Effect of sample area in reverberant chamber measurements of sound absorption coefficients

Bibliographic Details
Main Author: António P. O. Carvalho
Publication Date: 2016
Other Authors: Mário R. M. Sousa
Format: Book
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10216/85486
Summary: To evaluate the influence of the sample size on the experiments in a reverberant chamber to determine the sound absorption coefficient, the reasonable minimum sample area needed was analyzed, considering that the quantity of material is important for those who want to test it. Samples from 1 to 12 m2 (by increments of 1 m2 ) were used. The influence of the sample position on the room's floor has also been tested for a 10 m2 sample arranged on the center of the reverberating chamber and scattered around the room.
id RCAP_2bb9abb1bd486ebb22b19e33c508c6a0
oai_identifier_str oai:repositorio-aberto.up.pt:10216/85486
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Effect of sample area in reverberant chamber measurements of sound absorption coefficientsEngenharia civil, Acústica, Engenharia civilCivil engineering, Acoustics, Civil engineeringTo evaluate the influence of the sample size on the experiments in a reverberant chamber to determine the sound absorption coefficient, the reasonable minimum sample area needed was analyzed, considering that the quantity of material is important for those who want to test it. Samples from 1 to 12 m2 (by increments of 1 m2 ) were used. The influence of the sample position on the room's floor has also been tested for a 10 m2 sample arranged on the center of the reverberating chamber and scattered around the room.2016-09-062016-09-06T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/85486engAntónio P. O. CarvalhoMário R. M. Sousainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:26:23Zoai:repositorio-aberto.up.pt:10216/85486Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:18:59.548157Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Effect of sample area in reverberant chamber measurements of sound absorption coefficients
title Effect of sample area in reverberant chamber measurements of sound absorption coefficients
spellingShingle Effect of sample area in reverberant chamber measurements of sound absorption coefficients
António P. O. Carvalho
Engenharia civil, Acústica, Engenharia civil
Civil engineering, Acoustics, Civil engineering
title_short Effect of sample area in reverberant chamber measurements of sound absorption coefficients
title_full Effect of sample area in reverberant chamber measurements of sound absorption coefficients
title_fullStr Effect of sample area in reverberant chamber measurements of sound absorption coefficients
title_full_unstemmed Effect of sample area in reverberant chamber measurements of sound absorption coefficients
title_sort Effect of sample area in reverberant chamber measurements of sound absorption coefficients
author António P. O. Carvalho
author_facet António P. O. Carvalho
Mário R. M. Sousa
author_role author
author2 Mário R. M. Sousa
author2_role author
dc.contributor.author.fl_str_mv António P. O. Carvalho
Mário R. M. Sousa
dc.subject.por.fl_str_mv Engenharia civil, Acústica, Engenharia civil
Civil engineering, Acoustics, Civil engineering
topic Engenharia civil, Acústica, Engenharia civil
Civil engineering, Acoustics, Civil engineering
description To evaluate the influence of the sample size on the experiments in a reverberant chamber to determine the sound absorption coefficient, the reasonable minimum sample area needed was analyzed, considering that the quantity of material is important for those who want to test it. Samples from 1 to 12 m2 (by increments of 1 m2 ) were used. The influence of the sample position on the room's floor has also been tested for a 10 m2 sample arranged on the center of the reverberating chamber and scattered around the room.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-06
2016-09-06T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/book
format book
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/85486
url https://hdl.handle.net/10216/85486
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600101261508608