experiments were performed using a reciprocating ball-on-flat contact configuration and the open circuit potential was monitored during the test. Also electrochemical impedance spectroscopy was used to obtain a more detailed description of the corrosion mechanisms and to characterise the passive layer that forms on the titanium surface. To reproduce the oral environment around the dental implant, some additives (citric acid, anodic, cathodic and organic inhibitors) were added to simple artificial saliva constituted mainly by NaCl and KCl, and with a pH between 5 and 7. A corundum ball was loaded on the top of the flat rectangular sample at a normal force of 10N. Linear peak-to-peak displacement amplitude of 3 mm at vibrating frequencies of 1 Hz was applied to the tribocorrosion system. The tests were performed for 11160 cycles. The surface roughness and topography of the titanium samples were evaluated prior to testing. In relation to the friction profile, for all solutions, no significant differences were observed. In fact, the aqueous environment used doesn’t have sufficient viscosity to cause changes in the friction behavior. Regarding the weight loss results it is possible to conclude that titanium in artificial saliva solution with citric acid present the high weight lost. Additionally, cathodic and organic inhibitors solutions exposed a higher tendency for corrosion, forming an oxide passive film with lower protection characteristics.
id RCAP_9083068cba1b8dccbb6b5935b01f9132
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/5818
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutionsTribocorrosionDental implantsThe demand for metallic materials in medical and dental devices is large; metals and alloys are widely used as biomedical materials and are indispensable in the medical field. In particular, toughness, elasticity, rigidity, and, some times, electrical conductivity are essential properties for metallic materials used in medical devices. In dentistry, titanium is used for restorations, orthodontic wires, and dental implants. Materials implanted in the human body are intermittently stressed with loads, which are repeated in a tremendous amount of cycles. During mastication, dental implants are simultaneously subjected to corrosion by the oral environment and to the sliding-wear process by bite forces. Dental wear can be attributed to mastication where the teeth are worn by attrition and abrasion. The main aim of the present study was to investigate the tribocorrosion behaviour of titanium grade 2 in reciprocating sliding conditions in contact with artificial saliva solutions. Particular attention is given to the relationship between mechanical damage and the electrochemical behaviour of the material. Sliding-corrosion experiments were performed using a reciprocating ball-on-flat contact configuration and the open circuit potential was monitored during the test. Also electrochemical impedance spectroscopy was used to obtain a more detailed description of the corrosion mechanisms and to characterise the passive layer that forms on the titanium surface. To reproduce the oral environment around the dental implant, some additives (citric acid, anodic, cathodic and organic inhibitors) were added to simple artificial saliva constituted mainly by NaCl and KCl, and with a pH between 5 and 7. A corundum ball was loaded on the top of the flat rectangular sample at a normal force of 10N. Linear peak-to-peak displacement amplitude of 3 mm at vibrating frequencies of 1 Hz was applied to the tribocorrosion system. The tests were performed for 11160 cycles. The surface roughness and topography of the titanium samples were evaluated prior to testing. In relation to the friction profile, for all solutions, no significant differences were observed. In fact, the aqueous environment used doesn’t have sufficient viscosity to cause changes in the friction behavior. Regarding the weight loss results it is possible to conclude that titanium in artificial saliva solution with citric acid present the high weight lost. Additionally, cathodic and organic inhibitors solutions exposed a higher tendency for corrosion, forming an oxide passive film with lower protection characteristics.Universidade do MinhoRibeiro, AnaRocha, L. A.Ariza, E.Celis, J. P.2005-092005-09-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/5818engEUROPEAN CORROSION CONGRESS, Lisboa, 2005 - "EUROCORR 2005 : European Corrosion Congress : Proceedings". [S.l. : s.n., 2005].info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T06:40:54Zoai:repositorium.sdum.uminho.pt:1822/5818Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:00:55.631514Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
title Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
spellingShingle Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
Ribeiro, Ana
Tribocorrosion
Dental implants
title_short Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
title_full Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
title_fullStr Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
title_full_unstemmed Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
title_sort Tribocorrosion behaviour of titanium grade 2 in alternative linear regime of sliding in artificial saliva solutions
author Ribeiro, Ana
author_facet Ribeiro, Ana
Rocha, L. A.
Ariza, E.
Celis, J. P.
author_role author
author2 Rocha, L. A.
Ariza, E.
Celis, J. P.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Ribeiro, Ana
Rocha, L. A.
Ariza, E.
Celis, J. P.
dc.subject.por.fl_str_mv Tribocorrosion
Dental implants
topic Tribocorrosion
Dental implants
description The demand for metallic materials in medical and dental devices is large; metals and alloys are widely used as biomedical materials and are indispensable in the medical field. In particular, toughness, elasticity, rigidity, and, some times, electrical conductivity are essential properties for metallic materials used in medical devices. In dentistry, titanium is used for restorations, orthodontic wires, and dental implants. Materials implanted in the human body are intermittently stressed with loads, which are repeated in a tremendous amount of cycles. During mastication, dental implants are simultaneously subjected to corrosion by the oral environment and to the sliding-wear process by bite forces. Dental wear can be attributed to mastication where the teeth are worn by attrition and abrasion. The main aim of the present study was to investigate the tribocorrosion behaviour of titanium grade 2 in reciprocating sliding conditions in contact with artificial saliva solutions. Particular attention is given to the relationship between mechanical damage and the electrochemical behaviour of the material. Sliding-corrosion experiments were performed using a reciprocating ball-on-flat contact configuration and the open circuit potential was monitored during the test. Also electrochemical impedance spectroscopy was used to obtain a more detailed description of the corrosion mechanisms and to characterise the passive layer that forms on the titanium surface. To reproduce the oral environment around the dental implant, some additives (citric acid, anodic, cathodic and organic inhibitors) were added to simple artificial saliva constituted mainly by NaCl and KCl, and with a pH between 5 and 7. A corundum ball was loaded on the top of the flat rectangular sample at a normal force of 10N. Linear peak-to-peak displacement amplitude of 3 mm at vibrating frequencies of 1 Hz was applied to the tribocorrosion system. The tests were performed for 11160 cycles. The surface roughness and topography of the titanium samples were evaluated prior to testing. In relation to the friction profile, for all solutions, no significant differences were observed. In fact, the aqueous environment used doesn’t have sufficient viscosity to cause changes in the friction behavior. Regarding the weight loss results it is possible to conclude that titanium in artificial saliva solution with citric acid present the high weight lost. Additionally, cathodic and organic inhibitors solutions exposed a higher tendency for corrosion, forming an oxide passive film with lower protection characteristics.
publishDate 2005
dc.date.none.fl_str_mv 2005-09
2005-09-01T00:00:00Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/5818
url http://hdl.handle.net/1822/5818
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv EUROPEAN CORROSION CONGRESS, Lisboa, 2005 - "EUROCORR 2005 : European Corrosion Congress : Proceedings". [S.l. : s.n., 2005].
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595683809001472