Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance

Bibliographic Details
Main Author: Simoes, T
Publication Date: 2011
Other Authors: Julio, C, Cordeiro, A, Cohen, A, Silva, A, Blickstein, I
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.17/2614
Summary: OBJECTIVES: We assessed the accuracy of predicting severe twin birth weight discordance (>25%) using the estimated fetal weights (EFW) and abdominal circumference (AC) ratio. METHOD: A cohort of twin gestations underwent ultrasound examinations within two weeks from birth. We focused on the accuracy of EFW and on the diagnosis of severe birth weight discordance by the difference in EFWs and the AC ratio. RESULTS: The 661 eligible twin pairs included 51 (7.7%) severely discordant pairs. The accuracy of an EFW to predict the actual birth weight was quite poor, with an acceptable specificity (96.4%), but low sensitivity (28.6-40.5%), to detect severely discordant pairs, whereas an AC ratio of 1.3 detected these discordant pairs with sensitivity and specificity of 97.3-100% and 99.6-99.7%, respectively. CONCLUSION: By comparing EFWs, 59.5-71.4% of discordant pairs >25% are missed, whereas an AC ratio >1.3 would identify almost all cases.
id RCAP_1c96576ea753c7d1acc1d21a9ceda8f8
oai_identifier_str oai:repositorio.chlc.pt:10400.17/2614
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight DiscordanceMAC MED MAFBirth WeightFetal Diseases/diagnostic imagingFetal WeightInfant, NewbornInfant, Small for Gestational AgePredictive Value of TestsPregnancyTwins/physiologyUltrasonography, PrenatalWaist CircumferenceOBJECTIVES: We assessed the accuracy of predicting severe twin birth weight discordance (>25%) using the estimated fetal weights (EFW) and abdominal circumference (AC) ratio. METHOD: A cohort of twin gestations underwent ultrasound examinations within two weeks from birth. We focused on the accuracy of EFW and on the diagnosis of severe birth weight discordance by the difference in EFWs and the AC ratio. RESULTS: The 661 eligible twin pairs included 51 (7.7%) severely discordant pairs. The accuracy of an EFW to predict the actual birth weight was quite poor, with an acceptable specificity (96.4%), but low sensitivity (28.6-40.5%), to detect severely discordant pairs, whereas an AC ratio of 1.3 detected these discordant pairs with sensitivity and specificity of 97.3-100% and 99.6-99.7%, respectively. CONCLUSION: By comparing EFWs, 59.5-71.4% of discordant pairs >25% are missed, whereas an AC ratio >1.3 would identify almost all cases.De GruyterRepositório da Unidade Local de Saúde São JoséSimoes, TJulio, CCordeiro, ACohen, ASilva, ABlickstein, I2017-01-11T15:44:15Z20112011-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/2614eng10.1515/jpm.2010.124info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-06T16:52:24Zoai:repositorio.chlc.pt:10400.17/2614Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:23:17.671688Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
title Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
spellingShingle Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
Simoes, T
MAC MED MAF
Birth Weight
Fetal Diseases/diagnostic imaging
Fetal Weight
Infant, Newborn
Infant, Small for Gestational Age
Predictive Value of Tests
Pregnancy
Twins/physiology
Ultrasonography, Prenatal
Waist Circumference
title_short Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
title_full Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
title_fullStr Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
title_full_unstemmed Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
title_sort Abdominal Circumference Ratio for the Diagnosis of Intertwin Birth Weight Discordance
author Simoes, T
author_facet Simoes, T
Julio, C
Cordeiro, A
Cohen, A
Silva, A
Blickstein, I
author_role author
author2 Julio, C
Cordeiro, A
Cohen, A
Silva, A
Blickstein, I
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório da Unidade Local de Saúde São José
dc.contributor.author.fl_str_mv Simoes, T
Julio, C
Cordeiro, A
Cohen, A
Silva, A
Blickstein, I
dc.subject.por.fl_str_mv MAC MED MAF
Birth Weight
Fetal Diseases/diagnostic imaging
Fetal Weight
Infant, Newborn
Infant, Small for Gestational Age
Predictive Value of Tests
Pregnancy
Twins/physiology
Ultrasonography, Prenatal
Waist Circumference
topic MAC MED MAF
Birth Weight
Fetal Diseases/diagnostic imaging
Fetal Weight
Infant, Newborn
Infant, Small for Gestational Age
Predictive Value of Tests
Pregnancy
Twins/physiology
Ultrasonography, Prenatal
Waist Circumference
description OBJECTIVES: We assessed the accuracy of predicting severe twin birth weight discordance (>25%) using the estimated fetal weights (EFW) and abdominal circumference (AC) ratio. METHOD: A cohort of twin gestations underwent ultrasound examinations within two weeks from birth. We focused on the accuracy of EFW and on the diagnosis of severe birth weight discordance by the difference in EFWs and the AC ratio. RESULTS: The 661 eligible twin pairs included 51 (7.7%) severely discordant pairs. The accuracy of an EFW to predict the actual birth weight was quite poor, with an acceptable specificity (96.4%), but low sensitivity (28.6-40.5%), to detect severely discordant pairs, whereas an AC ratio of 1.3 detected these discordant pairs with sensitivity and specificity of 97.3-100% and 99.6-99.7%, respectively. CONCLUSION: By comparing EFWs, 59.5-71.4% of discordant pairs >25% are missed, whereas an AC ratio >1.3 would identify almost all cases.
publishDate 2011
dc.date.none.fl_str_mv 2011
2011-01-01T00:00:00Z
2017-01-11T15:44:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/2614
url http://hdl.handle.net/10400.17/2614
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1515/jpm.2010.124
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv De Gruyter
publisher.none.fl_str_mv De Gruyter
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600514727608320