Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , , , , , |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.21/5025 |
Summary: | This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice. |
id |
RCAP_8ca6a2c1da9ecf61760f163a0a65b030 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/5025 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiographyComputed radiographyOptimisationSpinal curvature measurementsEffective doseImage qualityPaediatric patientsPhantomThis review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.Open Source, University of SalfordRCIPLReis, CláudiaNdlovu, JuniorSerrenho, CatarinaAkhtar, Ifrahde Haan, SeraphineGarcia, José Antóniode Linde, DanielThorskog, MartineFranco, LorisHogg, Peter2015-08-27T14:29:37Z20152015-01-01T00:00:00Zbook partinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.21/5025eng9781907842603info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-12T10:47:56Zoai:repositorio.ipl.pt:10400.21/5025Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T20:08:10.410261Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
title |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
spellingShingle |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography Reis, Cláudia Computed radiography Optimisation Spinal curvature measurements Effective dose Image quality Paediatric patients Phantom |
title_short |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
title_full |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
title_fullStr |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
title_full_unstemmed |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
title_sort |
Optimisation of exposure parameters for spinal curvature measurements in paediatric radiography |
author |
Reis, Cláudia |
author_facet |
Reis, Cláudia Ndlovu, Junior Serrenho, Catarina Akhtar, Ifrah de Haan, Seraphine Garcia, José António de Linde, Daniel Thorskog, Martine Franco, Loris Hogg, Peter |
author_role |
author |
author2 |
Ndlovu, Junior Serrenho, Catarina Akhtar, Ifrah de Haan, Seraphine Garcia, José António de Linde, Daniel Thorskog, Martine Franco, Loris Hogg, Peter |
author2_role |
author author author author author author author author author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Reis, Cláudia Ndlovu, Junior Serrenho, Catarina Akhtar, Ifrah de Haan, Seraphine Garcia, José António de Linde, Daniel Thorskog, Martine Franco, Loris Hogg, Peter |
dc.subject.por.fl_str_mv |
Computed radiography Optimisation Spinal curvature measurements Effective dose Image quality Paediatric patients Phantom |
topic |
Computed radiography Optimisation Spinal curvature measurements Effective dose Image quality Paediatric patients Phantom |
description |
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08-27T14:29:37Z 2015 2015-01-01T00:00:00Z |
dc.type.driver.fl_str_mv |
book part |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/5025 |
url |
http://hdl.handle.net/10400.21/5025 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
9781907842603 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Open Source, University of Salford |
publisher.none.fl_str_mv |
Open Source, University of Salford |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833598509746487296 |