Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis

Bibliographic Details
Main Author: Mesquita, D. P.
Publication Date: 2016
Other Authors: Amaral, A. L., Ferreira, Eugénio C.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/1822/37914
Summary: Abstract The efficiency of an activated sludge system is generally evaluated by determining several key parameters related to organic matter removal, nitrification and/or denitrification processes. Off-line methods for the determination of these parameters are commonly labor, time consuming, and environmentally harmful. In contrast, quantitative image analysis (QIA) has been recognized as a prompt method for assessing activated sludge contents and structure. In the present study an activated sludge system was operated under different experimental conditions leading to a variety of operational data. Key parameters such as chemical oxygen demand (COD) and ammonium (N-NH4+), and nitrate (N-NO3-) concentrations, throughout the experimental periods, were measured by classical analytical techniques. QIA was further used for the microbial community characterization. Partial Least Squares (PLS) models were used to correlate QIA information and the aforementioned key parameters. It was found that the use of the morphological and physiological data allowed predicting, at some extent, the effluent COD, N-NH4+, and N-NO3- concentrations based on chemometric techniques.
id RCAP_657e37fc76709f544139f67842571f9c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/37914
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Estimation of effluent quality parameters from an activated sludge system using quantitative image analysisWastewater TreatmentActivated sludgeQuantitative Image Analysis (QIA)MorphologyPhysiologyPartial Least Squares (PLS)Partial least squares (PIS)Science & TechnologyAbstract The efficiency of an activated sludge system is generally evaluated by determining several key parameters related to organic matter removal, nitrification and/or denitrification processes. Off-line methods for the determination of these parameters are commonly labor, time consuming, and environmentally harmful. In contrast, quantitative image analysis (QIA) has been recognized as a prompt method for assessing activated sludge contents and structure. In the present study an activated sludge system was operated under different experimental conditions leading to a variety of operational data. Key parameters such as chemical oxygen demand (COD) and ammonium (N-NH4+), and nitrate (N-NO3-) concentrations, throughout the experimental periods, were measured by classical analytical techniques. QIA was further used for the microbial community characterization. Partial Least Squares (PLS) models were used to correlate QIA information and the aforementioned key parameters. It was found that the use of the morphological and physiological data allowed predicting, at some extent, the effluent COD, N-NH4+, and N-NO3- concentrations based on chemometric techniques.The authors thank the FCT Strategic Project of UID/BIO/04469/2013 unit and the project RECI/BBB-EBI/0179/2012 (FCOMP-01-0124-FEDER-027462). The authors also acknowledge the financial support to Daniela P. Mesquita through the postdoctoral Grant (SFRH/BPD/82558/2011) provided by FCT - Portugal.Elsevier B.V.Universidade do MinhoMesquita, D. P.Amaral, A. L.Ferreira, Eugénio C.2016-022016-02-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/37914engMesquita, D. P.; Amaral, A. L.; Ferreira, E. C., Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis. Chemical Engineering Journal, 285, 349-357, 20161385-89471385-894710.1016/j.cej.2015.09.110http://www.elsevier.com/locate/issn/13858947info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T04:00:32Zoai:repositorium.sdum.uminho.pt:1822/37914Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T14:48:19.010348Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
title Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
spellingShingle Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
Mesquita, D. P.
Wastewater Treatment
Activated sludge
Quantitative Image Analysis (QIA)
Morphology
Physiology
Partial Least Squares (PLS)
Partial least squares (PIS)
Science & Technology
title_short Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
title_full Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
title_fullStr Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
title_full_unstemmed Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
title_sort Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis
author Mesquita, D. P.
author_facet Mesquita, D. P.
Amaral, A. L.
Ferreira, Eugénio C.
author_role author
author2 Amaral, A. L.
Ferreira, Eugénio C.
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Mesquita, D. P.
Amaral, A. L.
Ferreira, Eugénio C.
dc.subject.por.fl_str_mv Wastewater Treatment
Activated sludge
Quantitative Image Analysis (QIA)
Morphology
Physiology
Partial Least Squares (PLS)
Partial least squares (PIS)
Science & Technology
topic Wastewater Treatment
Activated sludge
Quantitative Image Analysis (QIA)
Morphology
Physiology
Partial Least Squares (PLS)
Partial least squares (PIS)
Science & Technology
description Abstract The efficiency of an activated sludge system is generally evaluated by determining several key parameters related to organic matter removal, nitrification and/or denitrification processes. Off-line methods for the determination of these parameters are commonly labor, time consuming, and environmentally harmful. In contrast, quantitative image analysis (QIA) has been recognized as a prompt method for assessing activated sludge contents and structure. In the present study an activated sludge system was operated under different experimental conditions leading to a variety of operational data. Key parameters such as chemical oxygen demand (COD) and ammonium (N-NH4+), and nitrate (N-NO3-) concentrations, throughout the experimental periods, were measured by classical analytical techniques. QIA was further used for the microbial community characterization. Partial Least Squares (PLS) models were used to correlate QIA information and the aforementioned key parameters. It was found that the use of the morphological and physiological data allowed predicting, at some extent, the effluent COD, N-NH4+, and N-NO3- concentrations based on chemometric techniques.
publishDate 2016
dc.date.none.fl_str_mv 2016-02
2016-02-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/37914
url https://hdl.handle.net/1822/37914
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Mesquita, D. P.; Amaral, A. L.; Ferreira, E. C., Estimation of effluent quality parameters from an activated sludge system using quantitative image analysis. Chemical Engineering Journal, 285, 349-357, 2016
1385-8947
1385-8947
10.1016/j.cej.2015.09.110
http://www.elsevier.com/locate/issn/13858947
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833594897968398336