Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer

Bibliographic Details
Main Author: Tanta, Mohamed
Publication Date: 2017
Other Authors: Afonso, José A., Martins, Antonio P., Carvalho, Adriano S., Afonso, João L.
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/1822/47920
Summary: This paper presents a rail power conditioner (RPC) system based on an indirect AC/DC/AC modular multilevel converter (MMC) where a V/V power transformer is used to feed the main catenary line and the locomotives. The proposed control strategy for this system has been introduced to guarantee a good compensating performance of negative sequence currents (NSCs) and harmonics on the public grid side. This control strategy has also the ability to achieve balanced and equal voltage between the MMC’s submodules (SMs) capacitors. Simulation results for this RPC based on an indirect MMC are presented in this paper to show the main advantages of using this topology. The results show how the proposed system is able to compensate NSCs and harmonics on the public grid side when the V/V power transformer feeds two unequal load sections.
id RCAP_247999f2d0066e79b59d9f87a21e7caf
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/47920
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformerModular multilevel converter (MMC)Negative sequence currents (NSCs)Rail power conditioner (RPC)Submodules (SMs)Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e InformáticaThis paper presents a rail power conditioner (RPC) system based on an indirect AC/DC/AC modular multilevel converter (MMC) where a V/V power transformer is used to feed the main catenary line and the locomotives. The proposed control strategy for this system has been introduced to guarantee a good compensating performance of negative sequence currents (NSCs) and harmonics on the public grid side. This control strategy has also the ability to achieve balanced and equal voltage between the MMC’s submodules (SMs) capacitors. Simulation results for this RPC based on an indirect MMC are presented in this paper to show the main advantages of using this topology. The results show how the proposed system is able to compensate NSCs and harmonics on the public grid side when the V/V power transformer feeds two unequal load sections.Fundação para a Ciência e Tecnologia (FCT)info:eu-repo/semantics/publishedVersionNewswood Limited PublisherUniversidade do MinhoTanta, MohamedAfonso, José A.Martins, Antonio P.Carvalho, Adriano S.Afonso, João L.2017-07-052017-07-05T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/47920eng978-988-14047-4-92078-09582078-0966http://www.iaeng.org/publication/WCE2017/WCE2017_pp289-294.pdfinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T07:40:15Zoai:repositorium.sdum.uminho.pt:1822/47920Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:35:32.863764Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
title Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
spellingShingle Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
Tanta, Mohamed
Modular multilevel converter (MMC)
Negative sequence currents (NSCs)
Rail power conditioner (RPC)
Submodules (SMs)
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
title_short Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
title_full Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
title_fullStr Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
title_full_unstemmed Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
title_sort Rail power conditioner based on indirect AC/DC/AC modular multilevel converter using a three-phase V/V power transformer
author Tanta, Mohamed
author_facet Tanta, Mohamed
Afonso, José A.
Martins, Antonio P.
Carvalho, Adriano S.
Afonso, João L.
author_role author
author2 Afonso, José A.
Martins, Antonio P.
Carvalho, Adriano S.
Afonso, João L.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Tanta, Mohamed
Afonso, José A.
Martins, Antonio P.
Carvalho, Adriano S.
Afonso, João L.
dc.subject.por.fl_str_mv Modular multilevel converter (MMC)
Negative sequence currents (NSCs)
Rail power conditioner (RPC)
Submodules (SMs)
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
topic Modular multilevel converter (MMC)
Negative sequence currents (NSCs)
Rail power conditioner (RPC)
Submodules (SMs)
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
description This paper presents a rail power conditioner (RPC) system based on an indirect AC/DC/AC modular multilevel converter (MMC) where a V/V power transformer is used to feed the main catenary line and the locomotives. The proposed control strategy for this system has been introduced to guarantee a good compensating performance of negative sequence currents (NSCs) and harmonics on the public grid side. This control strategy has also the ability to achieve balanced and equal voltage between the MMC’s submodules (SMs) capacitors. Simulation results for this RPC based on an indirect MMC are presented in this paper to show the main advantages of using this topology. The results show how the proposed system is able to compensate NSCs and harmonics on the public grid side when the V/V power transformer feeds two unequal load sections.
publishDate 2017
dc.date.none.fl_str_mv 2017-07-05
2017-07-05T00:00:00Z
dc.type.driver.fl_str_mv conference paper
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/47920
url http://hdl.handle.net/1822/47920
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 978-988-14047-4-9
2078-0958
2078-0966
http://www.iaeng.org/publication/WCE2017/WCE2017_pp289-294.pdf
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Newswood Limited Publisher
publisher.none.fl_str_mv Newswood Limited Publisher
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833596041372368896