Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models
Main Author: | |
---|---|
Publication Date: | 2010 |
Other Authors: | |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.22/3847 |
Summary: | The problem of providing a hybrid wired/wireless communications for factory automation systems is still an open issue, notwithstanding the fact that already there are some solutions. This paper describes the role of simulation tools on the validation and performance analysis of two wireless extensions for the PROFIBUS protocol. In one of them, the Intermediate Systems, which connect wired and wireless network segments, operate as repeaters. In the other one the Intermediate Systems operate as bridge. We also describe how the analytical analysis proposed for these kinds of networks can be used for the setting of some network parameters and for the guaranteeing real-time behaviour of the system. Additionally, we also compare the bridge-based solution simulation results with the analytical results. |
id |
RCAP_86c95ae55f504047cf458a8a0ee76009 |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/3847 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation modelsFieldbusWireless communicationsReal-timeIndustrial automationThe problem of providing a hybrid wired/wireless communications for factory automation systems is still an open issue, notwithstanding the fact that already there are some solutions. This paper describes the role of simulation tools on the validation and performance analysis of two wireless extensions for the PROFIBUS protocol. In one of them, the Intermediate Systems, which connect wired and wireless network segments, operate as repeaters. In the other one the Intermediate Systems operate as bridge. We also describe how the analytical analysis proposed for these kinds of networks can be used for the setting of some network parameters and for the guaranteeing real-time behaviour of the system. Additionally, we also compare the bridge-based solution simulation results with the analytical results.SpringerOpenREPOSITÓRIO P.PORTOSousa, Paulo BaltarejoFerreira, Luís Lino2014-02-12T11:03:04Z20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/3847eng1687-147210.1155/2010/845792info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-02T03:13:35Zoai:recipp.ipp.pt:10400.22/3847Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:47:21.603843Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
title |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
spellingShingle |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models Sousa, Paulo Baltarejo Fieldbus Wireless communications Real-time Industrial automation |
title_short |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
title_full |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
title_fullStr |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
title_full_unstemmed |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
title_sort |
Hybrid wired/wireless PROFIBUS architectures: performance study based on simulation models |
author |
Sousa, Paulo Baltarejo |
author_facet |
Sousa, Paulo Baltarejo Ferreira, Luís Lino |
author_role |
author |
author2 |
Ferreira, Luís Lino |
author2_role |
author |
dc.contributor.none.fl_str_mv |
REPOSITÓRIO P.PORTO |
dc.contributor.author.fl_str_mv |
Sousa, Paulo Baltarejo Ferreira, Luís Lino |
dc.subject.por.fl_str_mv |
Fieldbus Wireless communications Real-time Industrial automation |
topic |
Fieldbus Wireless communications Real-time Industrial automation |
description |
The problem of providing a hybrid wired/wireless communications for factory automation systems is still an open issue, notwithstanding the fact that already there are some solutions. This paper describes the role of simulation tools on the validation and performance analysis of two wireless extensions for the PROFIBUS protocol. In one of them, the Intermediate Systems, which connect wired and wireless network segments, operate as repeaters. In the other one the Intermediate Systems operate as bridge. We also describe how the analytical analysis proposed for these kinds of networks can be used for the setting of some network parameters and for the guaranteeing real-time behaviour of the system. Additionally, we also compare the bridge-based solution simulation results with the analytical results. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010 2010-01-01T00:00:00Z 2014-02-12T11:03:04Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/3847 |
url |
http://hdl.handle.net/10400.22/3847 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1687-1472 10.1155/2010/845792 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
SpringerOpen |
publisher.none.fl_str_mv |
SpringerOpen |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833600696358797312 |