Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging
| Main Author: | |
|---|---|
| Publication Date: | 2018 |
| Format: | Master thesis |
| Language: | eng |
| Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Download full: | http://hdl.handle.net/10362/59605 |
Summary: | Cancer is the second leading cause of death in the world, and therefore, there is an undeniable need to ensure early screening and detection systems worldwide. The aim of this project is to study the feasibility of a Cone Beam Computed Tomography (CBCT) scanner for simultaneous breast and lung imaging. Additionally, the development of reconstruction algorithms and the study of their impact to the image quality was considered. Monte Carlo (MC) simulations were performed using the PENELOPE code system. A MC geometry model of a CBCT scanner was implemented for energies of 30 keV and 80 keV for hypothetical scanning protocols. Microcalcifications were inserted into the breast and lung of the computational phantom (ICRP Adult Female Reference), used in the simulations for dose assessment and projection acquisition. Reconstructed images were analyzed in terms of the Contrast-to-Noise Ratio (CNR) and dose calculations were performed for two protocols, one with a normalization factor of 2 mGy in the breast and another with 5 mGy in the lungs. Both, MC geometry model and reconstruction algorithm were validated by means of on-field measurements and data acquisition in a clinical center. Dosimetric and imaging performances were evaluated through Quality Assurance phantoms (Computed Tomography Dose Index and Catphan, respectively). Results indicate that the best implementation of the reconstruction algorithm was achieved with 80 keV, using the Hanning filter and linear interpolation. More specifically, for a spherical lung lesion with a radius of 7 mm a 30% CNR gain was found when the number of projections varied from 12 to 36 (corresponding to a dose increase of a factor of 3). This research suggests the possibility of developing a CBCT modulated beam scanner for simultaneous breast and lung imaging while ensuring dose reduction. However further investigation regarding the number of projections needed for image reconstruction is required. |
| id |
RCAP_4089ad77657f7f10727f72b94ffc8ddf |
|---|---|
| oai_identifier_str |
oai:run.unl.pt:10362/59605 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imagingCone Beam Computed TomographyCancer DetectionMonte Carlo SimulationOrgan DoseMedical Image ReconstructionLung and Breast ImagingDomínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e TecnologiasCancer is the second leading cause of death in the world, and therefore, there is an undeniable need to ensure early screening and detection systems worldwide. The aim of this project is to study the feasibility of a Cone Beam Computed Tomography (CBCT) scanner for simultaneous breast and lung imaging. Additionally, the development of reconstruction algorithms and the study of their impact to the image quality was considered. Monte Carlo (MC) simulations were performed using the PENELOPE code system. A MC geometry model of a CBCT scanner was implemented for energies of 30 keV and 80 keV for hypothetical scanning protocols. Microcalcifications were inserted into the breast and lung of the computational phantom (ICRP Adult Female Reference), used in the simulations for dose assessment and projection acquisition. Reconstructed images were analyzed in terms of the Contrast-to-Noise Ratio (CNR) and dose calculations were performed for two protocols, one with a normalization factor of 2 mGy in the breast and another with 5 mGy in the lungs. Both, MC geometry model and reconstruction algorithm were validated by means of on-field measurements and data acquisition in a clinical center. Dosimetric and imaging performances were evaluated through Quality Assurance phantoms (Computed Tomography Dose Index and Catphan, respectively). Results indicate that the best implementation of the reconstruction algorithm was achieved with 80 keV, using the Hanning filter and linear interpolation. More specifically, for a spherical lung lesion with a radius of 7 mm a 30% CNR gain was found when the number of projections varied from 12 to 36 (corresponding to a dose increase of a factor of 3). This research suggests the possibility of developing a CBCT modulated beam scanner for simultaneous breast and lung imaging while ensuring dose reduction. However further investigation regarding the number of projections needed for image reconstruction is required.Di Maria, SalvatoreMatela, NunoVaz, JoséRUNAntónio, Débora de Souza2019-02-05T13:55:10Z2018-1220182018-12-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10362/59605enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-22T17:37:02Zoai:run.unl.pt:10362/59605Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T17:08:06.906082Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| title |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| spellingShingle |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging António, Débora de Souza Cone Beam Computed Tomography Cancer Detection Monte Carlo Simulation Organ Dose Medical Image Reconstruction Lung and Breast Imaging Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias |
| title_short |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| title_full |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| title_fullStr |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| title_full_unstemmed |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| title_sort |
Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging |
| author |
António, Débora de Souza |
| author_facet |
António, Débora de Souza |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Di Maria, Salvatore Matela, Nuno Vaz, José RUN |
| dc.contributor.author.fl_str_mv |
António, Débora de Souza |
| dc.subject.por.fl_str_mv |
Cone Beam Computed Tomography Cancer Detection Monte Carlo Simulation Organ Dose Medical Image Reconstruction Lung and Breast Imaging Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias |
| topic |
Cone Beam Computed Tomography Cancer Detection Monte Carlo Simulation Organ Dose Medical Image Reconstruction Lung and Breast Imaging Domínio/Área Científica::Engenharia e Tecnologia::Outras Engenharias e Tecnologias |
| description |
Cancer is the second leading cause of death in the world, and therefore, there is an undeniable need to ensure early screening and detection systems worldwide. The aim of this project is to study the feasibility of a Cone Beam Computed Tomography (CBCT) scanner for simultaneous breast and lung imaging. Additionally, the development of reconstruction algorithms and the study of their impact to the image quality was considered. Monte Carlo (MC) simulations were performed using the PENELOPE code system. A MC geometry model of a CBCT scanner was implemented for energies of 30 keV and 80 keV for hypothetical scanning protocols. Microcalcifications were inserted into the breast and lung of the computational phantom (ICRP Adult Female Reference), used in the simulations for dose assessment and projection acquisition. Reconstructed images were analyzed in terms of the Contrast-to-Noise Ratio (CNR) and dose calculations were performed for two protocols, one with a normalization factor of 2 mGy in the breast and another with 5 mGy in the lungs. Both, MC geometry model and reconstruction algorithm were validated by means of on-field measurements and data acquisition in a clinical center. Dosimetric and imaging performances were evaluated through Quality Assurance phantoms (Computed Tomography Dose Index and Catphan, respectively). Results indicate that the best implementation of the reconstruction algorithm was achieved with 80 keV, using the Hanning filter and linear interpolation. More specifically, for a spherical lung lesion with a radius of 7 mm a 30% CNR gain was found when the number of projections varied from 12 to 36 (corresponding to a dose increase of a factor of 3). This research suggests the possibility of developing a CBCT modulated beam scanner for simultaneous breast and lung imaging while ensuring dose reduction. However further investigation regarding the number of projections needed for image reconstruction is required. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-12 2018 2018-12-01T00:00:00Z 2019-02-05T13:55:10Z |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10362/59605 |
| url |
http://hdl.handle.net/10362/59605 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833596459639898112 |