Export Ready — 

Visual acuity in high astigmatic eyes in Salta, Argentina

Bibliographic Details
Main Author: Danza, Rubén D.
Publication Date: 2024
Other Authors: Szeps, Abel, Iribarren, Rafael, Lança, Carla
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.21/17901
Summary: Purpose: To identify factors that affect uncorrected visual acuity (UCVA) in highly astigmatic eyes. Methods: This clinical study was performed at an Ophthalmology Clinic in the Northwest region of Argentina. The study population consisted of all consecutive patients, aged between 10 and 40 years, with bilateral astigmatism higher than 2 dioptres (D) in at least one eye. The protocol included the following tests: UCVA, pinhole VA, best-corrected VA (BCVA), keratometry, scotopic pupil diameter measurement, subjective refraction, and objective refraction with cycloplegia. Results: A total of 405 patients were included in the study. Their mean age was 22.04 ± 10.62 years and 52.3% were female (n=212). The mean SE was -1.53 ± 1.79 D and the mean scotopic pupil was 5.4 ± 0.3 mm. In multiple linear logistic regression analysis, excluding amblyopes, worse pinhole VA (Odds ratio [OR]: 8.19, 95% confidence intervals [CI]: 4.76 to 14.07; p<0,001) and higher scotopic pupil size were significantly associated with worse UCVA. The presence of amblyopia was associated with higher pupillary diameter (OR: 4.37; 95% CI: 1.60 to 11.97; p=0.004). Conclusions: Our study revealed that pupil size affects UCVA in the astigmatic eyes of subjects living in a rural environment. Thus, further studies are necessary to understand if the correction of astigmatism should take in consideration pupil size, pinhole VA, and UCVA.
id RCAP_8393fefd3dc2a263e442539e71a64a23
oai_identifier_str oai:repositorio.ipl.pt:10400.21/17901
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Visual acuity in high astigmatic eyes in Salta, ArgentinaAgudeza visual en ojos con alto astigmatismo en Salta, ArgentinaOphthalmologyHigh astigmatismRefractionPupil sizeEpidemiologyOftalmologíaAstigmatismo altoRefracciónTamaño pupilaEpidemiologíaPurpose: To identify factors that affect uncorrected visual acuity (UCVA) in highly astigmatic eyes. Methods: This clinical study was performed at an Ophthalmology Clinic in the Northwest region of Argentina. The study population consisted of all consecutive patients, aged between 10 and 40 years, with bilateral astigmatism higher than 2 dioptres (D) in at least one eye. The protocol included the following tests: UCVA, pinhole VA, best-corrected VA (BCVA), keratometry, scotopic pupil diameter measurement, subjective refraction, and objective refraction with cycloplegia. Results: A total of 405 patients were included in the study. Their mean age was 22.04 ± 10.62 years and 52.3% were female (n=212). The mean SE was -1.53 ± 1.79 D and the mean scotopic pupil was 5.4 ± 0.3 mm. In multiple linear logistic regression analysis, excluding amblyopes, worse pinhole VA (Odds ratio [OR]: 8.19, 95% confidence intervals [CI]: 4.76 to 14.07; p<0,001) and higher scotopic pupil size were significantly associated with worse UCVA. The presence of amblyopia was associated with higher pupillary diameter (OR: 4.37; 95% CI: 1.60 to 11.97; p=0.004). Conclusions: Our study revealed that pupil size affects UCVA in the astigmatic eyes of subjects living in a rural environment. Thus, further studies are necessary to understand if the correction of astigmatism should take in consideration pupil size, pinhole VA, and UCVA.Consejo Argentino de OftalmologíaRCIPLDanza, Rubén D.Szeps, AbelIribarren, RafaelLança, Carla2024-11-13T17:39:15Z2024-092024-09-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/17901eng10.70313/2718.7446.v17.n03.346info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-12T08:18:35Zoai:repositorio.ipl.pt:10400.21/17901Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T19:54:47.487949Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Visual acuity in high astigmatic eyes in Salta, Argentina
Agudeza visual en ojos con alto astigmatismo en Salta, Argentina
title Visual acuity in high astigmatic eyes in Salta, Argentina
spellingShingle Visual acuity in high astigmatic eyes in Salta, Argentina
Danza, Rubén D.
Ophthalmology
High astigmatism
Refraction
Pupil size
Epidemiology
Oftalmología
Astigmatismo alto
Refracción
Tamaño pupila
Epidemiología
title_short Visual acuity in high astigmatic eyes in Salta, Argentina
title_full Visual acuity in high astigmatic eyes in Salta, Argentina
title_fullStr Visual acuity in high astigmatic eyes in Salta, Argentina
title_full_unstemmed Visual acuity in high astigmatic eyes in Salta, Argentina
title_sort Visual acuity in high astigmatic eyes in Salta, Argentina
author Danza, Rubén D.
author_facet Danza, Rubén D.
Szeps, Abel
Iribarren, Rafael
Lança, Carla
author_role author
author2 Szeps, Abel
Iribarren, Rafael
Lança, Carla
author2_role author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Danza, Rubén D.
Szeps, Abel
Iribarren, Rafael
Lança, Carla
dc.subject.por.fl_str_mv Ophthalmology
High astigmatism
Refraction
Pupil size
Epidemiology
Oftalmología
Astigmatismo alto
Refracción
Tamaño pupila
Epidemiología
topic Ophthalmology
High astigmatism
Refraction
Pupil size
Epidemiology
Oftalmología
Astigmatismo alto
Refracción
Tamaño pupila
Epidemiología
description Purpose: To identify factors that affect uncorrected visual acuity (UCVA) in highly astigmatic eyes. Methods: This clinical study was performed at an Ophthalmology Clinic in the Northwest region of Argentina. The study population consisted of all consecutive patients, aged between 10 and 40 years, with bilateral astigmatism higher than 2 dioptres (D) in at least one eye. The protocol included the following tests: UCVA, pinhole VA, best-corrected VA (BCVA), keratometry, scotopic pupil diameter measurement, subjective refraction, and objective refraction with cycloplegia. Results: A total of 405 patients were included in the study. Their mean age was 22.04 ± 10.62 years and 52.3% were female (n=212). The mean SE was -1.53 ± 1.79 D and the mean scotopic pupil was 5.4 ± 0.3 mm. In multiple linear logistic regression analysis, excluding amblyopes, worse pinhole VA (Odds ratio [OR]: 8.19, 95% confidence intervals [CI]: 4.76 to 14.07; p<0,001) and higher scotopic pupil size were significantly associated with worse UCVA. The presence of amblyopia was associated with higher pupillary diameter (OR: 4.37; 95% CI: 1.60 to 11.97; p=0.004). Conclusions: Our study revealed that pupil size affects UCVA in the astigmatic eyes of subjects living in a rural environment. Thus, further studies are necessary to understand if the correction of astigmatism should take in consideration pupil size, pinhole VA, and UCVA.
publishDate 2024
dc.date.none.fl_str_mv 2024-11-13T17:39:15Z
2024-09
2024-09-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/17901
url http://hdl.handle.net/10400.21/17901
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.70313/2718.7446.v17.n03.346
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Consejo Argentino de Oftalmología
publisher.none.fl_str_mv Consejo Argentino de Oftalmología
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833598394301415424