Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products

Bibliographic Details
Main Author: Habib,I.H.I.
Publication Date: 2008
Other Authors: Weshahy,S.A., Toubar,S., El-Alamin,M.M.A.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001
Summary: Cathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%.
id RCAP_8cc361b83db09e2022bd695cefa187fd
oai_identifier_str oai:scielo:S0872-19042008000400001
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Productslosartanadsorptive stripping voltammetryHMDEstabilityCathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%.Sociedade Portuguesa de Electroquímica2008-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001Portugaliae Electrochimica Acta v.26 n.4 2008reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001Habib,I.H.I.Weshahy,S.A.Toubar,S.El-Alamin,M.M.A.info:eu-repo/semantics/openAccess2024-02-06T17:06:55Zoai:scielo:S0872-19042008000400001Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:56:21.748903Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
title Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
spellingShingle Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
Habib,I.H.I.
losartan
adsorptive stripping voltammetry
HMDE
stability
title_short Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
title_full Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
title_fullStr Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
title_full_unstemmed Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
title_sort Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
author Habib,I.H.I.
author_facet Habib,I.H.I.
Weshahy,S.A.
Toubar,S.
El-Alamin,M.M.A.
author_role author
author2 Weshahy,S.A.
Toubar,S.
El-Alamin,M.M.A.
author2_role author
author
author
dc.contributor.author.fl_str_mv Habib,I.H.I.
Weshahy,S.A.
Toubar,S.
El-Alamin,M.M.A.
dc.subject.por.fl_str_mv losartan
adsorptive stripping voltammetry
HMDE
stability
topic losartan
adsorptive stripping voltammetry
HMDE
stability
description Cathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
dc.source.none.fl_str_mv Portugaliae Electrochimica Acta v.26 n.4 2008
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833593266648383488