CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis

Bibliographic Details
Main Author: Sousa, JA
Publication Date: 2024
Other Authors: Sondermann, A, Bernardo-Castro, S, Varela, R, Donato, H, Sargento-Freitas, J
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.4/2344
Summary: Background: The optimal imaging method for detecting distal medium vessel occlusions (DMVOs) remains undefined. Purpose: The objective of this study is to compare the diagnostic performance of CTA with CTP in detecting DMVOs. Data sources: We searched PubMed, EMBASE, Web of Science Core Collection, and Cochrane Central Register of Controlled Trials up to March 31, 2023 (PROSPERO: CRD42022344006). Study selection: A total of 12 studies reporting accuracy values of CTA and/or CTP were included, comprising 2607 patients with 479 cases (18.3%) of DMVOs. Data analysis: Pooled sensitivity and specificity of both imaging methods were compared using a random-effects model. Subgroup analyses were performed based on the technique used in CTA (multi or single-phase) and the subtype of DMVOs (M2-only vs. M2 and other DMVOs). We applied Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool and Grading of Recommendations, Assessment, Development and Evaluation (GRADE) quality assessment criteria. Data synthesis: CTA demonstrated significantly lower sensitivity compared to CTP in detecting DMVOs [0.74, 95%CI (0.63-0.82) vs. 0.89, 95% CI (0.82-0.93), P < 0.01]. When subgrouped into single-phase and multi-phase CTA, multi-phase CTA exhibited higher sensitivity for DMVO detection than single-phase CTA [0.91, 95%CI (0.85-0.94) vs. 0.64, 95%CI (0.56-0.71), P < .01], while reaching similar levels to CTP. The sensitivity of single-phase CTA substantially decreased when extending from M2 to other non-M2 DMVOs [0.74, 95%CI (0.63-0.83) vs. 0.61, 0.95%CI (0.53-0.68), P = .02]. Limitations: We identified an overall high risk of bias and low quality of evidence, attributable to the design and reference standards of most studies. Conclusions: Our findings highlight a significantly lower sensitivity of single-phase CTA compared to multi-phase CTA and CTP in diagnosing DMVOs.
id RCAP_41f54c97d64f75f49dcf5d98ec7912e1
oai_identifier_str oai:rihuc.huc.min-saude.pt:10400.4/2344
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysisIsquemia Cerebral/diagnóstico por imagemAVC IsquémicoBackground: The optimal imaging method for detecting distal medium vessel occlusions (DMVOs) remains undefined. Purpose: The objective of this study is to compare the diagnostic performance of CTA with CTP in detecting DMVOs. Data sources: We searched PubMed, EMBASE, Web of Science Core Collection, and Cochrane Central Register of Controlled Trials up to March 31, 2023 (PROSPERO: CRD42022344006). Study selection: A total of 12 studies reporting accuracy values of CTA and/or CTP were included, comprising 2607 patients with 479 cases (18.3%) of DMVOs. Data analysis: Pooled sensitivity and specificity of both imaging methods were compared using a random-effects model. Subgroup analyses were performed based on the technique used in CTA (multi or single-phase) and the subtype of DMVOs (M2-only vs. M2 and other DMVOs). We applied Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool and Grading of Recommendations, Assessment, Development and Evaluation (GRADE) quality assessment criteria. Data synthesis: CTA demonstrated significantly lower sensitivity compared to CTP in detecting DMVOs [0.74, 95%CI (0.63-0.82) vs. 0.89, 95% CI (0.82-0.93), P < 0.01]. When subgrouped into single-phase and multi-phase CTA, multi-phase CTA exhibited higher sensitivity for DMVO detection than single-phase CTA [0.91, 95%CI (0.85-0.94) vs. 0.64, 95%CI (0.56-0.71), P < .01], while reaching similar levels to CTP. The sensitivity of single-phase CTA substantially decreased when extending from M2 to other non-M2 DMVOs [0.74, 95%CI (0.63-0.83) vs. 0.61, 0.95%CI (0.53-0.68), P = .02]. Limitations: We identified an overall high risk of bias and low quality of evidence, attributable to the design and reference standards of most studies. Conclusions: Our findings highlight a significantly lower sensitivity of single-phase CTA compared to multi-phase CTA and CTP in diagnosing DMVOs.RIHUCSousa, JASondermann, ABernardo-Castro, SVarela, RDonato, HSargento-Freitas, J2024-01-08T14:31:32Z20242024-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.4/2344eng10.3174/ajnr.A8080info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-01-30T03:22:52Zoai:rihuc.huc.min-saude.pt:10400.4/2344Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T19:45:06.876483Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
title CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
spellingShingle CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
Sousa, JA
Isquemia Cerebral/diagnóstico por imagem
AVC Isquémico
title_short CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
title_full CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
title_fullStr CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
title_full_unstemmed CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
title_sort CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
author Sousa, JA
author_facet Sousa, JA
Sondermann, A
Bernardo-Castro, S
Varela, R
Donato, H
Sargento-Freitas, J
author_role author
author2 Sondermann, A
Bernardo-Castro, S
Varela, R
Donato, H
Sargento-Freitas, J
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv RIHUC
dc.contributor.author.fl_str_mv Sousa, JA
Sondermann, A
Bernardo-Castro, S
Varela, R
Donato, H
Sargento-Freitas, J
dc.subject.por.fl_str_mv Isquemia Cerebral/diagnóstico por imagem
AVC Isquémico
topic Isquemia Cerebral/diagnóstico por imagem
AVC Isquémico
description Background: The optimal imaging method for detecting distal medium vessel occlusions (DMVOs) remains undefined. Purpose: The objective of this study is to compare the diagnostic performance of CTA with CTP in detecting DMVOs. Data sources: We searched PubMed, EMBASE, Web of Science Core Collection, and Cochrane Central Register of Controlled Trials up to March 31, 2023 (PROSPERO: CRD42022344006). Study selection: A total of 12 studies reporting accuracy values of CTA and/or CTP were included, comprising 2607 patients with 479 cases (18.3%) of DMVOs. Data analysis: Pooled sensitivity and specificity of both imaging methods were compared using a random-effects model. Subgroup analyses were performed based on the technique used in CTA (multi or single-phase) and the subtype of DMVOs (M2-only vs. M2 and other DMVOs). We applied Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool and Grading of Recommendations, Assessment, Development and Evaluation (GRADE) quality assessment criteria. Data synthesis: CTA demonstrated significantly lower sensitivity compared to CTP in detecting DMVOs [0.74, 95%CI (0.63-0.82) vs. 0.89, 95% CI (0.82-0.93), P < 0.01]. When subgrouped into single-phase and multi-phase CTA, multi-phase CTA exhibited higher sensitivity for DMVO detection than single-phase CTA [0.91, 95%CI (0.85-0.94) vs. 0.64, 95%CI (0.56-0.71), P < .01], while reaching similar levels to CTP. The sensitivity of single-phase CTA substantially decreased when extending from M2 to other non-M2 DMVOs [0.74, 95%CI (0.63-0.83) vs. 0.61, 0.95%CI (0.53-0.68), P = .02]. Limitations: We identified an overall high risk of bias and low quality of evidence, attributable to the design and reference standards of most studies. Conclusions: Our findings highlight a significantly lower sensitivity of single-phase CTA compared to multi-phase CTA and CTP in diagnosing DMVOs.
publishDate 2024
dc.date.none.fl_str_mv 2024-01-08T14:31:32Z
2024
2024-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.4/2344
url http://hdl.handle.net/10400.4/2344
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.3174/ajnr.A8080
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833598301130194944