Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study

Detalhes bibliográficos
Autor(a) principal: Castro,Pedro Almiro e
Data de Publicação: 2023
Outros Autores: Correia,Ana Luísa, Mira,Filipe, Cerqueira,Sofia, Oliveira,Nuno Afonso, Maia,Pedro, Alves,Rui
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021
Resumo: ABSTRACT Introduction: Sleep disorders affect up to 70% of peritoneal dialysis (PD) patients and appear to have significant negative effects on their quality of life (QoL). We compared life and sleep quality between patients on automated PD (APD) and continuous ambulatory PD (CAPD). Material and Methods: Cross-sectional study in chronic PD patients followed in our Dialysis Unit in February 2022. We evaluated sleep quality with the Pittsburgh Sleep Quality Index (PSQI) and the Epworth Sleepiness Scale (ESS) and QoL with EUROHIS-QOL-8. Results: Fifty-two patients, mostly men (65.4%, n=32), with a mean age of 52.7±14.2 years and PD vintage of 24.3±17.1 months. Our sample had similar distribution between APD and CAPD; we found no difference between groups regarding demographic data, PD-related quality parameters or prevalence of previous sleep disturbances. Mean QoL index was 69.9%±9.3% and similar between APD and CAPD patients; EUROHIS-QOL-8 negatively correlated with the scores on ESS (p=0.004) and PSQI (p=0.011). Regarding sleep quality, the mean ESS was 8.8±4.2 and PSQI was 7.6±3.6. APD patients had similar scores on ESS, but higher prevalence of severe daytime sleepiness (ESS≥18) (p=0.04) and higher scores on PSQI (p=0.002). Within the PSQI, sleep’ latency (p=0.003), duration (p=0.002) and efficiency (p=0.013) were the most affected parameters. Higher PSQI scores also correlated with worse blood pressure control; a cut-off value for PSQI of 6 was found to increase the risk of uncontrolled hypertension. Conclusion: In our series, APD patients had worse global sleep quality (PSQI) when compared to ACPD patients. This difference was mainly due to worse sleep latency, duration and efficiency. The assessment of the quality of life showed no difference between groups, however there was a clear link between quality of life and sleep quality.
id RCAP_283f3b0fa3983e7f64b46cfd59a1eb4c
oai_identifier_str oai:scielo:S0872-01692023000100021
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative StudyPeritoneal DialysisPeritoneal Dialysis, Continuous AmbulatoryQuality of LifeSleep QualityABSTRACT Introduction: Sleep disorders affect up to 70% of peritoneal dialysis (PD) patients and appear to have significant negative effects on their quality of life (QoL). We compared life and sleep quality between patients on automated PD (APD) and continuous ambulatory PD (CAPD). Material and Methods: Cross-sectional study in chronic PD patients followed in our Dialysis Unit in February 2022. We evaluated sleep quality with the Pittsburgh Sleep Quality Index (PSQI) and the Epworth Sleepiness Scale (ESS) and QoL with EUROHIS-QOL-8. Results: Fifty-two patients, mostly men (65.4%, n=32), with a mean age of 52.7±14.2 years and PD vintage of 24.3±17.1 months. Our sample had similar distribution between APD and CAPD; we found no difference between groups regarding demographic data, PD-related quality parameters or prevalence of previous sleep disturbances. Mean QoL index was 69.9%±9.3% and similar between APD and CAPD patients; EUROHIS-QOL-8 negatively correlated with the scores on ESS (p=0.004) and PSQI (p=0.011). Regarding sleep quality, the mean ESS was 8.8±4.2 and PSQI was 7.6±3.6. APD patients had similar scores on ESS, but higher prevalence of severe daytime sleepiness (ESS≥18) (p=0.04) and higher scores on PSQI (p=0.002). Within the PSQI, sleep’ latency (p=0.003), duration (p=0.002) and efficiency (p=0.013) were the most affected parameters. Higher PSQI scores also correlated with worse blood pressure control; a cut-off value for PSQI of 6 was found to increase the risk of uncontrolled hypertension. Conclusion: In our series, APD patients had worse global sleep quality (PSQI) when compared to ACPD patients. This difference was mainly due to worse sleep latency, duration and efficiency. The assessment of the