Proposal of a CLT reinforcement of old timber floors
Main Author: | |
---|---|
Publication Date: | 2019 |
Other Authors: | , , |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/1822/66269 |
Summary: | Despite the fact that, from the mechanical point of view, there is no ageing issues of timber elements when they are properly used, many old timber structures require important interventions because of changes in uses (which modifies the regulating rules for example), of material decay (misuse of timber) or possibly of a faulty design or construction. In particular, timber floors in old structures often present large deflections and most the time had been designed for a maximum load much lower than the one prescribed by contemporary rules. After an introduction about timber floors and a short review about the reinforcement technics that exist, the present paper presents a new proposal for their reinforcement. The solution developed in the present paper uses a Cross Laminated Timber (CLT) panel screwed over the existing floor, keeping a small gap between the panel and the existing joists. In this way, the new “composite” floor presents higher stiffness and the gap is used for horizontal line runs. For the design of such a “composite floor”, modified Johanssen’s equations (including the gap between the CLT panel and the joists) are proposed and their application on a case study is presented. |
id |
RCAP_6a9b4ad19e3e2f5196f0e5641d83ae53 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/66269 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Proposal of a CLT reinforcement of old timber floorsCLTRefurbishmentSelf-tapping screwsTimber floorsDespite the fact that, from the mechanical point of view, there is no ageing issues of timber elements when they are properly used, many old timber structures require important interventions because of changes in uses (which modifies the regulating rules for example), of material decay (misuse of timber) or possibly of a faulty design or construction. In particular, timber floors in old structures often present large deflections and most the time had been designed for a maximum load much lower than the one prescribed by contemporary rules. After an introduction about timber floors and a short review about the reinforcement technics that exist, the present paper presents a new proposal for their reinforcement. The solution developed in the present paper uses a Cross Laminated Timber (CLT) panel screwed over the existing floor, keeping a small gap between the panel and the existing joists. In this way, the new “composite” floor presents higher stiffness and the gap is used for horizontal line runs. For the design of such a “composite floor”, modified Johanssen’s equations (including the gap between the CLT panel and the joists) are proposed and their application on a case study is presented.- (undefined)SpringerUniversidade do MinhoRoensmaens, BertrandVan Parys, LaurentBranco, Jorge M.Descamps, Thierry20192019-01-01T00:00:00Zbook partinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/66269eng2211-084410.1007/978-3-319-99441-3_169info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T06:09:26Zoai:repositorium.sdum.uminho.pt:1822/66269Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:43:01.441323Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Proposal of a CLT reinforcement of old timber floors |
title |
Proposal of a CLT reinforcement of old timber floors |
spellingShingle |
Proposal of a CLT reinforcement of old timber floors Roensmaens, Bertrand CLT Refurbishment Self-tapping screws Timber floors |
title_short |
Proposal of a CLT reinforcement of old timber floors |
title_full |
Proposal of a CLT reinforcement of old timber floors |
title_fullStr |
Proposal of a CLT reinforcement of old timber floors |
title_full_unstemmed |
Proposal of a CLT reinforcement of old timber floors |
title_sort |
Proposal of a CLT reinforcement of old timber floors |
author |
Roensmaens, Bertrand |
author_facet |
Roensmaens, Bertrand Van Parys, Laurent Branco, Jorge M. Descamps, Thierry |
author_role |
author |
author2 |
Van Parys, Laurent Branco, Jorge M. Descamps, Thierry |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Roensmaens, Bertrand Van Parys, Laurent Branco, Jorge M. Descamps, Thierry |
dc.subject.por.fl_str_mv |
CLT Refurbishment Self-tapping screws Timber floors |
topic |
CLT Refurbishment Self-tapping screws Timber floors |
description |
Despite the fact that, from the mechanical point of view, there is no ageing issues of timber elements when they are properly used, many old timber structures require important interventions because of changes in uses (which modifies the regulating rules for example), of material decay (misuse of timber) or possibly of a faulty design or construction. In particular, timber floors in old structures often present large deflections and most the time had been designed for a maximum load much lower than the one prescribed by contemporary rules. After an introduction about timber floors and a short review about the reinforcement technics that exist, the present paper presents a new proposal for their reinforcement. The solution developed in the present paper uses a Cross Laminated Timber (CLT) panel screwed over the existing floor, keeping a small gap between the panel and the existing joists. In this way, the new “composite” floor presents higher stiffness and the gap is used for horizontal line runs. For the design of such a “composite floor”, modified Johanssen’s equations (including the gap between the CLT panel and the joists) are proposed and their application on a case study is presented. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2019-01-01T00:00:00Z |
dc.type.driver.fl_str_mv |
book part |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/66269 |
url |
http://hdl.handle.net/1822/66269 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2211-0844 10.1007/978-3-319-99441-3_169 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Springer |
publisher.none.fl_str_mv |
Springer |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833595493747261440 |