Measurements in 1149.4 environments - correcting the infrastructure switches influence
Main Author: | |
---|---|
Publication Date: | 2007 |
Other Authors: | , |
Format: | Book |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/10216/84671 |
Summary: | Measuring the values of discrete components frequently takes place during the test or debug phase of Printed Circuit Boards (PCB). This operation requires tools that are based on some access type. The shrinking geometries constrain the straightforward use of tools based on physical access. One of the aims of the IEEE1149.4 Std. is to facilitate those on-board measurements. This infrastructure relies on electronic access that includes high quality analog buses and a set of electronic switches, which enable to completely isolate a component under characterization, e.g. by injecting a known current and measuring the voltage across it. During this process, the infrastructure switches have a negative impact in the measurement accuracy. This paper analyses the measurement of one resistor in two situations: connected between a pin and ground and between two pins. The infrastructure switches that affect the measurement quality are identified and the upper limit of its systematic error is characterized. When the systematic error is completely defined then it is possible to remove its negative effect from the final result. |
id |
RCAP_6d7d6e9e5dc886b9810f6e902a8ff704 |
---|---|
oai_identifier_str |
oai:repositorio-aberto.up.pt:10216/84671 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Measurements in 1149.4 environments - correcting the infrastructure switches influenceEngenharia electrotécnica, electrónica e informáticaElectrical engineering, Electronic engineering, Information engineeringMeasuring the values of discrete components frequently takes place during the test or debug phase of Printed Circuit Boards (PCB). This operation requires tools that are based on some access type. The shrinking geometries constrain the straightforward use of tools based on physical access. One of the aims of the IEEE1149.4 Std. is to facilitate those on-board measurements. This infrastructure relies on electronic access that includes high quality analog buses and a set of electronic switches, which enable to completely isolate a component under characterization, e.g. by injecting a known current and measuring the voltage across it. During this process, the infrastructure switches have a negative impact in the measurement accuracy. This paper analyses the measurement of one resistor in two situations: connected between a pin and ground and between two pins. The infrastructure switches that affect the measurement quality are identified and the upper limit of its systematic error is characterized. When the systematic error is completely defined then it is possible to remove its negative effect from the final result.20072007-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/84671engManuel C. FelgueirasGustavo R. AlvesJosé M. M. Ferreirainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:07:55Zoai:repositorio-aberto.up.pt:10216/84671Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:08:38.271035Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
title |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
spellingShingle |
Measurements in 1149.4 environments - correcting the infrastructure switches influence Manuel C. Felgueiras Engenharia electrotécnica, electrónica e informática Electrical engineering, Electronic engineering, Information engineering |
title_short |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
title_full |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
title_fullStr |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
title_full_unstemmed |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
title_sort |
Measurements in 1149.4 environments - correcting the infrastructure switches influence |
author |
Manuel C. Felgueiras |
author_facet |
Manuel C. Felgueiras Gustavo R. Alves José M. M. Ferreira |
author_role |
author |
author2 |
Gustavo R. Alves José M. M. Ferreira |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Manuel C. Felgueiras Gustavo R. Alves José M. M. Ferreira |
dc.subject.por.fl_str_mv |
Engenharia electrotécnica, electrónica e informática Electrical engineering, Electronic engineering, Information engineering |
topic |
Engenharia electrotécnica, electrónica e informática Electrical engineering, Electronic engineering, Information engineering |
description |
Measuring the values of discrete components frequently takes place during the test or debug phase of Printed Circuit Boards (PCB). This operation requires tools that are based on some access type. The shrinking geometries constrain the straightforward use of tools based on physical access. One of the aims of the IEEE1149.4 Std. is to facilitate those on-board measurements. This infrastructure relies on electronic access that includes high quality analog buses and a set of electronic switches, which enable to completely isolate a component under characterization, e.g. by injecting a known current and measuring the voltage across it. During this process, the infrastructure switches have a negative impact in the measurement accuracy. This paper analyses the measurement of one resistor in two situations: connected between a pin and ground and between two pins. The infrastructure switches that affect the measurement quality are identified and the upper limit of its systematic error is characterized. When the systematic error is completely defined then it is possible to remove its negative effect from the final result. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 2007-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/book |
format |
book |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10216/84671 |
url |
https://hdl.handle.net/10216/84671 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833600028329902080 |