Positron annihilation lifetime spectroscopy study on epoxy moisture absorption

Detalhes bibliográficos
Autor(a) principal: Gordo, P. M.
Data de Publicação: 2013
Outros Autores: Luís, J. M. M., Marques, M. F. Ferreira, Naia, M. Duarte, Morais, J. J. M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: https://hdl.handle.net/10316/102716
https://doi.org/10.1088/1742-6596/443/1/012055
Resumo: Positron annihilation lifetime spectroscopy was used to study the effect of water uptake on the free volume of a commercial epoxy exposed to atmospheres with relative humidity ranging from 30.5% to 95.8%. The absorption process was also analyzed by gravimetric measurements. When exposed to humidity the mean hole volume remains constant and the number of holes not occupied by water molecules decrease with increasing of both the exposure time and the relative humidity as indicated by the constancy of t3 and the decrease of I3.
id RCAP_3e1f2b5a0077bc915bd6b21dc1e7ea03
oai_identifier_str oai:estudogeral.uc.pt:10316/102716
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Positron annihilation lifetime spectroscopy study on epoxy moisture absorptionPositron annihilation lifetime spectroscopy was used to study the effect of water uptake on the free volume of a commercial epoxy exposed to atmospheres with relative humidity ranging from 30.5% to 95.8%. The absorption process was also analyzed by gravimetric measurements. When exposed to humidity the mean hole volume remains constant and the number of holes not occupied by water molecules decrease with increasing of both the exposure time and the relative humidity as indicated by the constancy of t3 and the decrease of I3.2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://hdl.handle.net/10316/102716https://hdl.handle.net/10316/102716https://doi.org/10.1088/1742-6596/443/1/012055eng1742-6596Gordo, P. M.Luís, J. M. M.Marques, M. F. FerreiraNaia, M. DuarteMorais, J. J. M.info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2023-07-27T08:00:31Zoai:estudogeral.uc.pt:10316/102716Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:52:18.845909Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
title Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
spellingShingle Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
Gordo, P. M.
title_short Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
title_full Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
title_fullStr Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
title_full_unstemmed Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
title_sort Positron annihilation lifetime spectroscopy study on epoxy moisture absorption
author Gordo, P. M.
author_facet Gordo, P. M.
Luís, J. M. M.
Marques, M. F. Ferreira
Naia, M. Duarte
Morais, J. J. M.
author_role author
author2 Luís, J. M. M.
Marques, M. F. Ferreira
Naia, M. Duarte
Morais, J. J. M.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Gordo, P. M.
Luís, J. M. M.
Marques, M. F. Ferreira
Naia, M. Duarte
Morais, J. J. M.
description Positron annihilation lifetime spectroscopy was used to study the effect of water uptake on the free volume of a commercial epoxy exposed to atmospheres with relative humidity ranging from 30.5% to 95.8%. The absorption process was also analyzed by gravimetric measurements. When exposed to humidity the mean hole volume remains constant and the number of holes not occupied by water molecules decrease with increasing of both the exposure time and the relative humidity as indicated by the constancy of t3 and the decrease of I3.
publishDate 2013
dc.date.none.fl_str_mv 2013
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/102716
https://hdl.handle.net/10316/102716
https://doi.org/10.1088/1742-6596/443/1/012055
url https://hdl.handle.net/10316/102716
https://doi.org/10.1088/1742-6596/443/1/012055
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1742-6596
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602501779128320