Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation
Main Author: | |
---|---|
Publication Date: | 2011 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.26/18221 |
Summary: | In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics' in order to optimise radiological practice. ESD values were obtained using an ionisation chamber Diamentor M4 KDK (PTW) in 429 children, who underwent chest X-ray or pelvis X-ray in a Computed Radiography system. In the first phase of the study, data were collected according to protocols used in the department; in a second phase different tube voltage values were used according to patient weight. A third phase was carried out, only for chest X-ray, using the exposure parameters of phase 2, plus activating lateral ionisation chamber. Three paediatric radiologists blindly assessed image quality of chest X-ray, using a validated assessment available in the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics'. Considering all the patients submitted to chest X-ray, the average ESD was 0.22, 0.16 and 0.08 mGy, for phases 1, 2 and 3, respectively. For pelvis X-ray, the average ESD decreased from 1.18 mGy in phase 1 to 0.78 mGy in phase 2. Dose optimisation was achieved. ESD was reduced 63.6 and 33.9 % in chest and pelvis X-ray, respectively. |
id |
RCAP_697e3e080359b50e02d4a2ebd986e688 |
---|---|
oai_identifier_str |
oai:comum.rcaap.pt:10400.26/18221 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisationAdolescentChildPreschool ChildHumansInfantNewborn InfantPelvisPractice Guidelines as TopicRadiation DosageRadiographic Image EnhancementThoracic RadiographySkinX-Ray ComputedTomographyPediatric HospitalsX-Ray Intensifying ScreensIn paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics' in order to optimise radiological practice. ESD values were obtained using an ionisation chamber Diamentor M4 KDK (PTW) in 429 children, who underwent chest X-ray or pelvis X-ray in a Computed Radiography system. In the first phase of the study, data were collected according to protocols used in the department; in a second phase different tube voltage values were used according to patient weight. A third phase was carried out, only for chest X-ray, using the exposure parameters of phase 2, plus activating lateral ionisation chamber. Three paediatric radiologists blindly assessed image quality of chest X-ray, using a validated assessment available in the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics'. Considering all the patients submitted to chest X-ray, the average ESD was 0.22, 0.16 and 0.08 mGy, for phases 1, 2 and 3, respectively. For pelvis X-ray, the average ESD decreased from 1.18 mGy in phase 1 to 0.78 mGy in phase 2. Dose optimisation was achieved. ESD was reduced 63.6 and 33.9 % in chest and pelvis X-ray, respectively.Oxford University PressRepositório ComumPaulo, GracianoSantos, JoanaMoreira, AnaFigueiredo, Filipa2017-04-20T11:54:26Z20112011-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.26/18221eng10.1093/rpd/ncr355info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-05-02T11:24:22Zoai:comum.rcaap.pt:10400.26/18221Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T06:44:35.634627Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
title |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
spellingShingle |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation Paulo, Graciano Adolescent Child Preschool Child Humans Infant Newborn Infant Pelvis Practice Guidelines as Topic Radiation Dosage Radiographic Image Enhancement Thoracic Radiography Skin X-Ray ComputedTomography Pediatric Hospitals X-Ray Intensifying Screens |
title_short |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
title_full |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
title_fullStr |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
title_full_unstemmed |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
title_sort |
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation |
author |
Paulo, Graciano |
author_facet |
Paulo, Graciano Santos, Joana Moreira, Ana Figueiredo, Filipa |
author_role |
author |
author2 |
Santos, Joana Moreira, Ana Figueiredo, Filipa |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Repositório Comum |
dc.contributor.author.fl_str_mv |
Paulo, Graciano Santos, Joana Moreira, Ana Figueiredo, Filipa |
dc.subject.por.fl_str_mv |
Adolescent Child Preschool Child Humans Infant Newborn Infant Pelvis Practice Guidelines as Topic Radiation Dosage Radiographic Image Enhancement Thoracic Radiography Skin X-Ray ComputedTomography Pediatric Hospitals X-Ray Intensifying Screens |
topic |
Adolescent Child Preschool Child Humans Infant Newborn Infant Pelvis Practice Guidelines as Topic Radiation Dosage Radiographic Image Enhancement Thoracic Radiography Skin X-Ray ComputedTomography Pediatric Hospitals X-Ray Intensifying Screens |
description |
In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics' in order to optimise radiological practice. ESD values were obtained using an ionisation chamber Diamentor M4 KDK (PTW) in 429 children, who underwent chest X-ray or pelvis X-ray in a Computed Radiography system. In the first phase of the study, data were collected according to protocols used in the department; in a second phase different tube voltage values were used according to patient weight. A third phase was carried out, only for chest X-ray, using the exposure parameters of phase 2, plus activating lateral ionisation chamber. Three paediatric radiologists blindly assessed image quality of chest X-ray, using a validated assessment available in the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics'. Considering all the patients submitted to chest X-ray, the average ESD was 0.22, 0.16 and 0.08 mGy, for phases 1, 2 and 3, respectively. For pelvis X-ray, the average ESD decreased from 1.18 mGy in phase 1 to 0.78 mGy in phase 2. Dose optimisation was achieved. ESD was reduced 63.6 and 33.9 % in chest and pelvis X-ray, respectively. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011 2011-01-01T00:00:00Z 2017-04-20T11:54:26Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.26/18221 |
url |
http://hdl.handle.net/10400.26/18221 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1093/rpd/ncr355 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Oxford University Press |
publisher.none.fl_str_mv |
Oxford University Press |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833602771215974400 |