quality of life showed no difference between groups, however there was a clear link between quality of life and sleep quality.Sociedade Portuguesa de Nefrologia2023-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021Portuguese Journal of Nephrology & Hypertension v.37 n.1 2023reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021Castro,Pedro Almiro eCorreia,Ana LuísaMira,FilipeCerqueira,SofiaOliveira,Nuno AfonsoMaia,PedroAlves,Ruiinfo:eu-repo/semantics/openAccess2024-02-06T17:05:16Zoai:scielo:S0872-01692023000100021Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:54:41.920088Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
title Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
spellingShingle Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
Castro,Pedro Almiro e
Peritoneal Dialysis
Peritoneal Dialysis, Continuous Ambulatory
Quality of Life
Sleep Quality
title_short Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
title_full Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
title_fullStr Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
title_full_unstemmed Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
title_sort Life and Sleep Quality amongst Peritoneal Dialysis Patients: A Comparative Study
author Castro,Pedro Almiro e
author_facet Castro,Pedro Almiro e
Correia,Ana Luísa
Mira,Filipe
Cerqueira,Sofia
Oliveira,Nuno Afonso
Maia,Pedro
Alves,Rui
author_role author
author2 Correia,Ana Luísa
Mira,Filipe
Cerqueira,Sofia
Oliveira,Nuno Afonso
Maia,Pedro
Alves,Rui
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Castro,Pedro Almiro e
Correia,Ana Luísa
Mira,Filipe
Cerqueira,Sofia
Oliveira,Nuno Afonso
Maia,Pedro
Alves,Rui
dc.subject.por.fl_str_mv Peritoneal Dialysis
Peritoneal Dialysis, Continuous Ambulatory
Quality of Life
Sleep Quality
topic Peritoneal Dialysis
Peritoneal Dialysis, Continuous Ambulatory
Quality of Life
Sleep Quality
description ABSTRACT Introduction: Sleep disorders affect up to 70% of peritoneal dialysis (PD) patients and appear to have significant negative effects on their quality of life (QoL). We compared life and sleep quality between patients on automated PD (APD) and continuous ambulatory PD (CAPD). Material and Methods: Cross-sectional study in chronic PD patients followed in our Dialysis Unit in February 2022. We evaluated sleep quality with the Pittsburgh Sleep Quality Index (PSQI) and the Epworth Sleepiness Scale (ESS) and QoL with EUROHIS-QOL-8. Results: Fifty-two patients, mostly men (65.4%, n=32), with a mean age of 52.7±14.2 years and PD vintage of 24.3±17.1 months. Our sample had similar distribution between APD and CAPD; we found no difference between groups regarding demographic data, PD-related quality parameters or prevalence of previous sleep disturbances. Mean QoL index was 69.9%±9.3% and similar between APD and CAPD patients; EUROHIS-QOL-8 negatively correlated with the scores on ESS (p=0.004) and PSQI (p=0.011). Regarding sleep quality, the mean ESS was 8.8±4.2 and PSQI was 7.6±3.6. APD patients had similar scores on ESS, but higher prevalence of severe daytime sleepiness (ESS≥18) (p=0.04) and higher scores on PSQI (p=0.002). Within the PSQI, sleep’ latency (p=0.003), duration (p=0.002) and efficiency (p=0.013) were the most affected parameters. Higher PSQI scores also correlated with worse blood pressure control; a cut-off value for PSQI of 6 was found to increase the risk of uncontrolled hypertension. Conclusion: In our series, APD patients had worse global sleep quality (PSQI) when compared to ACPD patients. This difference was mainly due to worse sleep latency, duration and efficiency. The assessment of the quality of life showed no difference between groups, however there was a clear link between quality of life and sleep quality.
publishDate 2023
dc.date.none.fl_str_mv 2023-03-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-01692023000100021
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Nefrologia
publisher.none.fl_str_mv Sociedade Portuguesa de Nefrologia
dc.source.none.fl_str_mv Portuguese Journal of Nephrology & Hypertension v.37 n.1 2023
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833593242818445312