Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position

Bibliographic Details
Main Author: Duarte, João P.
Publication Date: 2018
Other Authors: Valente-dos-Santos, João, Coelho-e-Silva, Manuel J., Couto, Pedro, Costa, Daniela, Martinho, Diogo V., Seabra, André, Cyrino, Edilson S., Conde, Jorge, Rosado, Joana, Gonçalves, Rui S.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10316/107983
https://doi.org/10.1371/journal.pone.0202261
Summary: The current study aimed to examine the reliability of the conventional and functional ratios derived from peak torques (PTs) and those obtained from the combination of knee flexors torque at the angle of knee extensors PT. Twenty-six male athletes (mean of 24.0±0.7 years) from different sports completed a test-to-test variation in isokinetic strength (Biodex, System 3) within a period of one week. Anthropometry and body composition assessed by Dual Energy X-ray Absorptiometry were also measured. The proposed isokinetic strength ratio measurements appeared to be highly reliable: conventional ratio at PT angle (intra-class correlation, ICC = 0.98; 95% confidence interval; 95%CI: 0.95 to 0.99); functional extension ratio at PT angle (ICC = 0.98; 95%CI: 0.96 to 0.99); and, functional flexion ratio at PT angle (ICC = 0.95; 95%CI: 0.89 to 0.98). Technical error of measurement (TEM) and associated percentage of the coefficient of variation (%CV) were as follows: conventional ratio at PT angle (TEM = 0.02; %CV = 4.1); functional extension ratio at PT angle (TEM = 0.02; %CV = 3.8); and, functional flexion ratio at PT angle (TEM = 0.03; %CV = 3.6). The current study demonstrated that the traditional and new obtained simple and combined isokinetic indicators seem highly reliable to assess muscle strength and function in adult male athletes. A single testing session seems to be sufficiently to obtain these isokinetic strength indicators.
id RCAP_85428e03a61b6157b35a5d6049e621af
oai_identifier_str oai:estudogeral.uc.pt:10316/107983
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle positionAthletesHumansKneeMaleMuscle Strength DynamometerReproducibility of ResultsTorqueYoung AdultMuscle StrengthMuscle, SkeletalThe current study aimed to examine the reliability of the conventional and functional ratios derived from peak torques (PTs) and those obtained from the combination of knee flexors torque at the angle of knee extensors PT. Twenty-six male athletes (mean of 24.0±0.7 years) from different sports completed a test-to-test variation in isokinetic strength (Biodex, System 3) within a period of one week. Anthropometry and body composition assessed by Dual Energy X-ray Absorptiometry were also measured. The proposed isokinetic strength ratio measurements appeared to be highly reliable: conventional ratio at PT angle (intra-class correlation, ICC = 0.98; 95% confidence interval; 95%CI: 0.95 to 0.99); functional extension ratio at PT angle (ICC = 0.98; 95%CI: 0.96 to 0.99); and, functional flexion ratio at PT angle (ICC = 0.95; 95%CI: 0.89 to 0.98). Technical error of measurement (TEM) and associated percentage of the coefficient of variation (%CV) were as follows: conventional ratio at PT angle (TEM = 0.02; %CV = 4.1); functional extension ratio at PT angle (TEM = 0.02; %CV = 3.8); and, functional flexion ratio at PT angle (TEM = 0.03; %CV = 3.6). The current study demonstrated that the traditional and new obtained simple and combined isokinetic indicators seem highly reliable to assess muscle strength and function in adult male athletes. A single testing session seems to be sufficiently to obtain these isokinetic strength indicators.Public Library of Science2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://hdl.handle.net/10316/107983https://hdl.handle.net/10316/107983https://doi.org/10.1371/journal.pone.0202261eng1932-6203Duarte, João P.Valente-dos-Santos, JoãoCoelho-e-Silva, Manuel J.Couto, PedroCosta, DanielaMartinho, Diogo V.Seabra, AndréCyrino, Edilson S.Conde, JorgeRosado, JoanaGonçalves, Rui S.info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2023-08-03T10:28:09Zoai:estudogeral.uc.pt:10316/107983Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:58:59.763945Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
title Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
spellingShingle Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
Duarte, João P.
Athletes
Humans
Knee
Male
Muscle Strength Dynamometer
Reproducibility of Results
Torque
Young Adult
Muscle Strength
Muscle, Skeletal
title_short Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
title_full Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
title_fullStr Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
title_full_unstemmed Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
title_sort Reproducibility of isokinetic strength assessment of knee muscle actions in adult athletes: Torques and antagonist-agonist ratios derived at the same angle position
author Duarte, João P.
author_facet Duarte, João P.
Valente-dos-Santos, João
Coelho-e-Silva, Manuel J.
Couto, Pedro
Costa, Daniela
Martinho, Diogo V.
Seabra, André
Cyrino, Edilson S.
Conde, Jorge
Rosado, Joana
Gonçalves, Rui S.
author_role author
author2 Valente-dos-Santos, João
Coelho-e-Silva, Manuel J.
Couto, Pedro
Costa, Daniela
Martinho, Diogo V.
Seabra, André
Cyrino, Edilson S.
Conde, Jorge
Rosado, Joana
Gonçalves, Rui S.
author2_role author
author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Duarte, João P.
Valente-dos-Santos, João
Coelho-e-Silva, Manuel J.
Couto, Pedro
Costa, Daniela
Martinho, Diogo V.
Seabra, André
Cyrino, Edilson S.
Conde, Jorge
Rosado, Joana
Gonçalves, Rui S.
dc.subject.por.fl_str_mv Athletes
Humans
Knee
Male
Muscle Strength Dynamometer
Reproducibility of Results
Torque
Young Adult
Muscle Strength
Muscle, Skeletal
topic Athletes
Humans
Knee
Male
Muscle Strength Dynamometer
Reproducibility of Results
Torque
Young Adult
Muscle Strength
Muscle, Skeletal
description The current study aimed to examine the reliability of the conventional and functional ratios derived from peak torques (PTs) and those obtained from the combination of knee flexors torque at the angle of knee extensors PT. Twenty-six male athletes (mean of 24.0±0.7 years) from different sports completed a test-to-test variation in isokinetic strength (Biodex, System 3) within a period of one week. Anthropometry and body composition assessed by Dual Energy X-ray Absorptiometry were also measured. The proposed isokinetic strength ratio measurements appeared to be highly reliable: conventional ratio at PT angle (intra-class correlation, ICC = 0.98; 95% confidence interval; 95%CI: 0.95 to 0.99); functional extension ratio at PT angle (ICC = 0.98; 95%CI: 0.96 to 0.99); and, functional flexion ratio at PT angle (ICC = 0.95; 95%CI: 0.89 to 0.98). Technical error of measurement (TEM) and associated percentage of the coefficient of variation (%CV) were as follows: conventional ratio at PT angle (TEM = 0.02; %CV = 4.1); functional extension ratio at PT angle (TEM = 0.02; %CV = 3.8); and, functional flexion ratio at PT angle (TEM = 0.03; %CV = 3.6). The current study demonstrated that the traditional and new obtained simple and combined isokinetic indicators seem highly reliable to assess muscle strength and function in adult male athletes. A single testing session seems to be sufficiently to obtain these isokinetic strength indicators.
publishDate 2018
dc.date.none.fl_str_mv 2018
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/107983
https://hdl.handle.net/10316/107983
https://doi.org/10.1371/journal.pone.0202261
url https://hdl.handle.net/10316/107983
https://doi.org/10.1371/journal.pone.0202261
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1932-6203
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Public Library of Science
publisher.none.fl_str_mv Public Library of Science
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602538757160960