Interactions between contact lenses and lens care solutions: Influence in optical properties
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/1822/78313 |
Summary: | Purpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior. |
id |
RCAP_65acd59b9f06c6cfc40643612d2ab56e |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/78313 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Interactions between contact lenses and lens care solutions: Influence in optical propertiesContact lensesLens care solutionsUltraviolet radiationVisible spectraTransmittanceFluorescenceCiências Naturais::Ciências FísicasScience & TechnologyPurpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior.This work was supported by the Portuguese Foundation for Science and Technology (FCT-Portugal) in the framework of the Strategic Funding of CF-UM-UP (UIDB/04650/2020) .ElsevierUniversidade do MinhoAlves, MicaelCastanheira, Elisabete M. S.Lira, Madalena2021-092021-09-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://hdl.handle.net/1822/78313engAlves, M., Castanheira, E. M. S., & Lira, M. (2021, October). Interactions between contact lenses and lens care solutions: Influence in optical properties. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2021.01.0091367-048410.1016/j.clae.2021.01.00933579643https://linkinghub.elsevier.com/retrieve/pii/S136704842100014Xinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T05:23:59Zoai:repositorium.sdum.uminho.pt:1822/78313Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:30:28.842631Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
title |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
spellingShingle |
Interactions between contact lenses and lens care solutions: Influence in optical properties Alves, Micael Contact lenses Lens care solutions Ultraviolet radiation Visible spectra Transmittance Fluorescence Ciências Naturais::Ciências Físicas Science & Technology |
title_short |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
title_full |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
title_fullStr |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
title_full_unstemmed |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
title_sort |
Interactions between contact lenses and lens care solutions: Influence in optical properties |
author |
Alves, Micael |
author_facet |
Alves, Micael Castanheira, Elisabete M. S. Lira, Madalena |
author_role |
author |
author2 |
Castanheira, Elisabete M. S. Lira, Madalena |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Alves, Micael Castanheira, Elisabete M. S. Lira, Madalena |
dc.subject.por.fl_str_mv |
Contact lenses Lens care solutions Ultraviolet radiation Visible spectra Transmittance Fluorescence Ciências Naturais::Ciências Físicas Science & Technology |
topic |
Contact lenses Lens care solutions Ultraviolet radiation Visible spectra Transmittance Fluorescence Ciências Naturais::Ciências Físicas Science & Technology |
description |
Purpose: Investigate changes in optical properties of contact lenses materials (transmittance and reflectance) and lens care solutions (absorption and fluorescence) resulting from its interaction. Methods: From an experimental study, triplicate measurements of transmittance and reflectance of five contact lenses (Senofilcon A, Lotrafilcon B, Balafilcon A, Comfilcon A, and Omafilcon A), as well as UV-vis absorption and fluorescence of four lens care solutions (LCS) (ReNu MultiPlus, Biotrue, OPTI-FREE PureMoist, and AOSept Plus), were evaluated before and after 8 h, one day and one week in storage. The outcomes were provided by Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere, between 200-700 nm, and SPEX-Fluorolog 2 FL3-22 spectrofluorometer. Results: All variables exhibited statistically significant differences over time. Comfilcon A showed the lowest ultraviolet radiation (UVR) A & B attenuation. Balafilcon A and Lotrafilcon B displayed a slight suppression of UVR. Senofilcon A was effective in UVR protection and showed less effect on the fluorescence of lens care solutions. Overall, the reflectance decreased after storage (p < 0.05). AOSept Plus absorbance and fluorescence demonstrated lower interactions than multipurpose solutions (MPS), and Lotrafilcon B induced more remarkable changes in optical properties of LCS than the other materials. Conclusion: The findings suggest that optical variables of lens care solutions and contact lenses changed mutually after storage, probably associated with biochemical and biophysical interactions between components and the release of some polymer compounds. These findings can provide additional information about the interaction of CL materials and LCS in clinical behavior. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-09 2021-09-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/78313 |
url |
https://hdl.handle.net/1822/78313 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Alves, M., Castanheira, E. M. S., & Lira, M. (2021, October). Interactions between contact lenses and lens care solutions: Influence in optical properties. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2021.01.009 1367-0484 10.1016/j.clae.2021.01.009 33579643 https://linkinghub.elsevier.com/retrieve/pii/S136704842100014X |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833595985830346752 |