Export Ready — 

Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis

Bibliographic Details
Main Author: Gama, F
Publication Date: 2020
Other Authors: Ferreira, J, Carmo, J, Costa, FM, Carvalho, S, Carmo, P, Cavaco, D, Morgado, FB, Adragão, P, Mendes, M
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.26/32034
Summary: BACKGROUND Medical therapy for heart failure with reduced ejection fraction evolved since trials validated the use of implantable cardioverter-defibrillators (ICDs). We sought to evaluate the performance of ICDs in reducing mortality in the era of modern medical therapy by means of a systematic review and meta-analysis of contemporary randomized clinical trials of drug therapy for heart failure with reduced ejection fraction. METHODS AND RESULTS We systematically identified randomized clinical trials that evaluated drug therapy in patients with heart failure with reduced ejection fraction that reported mortality. Studies that enrolled <1000 patients, patients with left ventricular ejection fraction >40%, or patients in the acute phase of heart failure and study treatment with devices were excluded. We identified 8 randomized clinical trials, including 31 701 patients of whom 3631 (11.5%) had an ICD. ICDs were associated with a lower risk of all-cause mortality (relative risk [RR], 0.85; 95% CI, 0.78-0.94) and sudden cardiac death (RR, 0.49; 95% CI, 0.40-0.61). Results were consistent among studies published before and after 2010. In meta-regression analysis, the proportion of nonischemic etiology did not affect the associated benefit of ICD. CONCLUSIONS In our meta-analysis of contemporary randomized trials of drug therapy for heart failure with reduced ejection fraction, the rate of ICD use was low and associated with a decreased risk in both all-cause mortality and sudden cardiac death. This benefit was still present in trials with new medical therapy.
id RCAP_3caeb6a24c0d3af4a39dbec3f964f74d
oai_identifier_str oai:comum.rcaap.pt:10400.26/32034
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-AnalysisDesfibrilhadores ImplantáveisInsuficiência Cardíaca/tratamento farmacológicoHeart /drug therapycDefibrillators, ImplantableBACKGROUND Medical therapy for heart failure with reduced ejection fraction evolved since trials validated the use of implantable cardioverter-defibrillators (ICDs). We sought to evaluate the performance of ICDs in reducing mortality in the era of modern medical therapy by means of a systematic review and meta-analysis of contemporary randomized clinical trials of drug therapy for heart failure with reduced ejection fraction. METHODS AND RESULTS We systematically identified randomized clinical trials that evaluated drug therapy in patients with heart failure with reduced ejection fraction that reported mortality. Studies that enrolled <1000 patients, patients with left ventricular ejection fraction >40%, or patients in the acute phase of heart failure and study treatment with devices were excluded. We identified 8 randomized clinical trials, including 31 701 patients of whom 3631 (11.5%) had an ICD. ICDs were associated with a lower risk of all-cause mortality (relative risk [RR], 0.85; 95% CI, 0.78-0.94) and sudden cardiac death (RR, 0.49; 95% CI, 0.40-0.61). Results were consistent among studies published before and after 2010. In meta-regression analysis, the proportion of nonischemic etiology did not affect the associated benefit of ICD. CONCLUSIONS In our meta-analysis of contemporary randomized trials of drug therapy for heart failure with reduced ejection fraction, the rate of ICD use was low and associated with a decreased risk in both all-cause mortality and sudden cardiac death. This benefit was still present in trials with new medical therapy.Repositório ComumGama, FFerreira, JCarmo, JCosta, FMCarvalho, SCarmo, PCavaco, DMorgado, FBAdragão, PMendes, M2020-04-25T21:29:21Z2020-04-212020-04-21T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.26/32034eng10.1161/JAHA.119.015177info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-05-14T12:46:59Zoai:comum.rcaap.pt:10400.26/32034Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T07:18:40.806993Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
title Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
spellingShingle Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
Gama, F
Desfibrilhadores Implantáveis
Insuficiência Cardíaca/tratamento farmacológico
Heart /drug therapy
c
Defibrillators, Implantable
title_short Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
title_full Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
title_fullStr Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
title_full_unstemmed Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
title_sort Implantable Cardioverter-Defibrillators in Trials of Drug Therapy for Heart Failure: A Systematic Review and Meta-Analysis
author Gama, F
author_facet Gama, F
Ferreira, J
Carmo, J
Costa, FM
Carvalho, S
Carmo, P
Cavaco, D
Morgado, FB
Adragão, P
Mendes, M
author_role author
author2 Ferreira, J
Carmo, J
Costa, FM
Carvalho, S
Carmo, P
Cavaco, D
Morgado, FB
Adragão, P
Mendes, M
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Comum
dc.contributor.author.fl_str_mv Gama, F
Ferreira, J
Carmo, J
Costa, FM
Carvalho, S
Carmo, P
Cavaco, D
Morgado, FB
Adragão, P
Mendes, M
dc.subject.por.fl_str_mv Desfibrilhadores Implantáveis
Insuficiência Cardíaca/tratamento farmacológico
Heart /drug therapy
c
Defibrillators, Implantable
topic Desfibrilhadores Implantáveis
Insuficiência Cardíaca/tratamento farmacológico
Heart /drug therapy
c
Defibrillators, Implantable
description BACKGROUND Medical therapy for heart failure with reduced ejection fraction evolved since trials validated the use of implantable cardioverter-defibrillators (ICDs). We sought to evaluate the performance of ICDs in reducing mortality in the era of modern medical therapy by means of a systematic review and meta-analysis of contemporary randomized clinical trials of drug therapy for heart failure with reduced ejection fraction. METHODS AND RESULTS We systematically identified randomized clinical trials that evaluated drug therapy in patients with heart failure with reduced ejection fraction that reported mortality. Studies that enrolled <1000 patients, patients with left ventricular ejection fraction >40%, or patients in the acute phase of heart failure and study treatment with devices were excluded. We identified 8 randomized clinical trials, including 31 701 patients of whom 3631 (11.5%) had an ICD. ICDs were associated with a lower risk of all-cause mortality (relative risk [RR], 0.85; 95% CI, 0.78-0.94) and sudden cardiac death (RR, 0.49; 95% CI, 0.40-0.61). Results were consistent among studies published before and after 2010. In meta-regression analysis, the proportion of nonischemic etiology did not affect the associated benefit of ICD. CONCLUSIONS In our meta-analysis of contemporary randomized trials of drug therapy for heart failure with reduced ejection fraction, the rate of ICD use was low and associated with a decreased risk in both all-cause mortality and sudden cardiac death. This benefit was still present in trials with new medical therapy.
publishDate 2020
dc.date.none.fl_str_mv 2020-04-25T21:29:21Z
2020-04-21
2020-04-21T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.26/32034
url http://hdl.handle.net/10400.26/32034
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1161/JAHA.119.015177
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602947402956800