Export Ready — 

Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images

Bibliographic Details
Main Author: Elias, Maria
Publication Date: 2019
Other Authors: Jorge, Pedro, Figueiredo, Sérgio, Oliveira, Luís, Pereira, Edgar L.
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.21/11634
Summary: The aim of this work was to implement an automatic application (AA) for the quantification of the striatum transaxial slices based on [I-123]FP-CIT SPECT (Single Photon Emission Tomography) images. A sample of 68 subjects with and without pathology was collected from the nuclear medicine department of the Hospital Particular de Almada. In order to compare the striatum specific uptake ratios (SUR), a semi-automatic application (SAA) was also developed allowing manual adjustments by a specialist operator. The obtained results were compared with the DaTSCAN (R) V4 application, from General Electric Healthcare. The experimental results based on SUR demonstrate that the AA can successfully discriminate the healthy patients from the pathological subjects. Additionally, a strong correlation was verified between the AA and the semi-automatic methods (DaTSCAN (R) V4 and the SAA). These methods also evidence intra and inter-operator variability, suppressed by the AA. The proposed methodology for segmentation and quantification of the striatum transaxial images obtained by [I-123]FP-CIT SPECT demonstrated that the developed application can accurately complement the visual analysis, requiring future optimization.
id RCAP_6fe9df04f5a6b2abb4960aebb33610c6
oai_identifier_str oai:repositorio.ipl.pt:10400.21/11634
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT imagesSingle photon emission computed tomographyAutomatic applicationSpecific uptake ratioStriatum transaxial imagesDaTSCAN V4 applicationThe aim of this work was to implement an automatic application (AA) for the quantification of the striatum transaxial slices based on [I-123]FP-CIT SPECT (Single Photon Emission Tomography) images. A sample of 68 subjects with and without pathology was collected from the nuclear medicine department of the Hospital Particular de Almada. In order to compare the striatum specific uptake ratios (SUR), a semi-automatic application (SAA) was also developed allowing manual adjustments by a specialist operator. The obtained results were compared with the DaTSCAN (R) V4 application, from General Electric Healthcare. The experimental results based on SUR demonstrate that the AA can successfully discriminate the healthy patients from the pathological subjects. Additionally, a strong correlation was verified between the AA and the semi-automatic methods (DaTSCAN (R) V4 and the SAA). These methods also evidence intra and inter-operator variability, suppressed by the AA. The proposed methodology for segmentation and quantification of the striatum transaxial images obtained by [I-123]FP-CIT SPECT demonstrated that the developed application can accurately complement the visual analysis, requiring future optimization.Institute of Electrical and Electronics EngineersRCIPLElias, MariaJorge, PedroFigueiredo, SérgioOliveira, LuísPereira, Edgar L.2020-05-12T16:58:29Z2019-04-182019-04-18T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.21/11634eng978-1-5386-8507-5978-1-5386-8506-810.1109/ENBENG.2019.8692477info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-12T07:33:13Zoai:repositorio.ipl.pt:10400.21/11634Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T19:50:25.089671Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
title Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
spellingShingle Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
Elias, Maria
Single photon emission computed tomography
Automatic application
Specific uptake ratio
Striatum transaxial images
DaTSCAN V4 application
title_short Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
title_full Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
title_fullStr Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
title_full_unstemmed Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
title_sort Automatic versus semi-automatic method for the striatum specific uptake ratio quantification based on [I-123]FP-CIT SPECT images
author Elias, Maria
author_facet Elias, Maria
Jorge, Pedro
Figueiredo, Sérgio
Oliveira, Luís
Pereira, Edgar L.
author_role author
author2 Jorge, Pedro
Figueiredo, Sérgio
Oliveira, Luís
Pereira, Edgar L.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv RCIPL
dc.contributor.author.fl_str_mv Elias, Maria
Jorge, Pedro
Figueiredo, Sérgio
Oliveira, Luís
Pereira, Edgar L.
dc.subject.por.fl_str_mv Single photon emission computed tomography
Automatic application
Specific uptake ratio
Striatum transaxial images
DaTSCAN V4 application
topic Single photon emission computed tomography
Automatic application
Specific uptake ratio
Striatum transaxial images
DaTSCAN V4 application
description The aim of this work was to implement an automatic application (AA) for the quantification of the striatum transaxial slices based on [I-123]FP-CIT SPECT (Single Photon Emission Tomography) images. A sample of 68 subjects with and without pathology was collected from the nuclear medicine department of the Hospital Particular de Almada. In order to compare the striatum specific uptake ratios (SUR), a semi-automatic application (SAA) was also developed allowing manual adjustments by a specialist operator. The obtained results were compared with the DaTSCAN (R) V4 application, from General Electric Healthcare. The experimental results based on SUR demonstrate that the AA can successfully discriminate the healthy patients from the pathological subjects. Additionally, a strong correlation was verified between the AA and the semi-automatic methods (DaTSCAN (R) V4 and the SAA). These methods also evidence intra and inter-operator variability, suppressed by the AA. The proposed methodology for segmentation and quantification of the striatum transaxial images obtained by [I-123]FP-CIT SPECT demonstrated that the developed application can accurately complement the visual analysis, requiring future optimization.
publishDate 2019
dc.date.none.fl_str_mv 2019-04-18
2019-04-18T00:00:00Z
2020-05-12T16:58:29Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/11634
url http://hdl.handle.net/10400.21/11634
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 978-1-5386-8507-5
978-1-5386-8506-8
10.1109/ENBENG.2019.8692477
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers
publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833598351339159552