Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study

Bibliographic Details
Main Author: Moura-Coelho, Nuno
Publication Date: 2023
Other Authors: Papa-Vettorazzi, Renato, Santiesteban-García, Imalvet, Dias-Santos, Arnaldo, Manero, Felicidad, Cunha, João Paulo, Güell, José
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.21/15568
Summary: The aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a retrospective, single-surgeon case series of eyes that developed post-DMEK vs-CMO performed between January 2011 and December 2020. Data collected included: indication for DMEK; biometric data; ocular comorbidities; past medical history; time to detection of vs-CMO after DMEK (T, weeks); best-corrected visual acuity (BCVA, logMAR) and central retinal thickness (CRT, µm) at diagnosis of vs-CMO, after resolution of CMO, and at last follow-up; and management strategy. The main outcomes analyzed were the incidence of vs-CMO and improvement in BCVA and CRT after treatment of vs-CMO. Of 291 consecutive DMEK surgeries, 14 eyes of 13 patients (4.8%) developed vs-CMO. Five patients (38.5%) had a history of CMO, and 28.6% of eyes had ophthalmic comorbidities. Median (P25-P75) T was 4 (3-10) weeks. Treatment success was observed in 12/13 eyes (92.3%), two of which required second-line treatment. In successful cases (median time-to-resolution 3.0 (2.0-3.5) months), median BCVA improved from 0.60 (0.40-0.80) logMAR to 0.30 (0.15-0.40) logMAR (p = 0.002) after treatment, and median CRT improved from 582.5 (400.0-655.0) µm to 278.0 (258.0-294.0) µm (p = 0.005). In our study, we found a 4.8% rate of post-DMEK vs-CMO, with most cases occurring in the first 3 months after surgery. Good functional and anatomical outcomes are expected in most eyes, without treatment-related complications or implications in graft outcomes. Additional studies are encouraged to determine a standardized protocol for post-DMEK vs-CMO.
id RCAP_8b7d1e36369e2ce77d1b3233104b728a
oai_identifier_str oai:repositorio.ipl.pt:10400.21/15568
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective studyOphthalmologyDescemet membraneDescemet stripping endothelial keratoplastyCorneal endotheliumTransplantationFuchs' endothelial dystrophyMacular edemaSpainThe aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a retrospective, single-surgeon case series of eyes that developed post-DMEK vs-CMO performed between January 2011 and December 2020. Data collected included: indication for DMEK; biometric data; ocular comorbidities; past medical history; time to detection of vs-CMO after DMEK (T, weeks); best-corrected visual acuity (BCVA, logMAR) and central retinal thickness (CRT, µm) at diagnosis of vs-CMO, after resolution of CMO, and at last follow-up; and management strategy. The main outcomes analyzed were the incidence of vs-CMO and improvement in BCVA and CRT after treatment of vs-CMO. Of 291 consecutive DMEK surgeries, 14 eyes of 13 patients (4.8%) developed vs-CMO. Five patients (38.5%) had a history of CMO, and 28.6% of eyes had ophthalmic comorbidities. Median (P25-P75) T was 4 (3-10) weeks. Treatment success was observed in 12/13 eyes (92.3%), two of which required second-line treatment. In successful cases (median time-to-resolution 3.0 (2.0-3.5) months), median BCVA improved from 0.60 (0.40-0.80) logMAR to 0.30 (0.15-0.40) logMAR (p = 0.002) after treatment, and median CRT improved from 582.5 (400.0-655.0) µm to 278.0 (258.0-294.0) µm (p = 0.005). In our study, we found a 4.8% rate of post-DMEK vs-CMO, with most cases occurring in the first 3 months after surgery. Good functional and anatomical outcomes are expected in most eyes, without treatment-related complications or implications in graft outcomes. Additional studies are encouraged to determine a standardized protocol for post-DMEK vs-CMO.Springer NatureRCIPLMoura-Coelho, NunoPapa-Vettorazzi, RenatoSantiesteban-García, ImalvetDias-Santos, ArnaldoManero, FelicidadCunha, João PauloGüell, José2023-02-14T12:05:15Z2023-022023-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/15568eng10.1038/s41598-023-29127-5info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-12T08:08:59Zoai:repositorio.ipl.pt:10400.21/15568Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T19:53:59.496673Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
title Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
spellingShingle Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
Moura-Coelho, Nuno
Ophthalmology
Descemet membrane
Descemet stripping endothelial keratoplasty
Corneal endothelium
Transplantation
Fuchs' endothelial dystrophy
Macular edema
Spain
title_short Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
title_full Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
title_fullStr Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
title_full_unstemmed Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
title_sort Outcomes of cystoid macular edema following Descemet’s membrane endothelial keratoplasty in a referral center for keratoplasty in Spain: retrospective study
author Moura-Coelho, Nuno
author_facet Moura-Coelho, Nuno
Papa-Vettorazzi, Renato
Santiesteban-García, Imalvet
Dias-Santos, Arnaldo
Manero, Felicidad
Cunha, João Paulo
Güell, José
author_role author
author2 Papa-Vettorazzi, Renato
Santiesteban-García, Imalvet
Dias-Santos, Arnaldo
Manero, Felicidad
Cunha, João Paulo
Güell, José
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Moura-Coelho, Nuno
Papa-Vettorazzi, Renato
Santiesteban-García, Imalvet
Dias-Santos, Arnaldo
Manero, Felicidad
Cunha, João Paulo
Güell, José
dc.subject.por.fl_str_mv Ophthalmology
Descemet membrane
Descemet stripping endothelial keratoplasty
Corneal endothelium
Transplantation
Fuchs' endothelial dystrophy
Macular edema
Spain
topic Ophthalmology
Descemet membrane
Descemet stripping endothelial keratoplasty
Corneal endothelium
Transplantation
Fuchs' endothelial dystrophy
Macular edema
Spain
description The aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a retrospective, single-surgeon case series of eyes that developed post-DMEK vs-CMO performed between January 2011 and December 2020. Data collected included: indication for DMEK; biometric data; ocular comorbidities; past medical history; time to detection of vs-CMO after DMEK (T, weeks); best-corrected visual acuity (BCVA, logMAR) and central retinal thickness (CRT, µm) at diagnosis of vs-CMO, after resolution of CMO, and at last follow-up; and management strategy. The main outcomes analyzed were the incidence of vs-CMO and improvement in BCVA and CRT after treatment of vs-CMO. Of 291 consecutive DMEK surgeries, 14 eyes of 13 patients (4.8%) developed vs-CMO. Five patients (38.5%) had a history of CMO, and 28.6% of eyes had ophthalmic comorbidities. Median (P25-P75) T was 4 (3-10) weeks. Treatment success was observed in 12/13 eyes (92.3%), two of which required second-line treatment. In successful cases (median time-to-resolution 3.0 (2.0-3.5) months), median BCVA improved from 0.60 (0.40-0.80) logMAR to 0.30 (0.15-0.40) logMAR (p = 0.002) after treatment, and median CRT improved from 582.5 (400.0-655.0) µm to 278.0 (258.0-294.0) µm (p = 0.005). In our study, we found a 4.8% rate of post-DMEK vs-CMO, with most cases occurring in the first 3 months after surgery. Good functional and anatomical outcomes are expected in most eyes, without treatment-related complications or implications in graft outcomes. Additional studies are encouraged to determine a standardized protocol for post-DMEK vs-CMO.
publishDate 2023
dc.date.none.fl_str_mv 2023-02-14T12:05:15Z
2023-02
2023-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/15568
url http://hdl.handle.net/10400.21/15568
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1038/s41598-023-29127-5
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Springer Nature
publisher.none.fl_str_mv Springer Nature
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833598384390275072