Use of Etonogestrel Implant Beyond Approved Duration – A Case Report

Bibliographic Details
Main Author: Castro Carvalho, C
Publication Date: 2022
Other Authors: Silveira Reis, I, Machado, AI
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.17/4174
Summary: The contraceptive implant is the most effective method of reversible contraception. Observational and trial data indicate that this method remains effective beyond the initially approved duration of use. We report a case of etonogestrel serum levels above the supposed threshold value for ovulation suppression nine years after implant insertion.
id RCAP_4da3c2e7c357fbb26d65fe82307afc8d
oai_identifier_str oai:repositorio.chlc.pt:10400.17/4174
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Use of Etonogestrel Implant Beyond Approved Duration – A Case ReportUso do Implante de Etonogestrel Além da Duração Aprovada – Um Caso ClínicoEtonogestrel implantContraceptive effectivenessNexplanon®Implanon NXT®Family planningMAC GINThe contraceptive implant is the most effective method of reversible contraception. Observational and trial data indicate that this method remains effective beyond the initially approved duration of use. We report a case of etonogestrel serum levels above the supposed threshold value for ovulation suppression nine years after implant insertion.Federação das Sociedades Portuguesas de Obstetrícia e GinecologiaRepositório da Unidade Local de Saúde São JoséCastro Carvalho, CSilveira Reis, IMachado, AI2022-07-29T14:55:15Z20222022-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/4174enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-06T16:48:14Zoai:repositorio.chlc.pt:10400.17/4174Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:19:12.184755Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
Uso do Implante de Etonogestrel Além da Duração Aprovada – Um Caso Clínico
title Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
spellingShingle Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
Castro Carvalho, C
Etonogestrel implant
Contraceptive effectiveness
Nexplanon®
Implanon NXT®
Family planning
MAC GIN
title_short Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
title_full Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
title_fullStr Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
title_full_unstemmed Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
title_sort Use of Etonogestrel Implant Beyond Approved Duration – A Case Report
author Castro Carvalho, C
author_facet Castro Carvalho, C
Silveira Reis, I
Machado, AI
author_role author
author2 Silveira Reis, I
Machado, AI
author2_role author
author
dc.contributor.none.fl_str_mv Repositório da Unidade Local de Saúde São José
dc.contributor.author.fl_str_mv Castro Carvalho, C
Silveira Reis, I
Machado, AI
dc.subject.por.fl_str_mv Etonogestrel implant
Contraceptive effectiveness
Nexplanon®
Implanon NXT®
Family planning
MAC GIN
topic Etonogestrel implant
Contraceptive effectiveness
Nexplanon®
Implanon NXT®
Family planning
MAC GIN
description The contraceptive implant is the most effective method of reversible contraception. Observational and trial data indicate that this method remains effective beyond the initially approved duration of use. We report a case of etonogestrel serum levels above the supposed threshold value for ovulation suppression nine years after implant insertion.
publishDate 2022
dc.date.none.fl_str_mv 2022-07-29T14:55:15Z
2022
2022-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/4174
url http://hdl.handle.net/10400.17/4174
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Federação das Sociedades Portuguesas de Obstetrícia e Ginecologia
publisher.none.fl_str_mv Federação das Sociedades Portuguesas de Obstetrícia e Ginecologia
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600486509379584