Surface characterization of a new ceramic dental implant
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , , |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.14/33912 |
Summary: | This research compares the polished and rough surface of three commercially available dental implants, made of zirconia, titanium grade IV and titanium zirconium. The analysis was done on a Confocal Profilometer at 50x. Results from this analysis show a similar average roughness over the polished surface (Sa value) of the titanium (0,1290 mu m), titanium zirconium (0,1642 mu m) and zirconia implant (0,1523 mu m). However, the results of the analysis of the rough surface show a lower average roughness of the zirconia implant (1,5835 mu m) compared to titanium (3,5986 mu m) and titanium zirconium implant (3,0878 mu m). |
id |
RCAP_792ccfba24a6e5aa96f91ab7d78462d2 |
---|---|
oai_identifier_str |
oai:repositorio.ucp.pt:10400.14/33912 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Surface characterization of a new ceramic dental implantDental implantZirconiaTitaniumSurface characterizationRoughnessThis research compares the polished and rough surface of three commercially available dental implants, made of zirconia, titanium grade IV and titanium zirconium. The analysis was done on a Confocal Profilometer at 50x. Results from this analysis show a similar average roughness over the polished surface (Sa value) of the titanium (0,1290 mu m), titanium zirconium (0,1642 mu m) and zirconia implant (0,1523 mu m). However, the results of the analysis of the rough surface show a lower average roughness of the zirconia implant (1,5835 mu m) compared to titanium (3,5986 mu m) and titanium zirconium implant (3,0878 mu m).Universidade do PortoVeritatiMiranda, MónicaMarques, TiagoCorreia, AndréLobo, FábioFernandes, HelenaMiranda, CéliaAraújo, Filipe2021-06-24T10:36:25Z2015-072015-07-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.14/33912eng97898998832229789899883239info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-13T16:09:07Zoai:repositorio.ucp.pt:10400.14/33912Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T02:18:31.510790Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Surface characterization of a new ceramic dental implant |
title |
Surface characterization of a new ceramic dental implant |
spellingShingle |
Surface characterization of a new ceramic dental implant Miranda, Mónica Dental implant Zirconia Titanium Surface characterization Roughness |
title_short |
Surface characterization of a new ceramic dental implant |
title_full |
Surface characterization of a new ceramic dental implant |
title_fullStr |
Surface characterization of a new ceramic dental implant |
title_full_unstemmed |
Surface characterization of a new ceramic dental implant |
title_sort |
Surface characterization of a new ceramic dental implant |
author |
Miranda, Mónica |
author_facet |
Miranda, Mónica Marques, Tiago Correia, André Lobo, Fábio Fernandes, Helena Miranda, Célia Araújo, Filipe |
author_role |
author |
author2 |
Marques, Tiago Correia, André Lobo, Fábio Fernandes, Helena Miranda, Célia Araújo, Filipe |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Veritati |
dc.contributor.author.fl_str_mv |
Miranda, Mónica Marques, Tiago Correia, André Lobo, Fábio Fernandes, Helena Miranda, Célia Araújo, Filipe |
dc.subject.por.fl_str_mv |
Dental implant Zirconia Titanium Surface characterization Roughness |
topic |
Dental implant Zirconia Titanium Surface characterization Roughness |
description |
This research compares the polished and rough surface of three commercially available dental implants, made of zirconia, titanium grade IV and titanium zirconium. The analysis was done on a Confocal Profilometer at 50x. Results from this analysis show a similar average roughness over the polished surface (Sa value) of the titanium (0,1290 mu m), titanium zirconium (0,1642 mu m) and zirconia implant (0,1523 mu m). However, the results of the analysis of the rough surface show a lower average roughness of the zirconia implant (1,5835 mu m) compared to titanium (3,5986 mu m) and titanium zirconium implant (3,0878 mu m). |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-07 2015-07-01T00:00:00Z 2021-06-24T10:36:25Z |
dc.type.driver.fl_str_mv |
conference object |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.14/33912 |
url |
http://hdl.handle.net/10400.14/33912 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
9789899883222 9789899883239 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade do Porto |
publisher.none.fl_str_mv |
Universidade do Porto |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833601305254297600 |