Interactions between contact lenses and lens care solutions: Influence in optical properties

Bibliographic Details
Main Author: Alves, Micael
Publication Date: 2021
Other Authors: Castanheira, Elisabete M. S., Lira, Madalena
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/1822/78313
Summary: Purpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior.
id RCAP_65acd59b9f06c6cfc40643612d2ab56e
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/78313
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Interactions between contact lenses and lens care solutions: Influence in optical propertiesContact lensesLens care solutionsUltraviolet radiationVisible spectraTransmittanceFluorescenceCiências Naturais::Ciências FísicasScience & TechnologyPurpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior.This work was supported by the Portuguese Foundation for Science and Technology (FCT-Portugal) in the framework of the Strategic Funding of CF-UM-UP (UIDB/04650/2020) .ElsevierUniversidade do MinhoAlves, MicaelCastanheira, Elisabete M. S.Lira, Madalena2021-092021-09-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://hdl.handle.net/1822/78313engAlves, M., Castanheira, E. M. S., & Lira, M. (2021, October). Interactions between contact lenses and lens care solutions: Influence in optical properties. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2021.01.0091367-048410.1016/j.clae.2021.01.00933579643https://linkinghub.elsevier.com/retrieve/pii/S136704842100014Xinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T05:23:59Zoai:repositorium.sdum.uminho.pt:1822/78313Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:30:28.842631Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Interactions between contact lenses and lens care solutions: Influence in optical properties
title Interactions between contact lenses and lens care solutions: Influence in optical properties
spellingShingle Interactions between contact lenses and lens care solutions: Influence in optical properties
Alves, Micael
Contact lenses
Lens care solutions
Ultraviolet radiation
Visible spectra
Transmittance
Fluorescence
Ciências Naturais::Ciências Físicas
Science & Technology
title_short Interactions between contact lenses and lens care solutions: Influence in optical properties
title_full Interactions between contact lenses and lens care solutions: Influence in optical properties
title_fullStr Interactions between contact lenses and lens care solutions: Influence in optical properties
title_full_unstemmed Interactions between contact lenses and lens care solutions: Influence in optical properties
title_sort Interactions between contact lenses and lens care solutions: Influence in optical properties
author Alves, Micael
author_facet Alves, Micael
Castanheira, Elisabete M. S.
Lira, Madalena
author_role author
author2 Castanheira, Elisabete M. S.
Lira, Madalena
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Alves, Micael
Castanheira, Elisabete M. S.
Lira, Madalena
dc.subject.por.fl_str_mv Contact lenses
Lens care solutions
Ultraviolet radiation
Visible spectra
Transmittance
Fluorescence
Ciências Naturais::Ciências Físicas
Science & Technology
topic Contact lenses
Lens care solutions
Ultraviolet radiation
Visible spectra
Transmittance
Fluorescence
Ciências Naturais::Ciências Físicas
Science & Technology
description Purpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior.
publishDate 2021
dc.date.none.fl_str_mv 2021-09
2021-09-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/78313
url https://hdl.handle.net/1822/78313
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Alves, M., Castanheira, E. M. S., & Lira, M. (2021, October). Interactions between contact lenses and lens care solutions: Influence in optical properties. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2021.01.009
1367-0484
10.1016/j.clae.2021.01.009
33579643
https://linkinghub.elsevier.com/retrieve/pii/S136704842100014X
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595985830346752