Unusual solutions for catheter placement in haemodialysis patients
Main Author: | |
---|---|
Publication Date: | 2013 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008 |
Summary: | Background:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery. |
id |
RCAP_8c7dfc30e1d7c7c8acd22a99034909cc |
---|---|
oai_identifier_str |
oai:scielo:S0872-01692013000100008 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Unusual solutions for catheter placement in haemodialysis patientsCathetershaemodialysisvascular access failureBackground:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.Sociedade Portuguesa de Nefrologia2013-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008Portuguese Journal of Nephrology & Hypertension v.27 n.1 2013reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008Caeiro,FernandoCarvalho,DulceBrum,SandraNolasco,Fernandoinfo:eu-repo/semantics/openAccess2024-02-06T17:04:41Zoai:scielo:S0872-01692013000100008Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:54:20.770421Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Unusual solutions for catheter placement in haemodialysis patients |
title |
Unusual solutions for catheter placement in haemodialysis patients |
spellingShingle |
Unusual solutions for catheter placement in haemodialysis patients Caeiro,Fernando Catheters haemodialysis vascular access failure |
title_short |
Unusual solutions for catheter placement in haemodialysis patients |
title_full |
Unusual solutions for catheter placement in haemodialysis patients |
title_fullStr |
Unusual solutions for catheter placement in haemodialysis patients |
title_full_unstemmed |
Unusual solutions for catheter placement in haemodialysis patients |
title_sort |
Unusual solutions for catheter placement in haemodialysis patients |
author |
Caeiro,Fernando |
author_facet |
Caeiro,Fernando Carvalho,Dulce Brum,Sandra Nolasco,Fernando |
author_role |
author |
author2 |
Carvalho,Dulce Brum,Sandra Nolasco,Fernando |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Caeiro,Fernando Carvalho,Dulce Brum,Sandra Nolasco,Fernando |
dc.subject.por.fl_str_mv |
Catheters haemodialysis vascular access failure |
topic |
Catheters haemodialysis vascular access failure |
description |
Background:Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692013000100008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Nefrologia |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Nefrologia |
dc.source.none.fl_str_mv |
Portuguese Journal of Nephrology & Hypertension v.27 n.1 2013 reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833593234483314688 |