Indoor air quality in community health centers: a preliminary study
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2013 |
| Outros Autores: | , , |
| Idioma: | eng |
| Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Texto Completo: | http://hdl.handle.net/10400.22/18829 |
Resumo: | Indoor air quality (IAQ) in healthcare facilities is of great concern for both patients and staff. The aim of this study was to evaluate the IAQ in Community Health Centers. Total aerobic count and fungal load were assessed using a microbiological air sampler. The determination of the other parameters was per formed using real-time equipments. The average concentrations ranged between 161 CFU/m3 and 1423 CFU/m3 for fungi and between 147 CFU/m3 and 999 CFU/m3 for total aerobic count. Only three waiting rooms exceeded the concentration reference value for carbon dioxide. The concentration of particulate matter and carbon monoxide were above the limit value. In general, physical parameters are outside the comfort zones. These results demonstrate the need for on-going efforts to ensure adequate ventilation in Community Health Centers to maintain an acceptable IAQ. Therefore, it is essential to accomplish a long-term surveil lance of IAQ in this type of buildings |
| id |
RCAP_1972872bf355394a1c43ae59dfd77fa5 |
|---|---|
| oai_identifier_str |
oai:recipp.ipp.pt:10400.22/18829 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Indoor air quality in community health centers: a preliminary studyIndoor air qualityCommunity health centersEnvironmental parametersVentilationIndoor air quality (IAQ) in healthcare facilities is of great concern for both patients and staff. The aim of this study was to evaluate the IAQ in Community Health Centers. Total aerobic count and fungal load were assessed using a microbiological air sampler. The determination of the other parameters was per formed using real-time equipments. The average concentrations ranged between 161 CFU/m3 and 1423 CFU/m3 for fungi and between 147 CFU/m3 and 999 CFU/m3 for total aerobic count. Only three waiting rooms exceeded the concentration reference value for carbon dioxide. The concentration of particulate matter and carbon monoxide were above the limit value. In general, physical parameters are outside the comfort zones. These results demonstrate the need for on-going efforts to ensure adequate ventilation in Community Health Centers to maintain an acceptable IAQ. Therefore, it is essential to accomplish a long-term surveil lance of IAQ in this type of buildingsSociedade Portuguesa de Segurança e Higiene Ocupacionais (SPOSHO)REPOSITÓRIO P.PORTOSantos, L.Santos, J.Rebelo, A.Vieira Da Silva, Manuela2021-11-08T16:31:41Z20132013-01-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.22/18829eng978-989-98203-0-2info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-07T10:06:54Zoai:recipp.ipp.pt:10400.22/18829Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:33:26.307522Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Indoor air quality in community health centers: a preliminary study |
| title |
Indoor air quality in community health centers: a preliminary study |
| spellingShingle |
Indoor air quality in community health centers: a preliminary study Santos, L. Indoor air quality Community health centers Environmental parameters Ventilation |
| title_short |
Indoor air quality in community health centers: a preliminary study |
| title_full |
Indoor air quality in community health centers: a preliminary study |
| title_fullStr |
Indoor air quality in community health centers: a preliminary study |
| title_full_unstemmed |
Indoor air quality in community health centers: a preliminary study |
| title_sort |
Indoor air quality in community health centers: a preliminary study |
| author |
Santos, L. |
| author_facet |
Santos, L. Santos, J. Rebelo, A. Vieira Da Silva, Manuela |
| author_role |
author |
| author2 |
Santos, J. Rebelo, A. Vieira Da Silva, Manuela |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
REPOSITÓRIO P.PORTO |
| dc.contributor.author.fl_str_mv |
Santos, L. Santos, J. Rebelo, A. Vieira Da Silva, Manuela |
| dc.subject.por.fl_str_mv |
Indoor air quality Community health centers Environmental parameters Ventilation |
| topic |
Indoor air quality Community health centers Environmental parameters Ventilation |
| description |
Indoor air quality (IAQ) in healthcare facilities is of great concern for both patients and staff. The aim of this study was to evaluate the IAQ in Community Health Centers. Total aerobic count and fungal load were assessed using a microbiological air sampler. The determination of the other parameters was per formed using real-time equipments. The average concentrations ranged between 161 CFU/m3 and 1423 CFU/m3 for fungi and between 147 CFU/m3 and 999 CFU/m3 for total aerobic count. Only three waiting rooms exceeded the concentration reference value for carbon dioxide. The concentration of particulate matter and carbon monoxide were above the limit value. In general, physical parameters are outside the comfort zones. These results demonstrate the need for on-going efforts to ensure adequate ventilation in Community Health Centers to maintain an acceptable IAQ. Therefore, it is essential to accomplish a long-term surveil lance of IAQ in this type of buildings |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 2013-01-01T00:00:00Z 2021-11-08T16:31:41Z |
| dc.type.driver.fl_str_mv |
conference object |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/18829 |
| url |
http://hdl.handle.net/10400.22/18829 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
978-989-98203-0-2 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Segurança e Higiene Ocupacionais (SPOSHO) |
| publisher.none.fl_str_mv |
Sociedade Portuguesa de Segurança e Higiene Ocupacionais (SPOSHO) |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833600591447719937 |