Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2019 |
| Outros Autores: | , , , , , , , , |
| Tipo de documento: | Artigo |
| Idioma: | eng |
| Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Texto Completo: | http://hdl.handle.net/1822/62227 |
Resumo: | A new method based on reverse-phase HPLC combined with photodiode array (PDA) was developed to quantify the release of trans-resveratrol (tRES) from solid lipid nanoparticles (SLN). The mobile phase was composed of 75:0:25 (V/V) water/methanol/acetonitrile at 03.5 min, 32.5:30.0:37.5 (V/V) water/methanol/acetonitrile at 3.65.8 min, and 75:0:25 (V/V) water/methanol/acetonitrile at 5.910 min. The flow rate was set at 1.0mL/min, and tRES was detected at the wavelength of 306.6 nm. A concentration range of 1100 µg/mL was used to obtain the linear calibration curve. SLN were produced by ultrasound technique to load 0.1% (wt/wt) of tRES, and the in vitro release of the drug was run in modified Franz diffusion cells. The mean recovery of tRES was found to be 96.84 ± 0.32%. The intra-assay and inter-assay coefficients of variation were less than 5%. The proposed method was applied to in vitro permeability studies, and the Weibull model was found to be the one that best fits the tRES release, which is characterized by a simultaneous lipid chain relaxation and erosion during drug release. |
| id |
RCAP_5fb3be2003015544642d9f1cda8ee4fc |
|---|---|
| oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/62227 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode arraytrans-resveratrolnanotechnologysolid lipid nanoparticleshigh-performance liquid chromatographyScience & TechnologyA new method based on reverse-phase HPLC combined with photodiode array (PDA) was developed to quantify the release of trans-resveratrol (tRES) from solid lipid nanoparticles (SLN). The mobile phase was composed of 75:0:25 (V/V) water/methanol/acetonitrile at 03.5 min, 32.5:30.0:37.5 (V/V) water/methanol/acetonitrile at 3.65.8 min, and 75:0:25 (V/V) water/methanol/acetonitrile at 5.910 min. The flow rate was set at 1.0mL/min, and tRES was detected at the wavelength of 306.6 nm. A concentration range of 1100 µg/mL was used to obtain the linear calibration curve. SLN were produced by ultrasound technique to load 0.1% (wt/wt) of tRES, and the in vitro release of the drug was run in modified Franz diffusion cells. The mean recovery of tRES was found to be 96.84 ± 0.32%. The intra-assay and inter-assay coefficients of variation were less than 5%. The proposed method was applied to in vitro permeability studies, and the Weibull model was found to be the one that best fits the tRES release, which is characterized by a simultaneous lipid chain relaxation and erosion during drug release.The authors wish to acknowledge the financial support from CAPES (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior) and FAPESP (Fundação de Amparo à Pesquisa do Estado de São Paulo). The financial support was also received from The Portuguese Science and Technology Foundation (FCT/MCT) and from European Funds (PRODER/COMPETE) under the project M-ERA-NET-0004/2015-PAIRED, co-financed by FEDER, under the Partnership Agreement PT2020. Authors also thank the support of the project: Nutraceutica come supporto nutrizionale nel paziente oncologico; CUP: B83D18000140007.info:eu-repo/semantics/publishedVersionMDPIUniversidade do MinhoRigon, Roberta B.Fachinetti, NaiaraSeverino, PatríciaDurazzo, AlessandraLucarini, MassimoAtanasov, Atanas G.El Mamouni, SoukainaChorilli, MarlusSantini, AntonelloSouto, Eliana B.20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/62227engRigon, Roberta B.; Fachinetti, Naiara; Severino, Patrícia; Durazzo, Alessandra; Lucarini, Massimo; Atanasov, Atanas G.; El Mamouni, Soukaina; Chorilli, Marlus; Santini, Antonello; Souto, Eliana, Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array. Applied Sciences-Basel, 9(22), 4961, 2019207634172076-341710.3390/app9224961http://www.mdpi.com/journal/applsciinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T04:25:44Zoai:repositorium.sdum.uminho.pt:1822/62227Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T14:48:09.309110Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| title |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| spellingShingle |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array Rigon, Roberta B. trans-resveratrol nanotechnology solid lipid nanoparticles high-performance liquid chromatography Science & Technology |
| title_short |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| title_full |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| title_fullStr |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| title_full_unstemmed |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| title_sort |
Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array |
| author |
Rigon, Roberta B. |
| author_facet |
Rigon, Roberta B. Fachinetti, Naiara Severino, Patrícia Durazzo, Alessandra Lucarini, Massimo Atanasov, Atanas G. El Mamouni, Soukaina Chorilli, Marlus Santini, Antonello Souto, Eliana B. |
| author_role |
author |
| author2 |
Fachinetti, Naiara Severino, Patrícia Durazzo, Alessandra Lucarini, Massimo Atanasov, Atanas G. El Mamouni, Soukaina Chorilli, Marlus Santini, Antonello Souto, Eliana B. |
| author2_role |
author author author author author author author author author |
| dc.contributor.none.fl_str_mv |
Universidade do Minho |
| dc.contributor.author.fl_str_mv |
Rigon, Roberta B. Fachinetti, Naiara Severino, Patrícia Durazzo, Alessandra Lucarini, Massimo Atanasov, Atanas G. El Mamouni, Soukaina Chorilli, Marlus Santini, Antonello Souto, Eliana B. |
| dc.subject.por.fl_str_mv |
trans-resveratrol nanotechnology solid lipid nanoparticles high-performance liquid chromatography Science & Technology |
| topic |
trans-resveratrol nanotechnology solid lipid nanoparticles high-performance liquid chromatography Science & Technology |
| description |
A new method based on reverse-phase HPLC combined with photodiode array (PDA) was developed to quantify the release of trans-resveratrol (tRES) from solid lipid nanoparticles (SLN). The mobile phase was composed of 75:0:25 (V/V) water/methanol/acetonitrile at 03.5 min, 32.5:30.0:37.5 (V/V) water/methanol/acetonitrile at 3.65.8 min, and 75:0:25 (V/V) water/methanol/acetonitrile at 5.910 min. The flow rate was set at 1.0mL/min, and tRES was detected at the wavelength of 306.6 nm. A concentration range of 1100 µg/mL was used to obtain the linear calibration curve. SLN were produced by ultrasound technique to load 0.1% (wt/wt) of tRES, and the in vitro release of the drug was run in modified Franz diffusion cells. The mean recovery of tRES was found to be 96.84 ± 0.32%. The intra-assay and inter-assay coefficients of variation were less than 5%. The proposed method was applied to in vitro permeability studies, and the Weibull model was found to be the one that best fits the tRES release, which is characterized by a simultaneous lipid chain relaxation and erosion during drug release. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 2019-01-01T00:00:00Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/62227 |
| url |
http://hdl.handle.net/1822/62227 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
Rigon, Roberta B.; Fachinetti, Naiara; Severino, Patrícia; Durazzo, Alessandra; Lucarini, Massimo; Atanasov, Atanas G.; El Mamouni, Soukaina; Chorilli, Marlus; Santini, Antonello; Souto, Eliana, Quantification of trans-resveratrol-loaded solid lipid nanoparticles by a validated reverse-phase HPLC photodiode array. Applied Sciences-Basel, 9(22), 4961, 2019 20763417 2076-3417 10.3390/app9224961 http://www.mdpi.com/journal/applsci |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833594896035872768 |