Development and measurement of the transverse diameter of the fetal cerebellum by MRI

Bibliographic Details
Main Author: Farinha, Cristina
Publication Date: 2014
Other Authors: Tavares, Óscar
Format: Article
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://doi.org/10.25758/set.1064
Summary: Fetal magnetic resonance imaging (MRI) is an effective method in the prenatal evaluation of normal brain morphology and diagnosis of diseases of the central nervous system. It is an important complement to clinical ultrasound. The cerebellum is one of the least affected structures in cases of fetal growth restriction, so it is a good index for evaluating fetal development and gestational age. Thus, biometric evaluation is essential in fetal prenatal diagnosis of brain development. Purpose – Evaluation of the transversal cerebellum diameter (the anatomical structures reference of the fetal central nervous system) and compare it with an international reference study in this regard. Material and methods – The sample consisted of 84 pregnant women who have performed magnetic resonance in a medical imaging clinic in the Centre region. The average considered for evaluating fetal development was the transversal cerebellum diameter. Results – The results for the transversal cerebellum diameter demonstrate the absence of statistically significant mean differences (p>0.05) in the number of weeks of gestation compared with theoretical values measured in the study by Garel. Conclusion – Based on the obtained results we can conclude that the parameter analyzed is consistent with the publication of Catherine Garel – Le développement du cerveau foetal atlas IRM et biometrie.
id RCAP_3c6a596d1dfb76134354cf771baae1fc
oai_identifier_str oai:journals.ipl.pt:article/671
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Development and measurement of the transverse diameter of the fetal cerebellum by MRIDesenvolvimento e mensuração do diâmetro transversal do cerebelo fetal por ressonância magnéticaRessonância magnética fetalCerebeloBiometriaDiâmetro transversalFetal magnetic resonanceCerebellumBiometryTransversal diameterFetal magnetic resonance imaging (MRI) is an effective method in the prenatal evaluation of normal brain morphology and diagnosis of diseases of the central nervous system. It is an important complement to clinical ultrasound. The cerebellum is one of the least affected structures in cases of fetal growth restriction, so it is a good index for evaluating fetal development and gestational age. Thus, biometric evaluation is essential in fetal prenatal diagnosis of brain development. Purpose – Evaluation of the transversal cerebellum diameter (the anatomical structures reference of the fetal central nervous system) and compare it with an international reference study in this regard. Material and methods – The sample consisted of 84 pregnant women who have performed magnetic resonance in a medical imaging clinic in the Centre region. The average considered for evaluating fetal development was the transversal cerebellum diameter. Results – The results for the transversal cerebellum diameter demonstrate the absence of statistically significant mean differences (p>0.05) in the number of weeks of gestation compared with theoretical values measured in the study by Garel. Conclusion – Based on the obtained results we can conclude that the parameter analyzed is consistent with the publication of Catherine Garel – Le développement du cerveau foetal atlas IRM et biometrie.A ressonância magnética fetal é um método eficaz na avaliação pré-natal da morfologia normal do cérebro e no diagnóstico de patologias do sistema nervoso central, sendo um importante complemento clínico à ecografia. O cerebelo é uma das estruturas menos afetadas em casos de restrição de crescimento fetal, tornando-se um bom indicador na avaliação do desenvolvimento fetal e da idade gestacional. Deste modo, a avaliação biométrica fetal é fundamental no diagnóstico pré-natal do desenvolvimento cerebral. Objetivo – Avaliação do diâmetro transversal do cerebelo (estrutura anatómica de referência do sistema nervoso central) do feto e posterior comparação com um estudo internacional reconhecido nesta matéria. Material e métodos – A amostra foi constituída por 84 gestantes que realizaram ressonância magnética fetal numa clínica de imagiologia médica da região Centro. A medição considerada para a avaliação do desenvolvimento fetal foi o diâmetro transversal do cerebelo. Resultados – Os resultados obtidos para o diâmetro transversal do cerebelo por ressonância magnética fetal vieram a demonstrar a ausência de diferenças médias estatisticamente significativas (p>0,05) em função do número de semanas de gestação, face aos valores teóricos aferidos no estudo de Garel. Conclusão – Com base nos resultados obtidos, para o diâmetro transversal do cerebelo podemos concluir que o parâmetro analisado é coerente com a publicação de Catherine Garel – Le développement du cerveau foetal atlas IRM et biometrie.Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)2014-06-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.25758/set.1064oai:journals.ipl.pt:article/671Saúde e Tecnologia; No. T2 (2014): Nº temático - Ressonância Magnética; e39-e42Saúde & Tecnologia; N.º T2 (2014): Nº temático - Ressonância Magnética; e39-e421646-9704reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPporhttps://journals.ipl.pt/stecnologia/article/view/671https://doi.org/10.25758/set.1064https://journals.ipl.pt/stecnologia/article/view/671/564Direitos de Autor (c) 2022 Saúde & Tecnologiainfo:eu-repo/semantics/openAccessFarinha, CristinaTavares, Óscar2022-12-20T10:59:15Zoai:journals.ipl.pt:article/671Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T10:43:40.838163Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Development and measurement of the transverse diameter of the fetal cerebellum by MRI
Desenvolvimento e mensuração do diâmetro transversal do cerebelo fetal por ressonância magnética
title Development and measurement of the transverse diameter of the fetal cerebellum by MRI
spellingShingle Development and measurement of the transverse diameter of the fetal cerebellum by MRI
Farinha, Cristina
Ressonância magnética fetal
Cerebelo
Biometria
Diâmetro transversal
Fetal magnetic resonance
Cerebellum
Biometry
Transversal diameter
title_short Development and measurement of the transverse diameter of the fetal cerebellum by MRI
title_full Development and measurement of the transverse diameter of the fetal cerebellum by MRI
title_fullStr Development and measurement of the transverse diameter of the fetal cerebellum by MRI
title_full_unstemmed Development and measurement of the transverse diameter of the fetal cerebellum by MRI
title_sort Development and measurement of the transverse diameter of the fetal cerebellum by MRI
author Farinha, Cristina
author_facet Farinha, Cristina
Tavares, Óscar
author_role author
author2 Tavares, Óscar
author2_role author
dc.contributor.author.fl_str_mv Farinha, Cristina
Tavares, Óscar
dc.subject.por.fl_str_mv Ressonância magnética fetal
Cerebelo
Biometria
Diâmetro transversal
Fetal magnetic resonance
Cerebellum
Biometry
Transversal diameter
topic Ressonância magnética fetal
Cerebelo
Biometria
Diâmetro transversal
Fetal magnetic resonance
Cerebellum
Biometry
Transversal diameter
description Fetal magnetic resonance imaging (MRI) is an effective method in the prenatal evaluation of normal brain morphology and diagnosis of diseases of the central nervous system. It is an important complement to clinical ultrasound. The cerebellum is one of the least affected structures in cases of fetal growth restriction, so it is a good index for evaluating fetal development and gestational age. Thus, biometric evaluation is essential in fetal prenatal diagnosis of brain development. Purpose – Evaluation of the transversal cerebellum diameter (the anatomical structures reference of the fetal central nervous system) and compare it with an international reference study in this regard. Material and methods – The sample consisted of 84 pregnant women who have performed magnetic resonance in a medical imaging clinic in the Centre region. The average considered for evaluating fetal development was the transversal cerebellum diameter. Results – The results for the transversal cerebellum diameter demonstrate the absence of statistically significant mean differences (p>0.05) in the number of weeks of gestation compared with theoretical values measured in the study by Garel. Conclusion – Based on the obtained results we can conclude that the parameter analyzed is consistent with the publication of Catherine Garel – Le développement du cerveau foetal atlas IRM et biometrie.
publishDate 2014
dc.date.none.fl_str_mv 2014-06-30
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.25758/set.1064
oai:journals.ipl.pt:article/671
url https://doi.org/10.25758/set.1064
identifier_str_mv oai:journals.ipl.pt:article/671
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://journals.ipl.pt/stecnologia/article/view/671
https://doi.org/10.25758/set.1064
https://journals.ipl.pt/stecnologia/article/view/671/564
dc.rights.driver.fl_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
dc.source.none.fl_str_mv Saúde e Tecnologia; No. T2 (2014): Nº temático - Ressonância Magnética; e39-e42
Saúde & Tecnologia; N.º T2 (2014): Nº temático - Ressonância Magnética; e39-e42
1646-9704
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833591166694588416