Speech articulation assessment using dynamic magnetic resonance imaging techniques

Bibliographic Details
Main Author: S. R. Ventura
Publication Date: 2011
Other Authors: M. J. M. Vasconcelos, D. R. Freitas, I. M. Ramos, João Manuel R. S.Tavares
Format: Book
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10216/56790
Summary: Magnetic Resonance Imaging (MRI) has been successfully applied on real-time analysis of the articulators during speech production along the whole vocal tract, with good signal-to-noise ratio and without ionizing effects. Because speech dynamic events need a minimal sampling rate, an improvement on the temporal resolution of MRI systems is demanded. Our aim is to describe a dynamic MRI technique to acquire and assess the main articulatory events during the production of some European Portuguese utterances. Hence, novel perceptions for dynamic MRI technique using a 3.0 Tesla System are presented in order to study the shape of the vocal tract during speech production.
id RCAP_6e68e4b293009e908bdeb415a4ac8f04
oai_identifier_str oai:repositorio-aberto.up.pt:10216/56790
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Speech articulation assessment using dynamic magnetic resonance imaging techniquesProcessamento de imagem, Engenharia mecânicaImage processing, Mechanical engineeringMagnetic Resonance Imaging (MRI) has been successfully applied on real-time analysis of the articulators during speech production along the whole vocal tract, with good signal-to-noise ratio and without ionizing effects. Because speech dynamic events need a minimal sampling rate, an improvement on the temporal resolution of MRI systems is demanded. Our aim is to describe a dynamic MRI technique to acquire and assess the main articulatory events during the production of some European Portuguese utterances. Hence, novel perceptions for dynamic MRI technique using a 3.0 Tesla System are presented in order to study the shape of the vocal tract during speech production.20112011-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/56790engS. R. VenturaM. J. M. VasconcelosD. R. FreitasI. M. RamosJoão Manuel R. S.Tavaresinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:58:06Zoai:repositorio-aberto.up.pt:10216/56790Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:41:35.736945Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Speech articulation assessment using dynamic magnetic resonance imaging techniques
title Speech articulation assessment using dynamic magnetic resonance imaging techniques
spellingShingle Speech articulation assessment using dynamic magnetic resonance imaging techniques
S. R. Ventura
Processamento de imagem, Engenharia mecânica
Image processing, Mechanical engineering
title_short Speech articulation assessment using dynamic magnetic resonance imaging techniques
title_full Speech articulation assessment using dynamic magnetic resonance imaging techniques
title_fullStr Speech articulation assessment using dynamic magnetic resonance imaging techniques
title_full_unstemmed Speech articulation assessment using dynamic magnetic resonance imaging techniques
title_sort Speech articulation assessment using dynamic magnetic resonance imaging techniques
author S. R. Ventura
author_facet S. R. Ventura
M. J. M. Vasconcelos
D. R. Freitas
I. M. Ramos
João Manuel R. S.Tavares
author_role author
author2 M. J. M. Vasconcelos
D. R. Freitas
I. M. Ramos
João Manuel R. S.Tavares
author2_role author
author
author
author
dc.contributor.author.fl_str_mv S. R. Ventura
M. J. M. Vasconcelos
D. R. Freitas
I. M. Ramos
João Manuel R. S.Tavares
dc.subject.por.fl_str_mv Processamento de imagem, Engenharia mecânica
Image processing, Mechanical engineering
topic Processamento de imagem, Engenharia mecânica
Image processing, Mechanical engineering
description Magnetic Resonance Imaging (MRI) has been successfully applied on real-time analysis of the articulators during speech production along the whole vocal tract, with good signal-to-noise ratio and without ionizing effects. Because speech dynamic events need a minimal sampling rate, an improvement on the temporal resolution of MRI systems is demanded. Our aim is to describe a dynamic MRI technique to acquire and assess the main articulatory events during the production of some European Portuguese utterances. Hence, novel perceptions for dynamic MRI technique using a 3.0 Tesla System are presented in order to study the shape of the vocal tract during speech production.
publishDate 2011
dc.date.none.fl_str_mv 2011
2011-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/book
format book
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/56790
url https://hdl.handle.net/10216/56790
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600254005477376