First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain
Main Author: | |
---|---|
Publication Date: | 2018 |
Other Authors: | , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10314/4178 https://doi.org/10.1039/c7ay02602a |
Summary: | A new high-performance liquid chromatography-diode-array detection (HPLC-DAD) method is herein reported for the first time for the simultaneous determination of three antiepileptic drugs (AEDs) [levetiracetam (LEV), zonisamide (ZNS) and lamotrigine (LTG)] and two convulsant agents [pentylenetetrazole (PTZ) and pilocarpine (PIL)] in rat plasma and brain matrices. Chromatographic separation of all analytes and 7-hydroxycoumarin, used as internal standard (IS), was achieved in less than 19 min on a C18 column maintained at 30 C using a mobile phase composed of acetonitrile (7.5%) and a mixture (92.5%) of water–triethylamine (99.5 : 0.05, v/v, pH 6.4) pumped at a flow rate of 1 mL min 1. The analytes and the IS were detected at 205, 215 or 240 nm. This method showed to be selective and the calibration curves were linear (r2 $ 0.991) over the concentration ranges of 0.4–100 mg mL 1 for LEV, 2–100 mg mL 1 for PTZ, 0.75–100 mg mL 1 for PIL, 0.15–100 mg mL 1 for ZNS and 0.3–50 mg mL 1 for LTG in both rat matrices. The overall data of precision and accuracy were in accordance with international guidelines on bioanalytical method validation. The analytes were extracted from the rat matrices by a liquid–liquid extraction procedure and the absolute recovery of the analytes was precise and reproducible. Additionally, this novel HPLC-DAD method was applied in a preliminary pharmacokinetic study in rats, which involved the target AEDs and convulsant agents, demonstrating to be a useful bioanalytical tool to support future non-clinical studies. |
id |
RCAP_8b43291b59e9ff6e09a4c0e13bd85d8c |
---|---|
oai_identifier_str |
oai:bdigital.ipg.pt:10314/4178 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brainFirst HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brainA new high-performance liquid chromatography-diode-array detection (HPLC-DAD) method is herein reported for the first time for the simultaneous determination of three antiepileptic drugs (AEDs) [levetiracetam (LEV), zonisamide (ZNS) and lamotrigine (LTG)] and two convulsant agents [pentylenetetrazole (PTZ) and pilocarpine (PIL)] in rat plasma and brain matrices. Chromatographic separation of all analytes and 7-hydroxycoumarin, used as internal standard (IS), was achieved in less than 19 min on a C18 column maintained at 30 C using a mobile phase composed of acetonitrile (7.5%) and a mixture (92.5%) of water–triethylamine (99.5 : 0.05, v/v, pH 6.4) pumped at a flow rate of 1 mL min 1. The analytes and the IS were detected at 205, 215 or 240 nm. This method showed to be selective and the calibration curves were linear (r2 $ 0.991) over the concentration ranges of 0.4–100 mg mL 1 for LEV, 2–100 mg mL 1 for PTZ, 0.75–100 mg mL 1 for PIL, 0.15–100 mg mL 1 for ZNS and 0.3–50 mg mL 1 for LTG in both rat matrices. The overall data of precision and accuracy were in accordance with international guidelines on bioanalytical method validation. The analytes were extracted from the rat matrices by a liquid–liquid extraction procedure and the absolute recovery of the analytes was precise and reproducible. Additionally, this novel HPLC-DAD method was applied in a preliminary pharmacokinetic study in rats, which involved the target AEDs and convulsant agents, demonstrating to be a useful bioanalytical tool to support future non-clinical studies.Analytical Methods2018-08-03T15:00:12Z2018-08-032018-01-31T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10314/4178http://hdl.handle.net/10314/4178https://doi.org/10.1039/c7ay02602aeng1759-9679Fonseca, BeatrizRodrigues, MárcioAlves, Gilbertoinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-01-05T03:00:21Zoai:bdigital.ipg.pt:10314/4178Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T19:25:17.170812Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
spellingShingle |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain Fonseca, Beatriz First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title_short |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title_full |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title_fullStr |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title_full_unstemmed |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
title_sort |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
author |
Fonseca, Beatriz |
author_facet |
Fonseca, Beatriz Rodrigues, Márcio Alves, Gilberto |
author_role |
author |
author2 |
Rodrigues, Márcio Alves, Gilberto |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Fonseca, Beatriz Rodrigues, Márcio Alves, Gilberto |
dc.subject.por.fl_str_mv |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
topic |
First HPLC method for the simultaneous quantification of levetiracetam, zonisamide, lamotrigine, pentylenetetrazole and pilocarpine in rat plasma and brain |
description |
A new high-performance liquid chromatography-diode-array detection (HPLC-DAD) method is herein reported for the first time for the simultaneous determination of three antiepileptic drugs (AEDs) [levetiracetam (LEV), zonisamide (ZNS) and lamotrigine (LTG)] and two convulsant agents [pentylenetetrazole (PTZ) and pilocarpine (PIL)] in rat plasma and brain matrices. Chromatographic separation of all analytes and 7-hydroxycoumarin, used as internal standard (IS), was achieved in less than 19 min on a C18 column maintained at 30 C using a mobile phase composed of acetonitrile (7.5%) and a mixture (92.5%) of water–triethylamine (99.5 : 0.05, v/v, pH 6.4) pumped at a flow rate of 1 mL min 1. The analytes and the IS were detected at 205, 215 or 240 nm. This method showed to be selective and the calibration curves were linear (r2 $ 0.991) over the concentration ranges of 0.4–100 mg mL 1 for LEV, 2–100 mg mL 1 for PTZ, 0.75–100 mg mL 1 for PIL, 0.15–100 mg mL 1 for ZNS and 0.3–50 mg mL 1 for LTG in both rat matrices. The overall data of precision and accuracy were in accordance with international guidelines on bioanalytical method validation. The analytes were extracted from the rat matrices by a liquid–liquid extraction procedure and the absolute recovery of the analytes was precise and reproducible. Additionally, this novel HPLC-DAD method was applied in a preliminary pharmacokinetic study in rats, which involved the target AEDs and convulsant agents, demonstrating to be a useful bioanalytical tool to support future non-clinical studies. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-08-03T15:00:12Z 2018-08-03 2018-01-31T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10314/4178 http://hdl.handle.net/10314/4178 https://doi.org/10.1039/c7ay02602a |
url |
http://hdl.handle.net/10314/4178 https://doi.org/10.1039/c7ay02602a |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1759-9679 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Analytical Methods |
publisher.none.fl_str_mv |
Analytical Methods |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833598085966594048 |