Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project

Detalhes bibliográficos
Autor(a) principal: Cano, Manuela
Data de Publicação: 2012
Outros Autores: Nogueira, Susana, Papoila, Ana Luísa, Aguiar, Fátima, Martins, Pedro, Marques, João, Caires, Iolanda, Martins, José, Pedro, Catarina, Paixão, Paulo, Rosado-Pinto, José, Leiria-Pinto, Paula, Aelenei, Daniel, Mendes, Ana, Teixeira, João Paulo, Proença, Carmo, Neuparth, Nuno
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://hdl.handle.net/10400.18/1107
Resumo: This paper describes field measurements of indoor air quality (IAQ) parameters, performed in 19 Portuguese Children Day Care Centers (CDCC) during the springtime of 2011 and aims to characterize the indoor environment. The results demonstrate an association between carbon dioxide and bacterial concentrations, which in turn are affected by the number of children present in each classroom. Indoor PM10 concentrations were higher than outdoor levels (I/O ratio>1) and was also found statistically significant association between PM10 concentrations and the type of floor covering materials. These results provide evidence that IAQ is inadequate and, as a consequence, human source contaminants such as bacteria and carbon dioxide accumulate indoors. This study suggests that it is necessary to improve ventilation in order to achieve a healthier indoor environment.
id RCAP_892e5d2ad9ee54ac779169efea331d02
oai_identifier_str oai:repositorio.insa.pt:10400.18/1107
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Indoor Air Quality in Portuguese Day Care Centers - ENVIRH ProjectIndoor Air QualityDay Care CentresExposure AssessmentAr e Saúde OcupacionalThis paper describes field measurements of indoor air quality (IAQ) parameters, performed in 19 Portuguese Children Day Care Centers (CDCC) during the springtime of 2011 and aims to characterize the indoor environment. The results demonstrate an association between carbon dioxide and bacterial concentrations, which in turn are affected by the number of children present in each classroom. Indoor PM10 concentrations were higher than outdoor levels (I/O ratio>1) and was also found statistically significant association between PM10 concentrations and the type of floor covering materials. These results provide evidence that IAQ is inadequate and, as a consequence, human source contaminants such as bacteria and carbon dioxide accumulate indoors. This study suggests that it is necessary to improve ventilation in order to achieve a healthier indoor environment.Dr Zhiqiang (John) Zhai, University of Colorado at Boulder, Dr. Xiangli Li, Dalian University of Technology ans Haidong Wang, University of Colorado at BoulderRepositório Científico do Instituto Nacional de SaúdeCano, ManuelaNogueira, SusanaPapoila, Ana LuísaAguiar, FátimaMartins, PedroMarques, JoãoCaires, IolandaMartins, JoséPedro, CatarinaPaixão, PauloRosado-Pinto, JoséLeiria-Pinto, PaulaAelenei, DanielMendes, AnaTeixeira, João PauloProença, CarmoNeuparth, Nuno2012-10-31T17:58:44Z2012-08-012012-08-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.18/1107eng978-0-9816881-9-0; 0-9816881-9-5info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-26T14:22:57Zoai:repositorio.insa.pt:10400.18/1107Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T21:37:30.697152Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
title Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
spellingShingle Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
Cano, Manuela
Indoor Air Quality
Day Care Centres
Exposure Assessment
Ar e Saúde Ocupacional
title_short Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
title_full Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
title_fullStr Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
title_full_unstemmed Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
title_sort Indoor Air Quality in Portuguese Day Care Centers - ENVIRH Project
author Cano, Manuela
author_facet Cano, Manuela
Nogueira, Susana
Papoila, Ana Luísa
Aguiar, Fátima
Martins, Pedro
Marques, João
Caires, Iolanda
Martins, José
Pedro, Catarina
Paixão, Paulo
Rosado-Pinto, José
Leiria-Pinto, Paula
Aelenei, Daniel
Mendes, Ana
Teixeira, João Paulo
Proença, Carmo
Neuparth, Nuno
author_role author
author2 Nogueira, Susana
Papoila, Ana Luísa
Aguiar, Fátima
Martins, Pedro
Marques, João
Caires, Iolanda
Martins, José
Pedro, Catarina
Paixão, Paulo
Rosado-Pinto, José
Leiria-Pinto, Paula
Aelenei, Daniel
Mendes, Ana
Teixeira, João Paulo
Proença, Carmo
Neuparth, Nuno
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Nacional de Saúde
dc.contributor.author.fl_str_mv Cano, Manuela
Nogueira, Susana
Papoila, Ana Luísa
Aguiar, Fátima
Martins, Pedro
Marques, João
Caires, Iolanda
Martins, José
Pedro, Catarina
Paixão, Paulo
Rosado-Pinto, José
Leiria-Pinto, Paula
Aelenei, Daniel
Mendes, Ana
Teixeira, João Paulo
Proença, Carmo
Neuparth, Nuno
dc.subject.por.fl_str_mv Indoor Air Quality
Day Care Centres
Exposure Assessment
Ar e Saúde Ocupacional
topic Indoor Air Quality
Day Care Centres
Exposure Assessment
Ar e Saúde Ocupacional
description This paper describes field measurements of indoor air quality (IAQ) parameters, performed in 19 Portuguese Children Day Care Centers (CDCC) during the springtime of 2011 and aims to characterize the indoor environment. The results demonstrate an association between carbon dioxide and bacterial concentrations, which in turn are affected by the number of children present in each classroom. Indoor PM10 concentrations were higher than outdoor levels (I/O ratio>1) and was also found statistically significant association between PM10 concentrations and the type of floor covering materials. These results provide evidence that IAQ is inadequate and, as a consequence, human source contaminants such as bacteria and carbon dioxide accumulate indoors. This study suggests that it is necessary to improve ventilation in order to achieve a healthier indoor environment.
publishDate 2012
dc.date.none.fl_str_mv 2012-10-31T17:58:44Z
2012-08-01
2012-08-01T00:00:00Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.18/1107
url http://hdl.handle.net/10400.18/1107
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 978-0-9816881-9-0; 0-9816881-9-5
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Dr Zhiqiang (John) Zhai, University of Colorado at Boulder, Dr. Xiangli Li, Dalian University of Technology ans Haidong Wang, University of Colorado at Boulder
publisher.none.fl_str_mv Dr Zhiqiang (John) Zhai, University of Colorado at Boulder, Dr. Xiangli Li, Dalian University of Technology ans Haidong Wang, University of Colorado at Boulder
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833599352058150912