Summary: | The application of closed refrigerated multideck display cases (CRDC) and electronic fans is slowly increasing in Brazilians supermarkets, following the international trend. In order to obtain energy savings, this paper reports the results of experimental tests performed in a CRDC according to ISO 23953 to evaluate the influence of (1) environmental conditions, (2) gaps between doors and (3) fans type on the overall performance of a display case. Experimental laboratory tests were performed on two different conditions of temperature and relative humidity of the ambient air (Tamb=25°C; amb=60% and Tamb=27°C; amb=70%), with electromagnetic and electronic fans, and with and without gaps between doors. The analysis and discussion of experimental results include the comparison of compressor energy consumption, total heat load, total condensed water collected on defrost periods and air and product temperatures. The experimental data analysis provides valuable information to set the operative parameters of the CRDC taking into account usual in-store conditions in Brazil. |
id |
RCAP_263e54b340b7ecb13358eee69d395ed2 |
---|---|
oai_identifier_str |
oai:ubibliorum.ubi.pt:10400.6/7370 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Relevant parameters on the energy efficiency of closed refrigerated multideck display casesClosed refrigerated display casesEnergy efficiencyCommercial refrigerationSupermarketEnvironmental conditionFansDoorsThe application of closed refrigerated multideck display cases (CRDC) and electronic fans is slowly increasing in Brazilians supermarkets, following the international trend. In order to obtain energy savings, this paper reports the results of experimental tests performed in a CRDC according to ISO 23953 to evaluate the influence of (1) environmental conditions, (2) gaps between doors and (3) fans type on the overall performance of a display case. Experimental laboratory tests were performed on two different conditions of temperature and relative humidity of the ambient air (Tamb=25°C; amb=60% and Tamb=27°C; amb=70%), with electromagnetic and electronic fans, and with and without gaps between doors. The analysis and discussion of experimental results include the comparison of compressor energy consumption, total heat load, total condensed water collected on defrost periods and air and product temperatures. The experimental data analysis provides valuable information to set the operative parameters of the CRDC taking into account usual in-store conditions in Brazil.2nd International Conference on Energy Production and Management in the 21st Century (Energy Quest 2016)uBibliorumHeidinger, Gustavo GaldiNascimento, Samuel Mariano doGaspar, Pedro DinisSilva, Pedro Dinho da2019-10-24T13:25:54Z20162016-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/7370enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-11T15:08:51Zoai:ubibliorum.ubi.pt:10400.6/7370Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T01:23:53.320111Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
title |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
spellingShingle |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases Heidinger, Gustavo Galdi Closed refrigerated display cases Energy efficiency Commercial refrigeration Supermarket Environmental condition Fans Doors |
title_short |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
title_full |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
title_fullStr |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
title_full_unstemmed |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
title_sort |
Relevant parameters on the energy efficiency of closed refrigerated multideck display cases |
author |
Heidinger, Gustavo Galdi |
author_facet |
Heidinger, Gustavo Galdi Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
author_role |
author |
author2 |
Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
uBibliorum |
dc.contributor.author.fl_str_mv |
Heidinger, Gustavo Galdi Nascimento, Samuel Mariano do Gaspar, Pedro Dinis Silva, Pedro Dinho da |
dc.subject.por.fl_str_mv |
Closed refrigerated display cases Energy efficiency Commercial refrigeration Supermarket Environmental condition Fans Doors |
topic |
Closed refrigerated display cases Energy efficiency Commercial refrigeration Supermarket Environmental condition Fans Doors |
description |
The application of closed refrigerated multideck display cases (CRDC) and electronic fans is slowly increasing in Brazilians supermarkets, following the international trend. In order to obtain energy savings, this paper reports the results of experimental tests performed in a CRDC according to ISO 23953 to evaluate the influence of (1) environmental conditions, (2) gaps between doors and (3) fans type on the overall performance of a display case. Experimental laboratory tests were performed on two different conditions of temperature and relative humidity of the ambient air (Tamb=25°C; amb=60% and Tamb=27°C; amb=70%), with electromagnetic and electronic fans, and with and without gaps between doors. The analysis and discussion of experimental results include the comparison of compressor energy consumption, total heat load, total condensed water collected on defrost periods and air and product temperatures. The experimental data analysis provides valuable information to set the operative parameters of the CRDC taking into account usual in-store conditions in Brazil. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 2016-01-01T00:00:00Z 2019-10-24T13:25:54Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.6/7370 |
url |
http://hdl.handle.net/10400.6/7370 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
2nd International Conference on Energy Production and Management in the 21st Century (Energy Quest 2016) |
publisher.none.fl_str_mv |
2nd International Conference on Energy Production and Management in the 21st Century (Energy Quest 2016) |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833600961088585728 |