Use of an acoustic wave sensor to follow lead absorption by porcine skin
Main Author: | |
---|---|
Publication Date: | 2008 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/10316/5030 https://doi.org/10.1016/j.snb.2007.07.011 |
Summary: | A new acoustic wave sensor capable of detecting and quantifying lead is presented, and fully characterized in terms of sensitivity, selectivity, and linear calibration range. The sensor was used to quantify lead absorption by pig stratum corneum and to follow in real time, both the absorption and desorption of lead by the skin. Values of lead absorption of 29.6 mg Pb2+/g of stratum corneum were obtained. Lead in solution was also quantified by atomic absorption spectrometry (AAS). The results obtained by both methods, AAS and the sensor, were compared and no statistical differences in the accuracy and precision of the results were found. |
id |
RCAP_41bf1683e64e584fbb9a4b967c4cc1f9 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/5030 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Use of an acoustic wave sensor to follow lead absorption by porcine skinBulk acoustic wave sensorStratum corneumA new acoustic wave sensor capable of detecting and quantifying lead is presented, and fully characterized in terms of sensitivity, selectivity, and linear calibration range. The sensor was used to quantify lead absorption by pig stratum corneum and to follow in real time, both the absorption and desorption of lead by the skin. Values of lead absorption of 29.6 mg Pb2+/g of stratum corneum were obtained. Lead in solution was also quantified by atomic absorption spectrometry (AAS). The results obtained by both methods, AAS and the sensor, were compared and no statistical differences in the accuracy and precision of the results were found.http://www.sciencedirect.com/science/article/B6THH-4P4NPG3-2/1/5b7ff13690528fc99df11246c971c2662008info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttps://hdl.handle.net/10316/5030https://hdl.handle.net/10316/5030https://doi.org/10.1016/j.snb.2007.07.011engSensors and Actuators B: Chemical. 128:2 (2008) 450-454Veríssimo, Marta I. S.Pais, Alberto A. C. C.Oliveira, João A. B. P.Gomes, M. Teresa S. R.info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2020-11-06T16:59:18Zoai:estudogeral.uc.pt:10316/5030Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:24:07.308615Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
title |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
spellingShingle |
Use of an acoustic wave sensor to follow lead absorption by porcine skin Veríssimo, Marta I. S. Bulk acoustic wave sensor Stratum corneum |
title_short |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
title_full |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
title_fullStr |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
title_full_unstemmed |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
title_sort |
Use of an acoustic wave sensor to follow lead absorption by porcine skin |
author |
Veríssimo, Marta I. S. |
author_facet |
Veríssimo, Marta I. S. Pais, Alberto A. C. C. Oliveira, João A. B. P. Gomes, M. Teresa S. R. |
author_role |
author |
author2 |
Pais, Alberto A. C. C. Oliveira, João A. B. P. Gomes, M. Teresa S. R. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Veríssimo, Marta I. S. Pais, Alberto A. C. C. Oliveira, João A. B. P. Gomes, M. Teresa S. R. |
dc.subject.por.fl_str_mv |
Bulk acoustic wave sensor Stratum corneum |
topic |
Bulk acoustic wave sensor Stratum corneum |
description |
A new acoustic wave sensor capable of detecting and quantifying lead is presented, and fully characterized in terms of sensitivity, selectivity, and linear calibration range. The sensor was used to quantify lead absorption by pig stratum corneum and to follow in real time, both the absorption and desorption of lead by the skin. Values of lead absorption of 29.6 mg Pb2+/g of stratum corneum were obtained. Lead in solution was also quantified by atomic absorption spectrometry (AAS). The results obtained by both methods, AAS and the sensor, were compared and no statistical differences in the accuracy and precision of the results were found. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10316/5030 https://hdl.handle.net/10316/5030 https://doi.org/10.1016/j.snb.2007.07.011 |
url |
https://hdl.handle.net/10316/5030 https://doi.org/10.1016/j.snb.2007.07.011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Sensors and Actuators B: Chemical. 128:2 (2008) 450-454 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833602342637797376 |