Export Ready — 

Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report

Bibliographic Details
Main Author: Figueiredo, Pedro N.
Publication Date: 2011
Other Authors: Figueiredo, Isabel N., Prasath, Surya, Tsai, Richard
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10316/15542
https://doi.org/10.1155/2011/182435
Summary: Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed bymeans of a P-value, defined by geometrical features. Results. Seventeen PillCamCOLON2 capsule videos are included, containing frames with polyps, flat lesions, diverticula, bubbles, and trash liquids. Polyps larger than 1 cmexpress a P-value higher than 2000, and 80% of the polyps show a P-value higher than 500. Diverticula, bubbles, trash liquids, and flat lesions were correctly interpreted by the algorithmas nonprotruding images. Conclusions. These preliminary results suggest that the proposed geometrybased polyp detection scheme works well, not only by allowing the detection of polyps but also by differentiating them from nonprotruding images found in the films.
id RCAP_1605082dc4d3a6181f09e29f27449a96
oai_identifier_str oai:estudogeral.uc.pt:10316/15542
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility ReportBackground. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed bymeans of a P-value, defined by geometrical features. Results. Seventeen PillCamCOLON2 capsule videos are included, containing frames with polyps, flat lesions, diverticula, bubbles, and trash liquids. Polyps larger than 1 cmexpress a P-value higher than 2000, and 80% of the polyps show a P-value higher than 500. Diverticula, bubbles, trash liquids, and flat lesions were correctly interpreted by the algorithmas nonprotruding images. Conclusions. These preliminary results suggest that the proposed geometrybased polyp detection scheme works well, not only by allowing the detection of polyps but also by differentiating them from nonprotruding images found in the films.Hindawi Publishing Corporation2011info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://hdl.handle.net/10316/15542https://hdl.handle.net/10316/15542https://doi.org/10.1155/2011/182435engFIGUEIREDO, Pedro N. [et al.] - Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report. "Diagnostic and Therapeutic Endoscopy". ISSN 1070-3608. Vol. 2011 (2011) 7 p.1070-3608Figueiredo, Pedro N.Figueiredo, Isabel N.Prasath, SuryaTsai, Richardinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2020-05-29T09:42:07Zoai:estudogeral.uc.pt:10316/15542Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T04:54:54.787171Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
spellingShingle Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
Figueiredo, Pedro N.
title_short Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_full Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_fullStr Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_full_unstemmed Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
title_sort Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report
author Figueiredo, Pedro N.
author_facet Figueiredo, Pedro N.
Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
author_role author
author2 Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
author2_role author
author
author
dc.contributor.author.fl_str_mv Figueiredo, Pedro N.
Figueiredo, Isabel N.
Prasath, Surya
Tsai, Richard
description Background. The aim of this work is to present an automatic colorectal polyp detection scheme for capsule endoscopy. Methods. PillCam COLON2 capsule-based images and videos were used in our study. The database consists of full exam videos from five patients. The algorithm is based on the assumption that the polyps show up as a protrusion in the captured images and is expressed bymeans of a P-value, defined by geometrical features. Results. Seventeen PillCamCOLON2 capsule videos are included, containing frames with polyps, flat lesions, diverticula, bubbles, and trash liquids. Polyps larger than 1 cmexpress a P-value higher than 2000, and 80% of the polyps show a P-value higher than 500. Diverticula, bubbles, trash liquids, and flat lesions were correctly interpreted by the algorithmas nonprotruding images. Conclusions. These preliminary results suggest that the proposed geometrybased polyp detection scheme works well, not only by allowing the detection of polyps but also by differentiating them from nonprotruding images found in the films.
publishDate 2011
dc.date.none.fl_str_mv 2011
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10316/15542
https://hdl.handle.net/10316/15542
https://doi.org/10.1155/2011/182435
url https://hdl.handle.net/10316/15542
https://doi.org/10.1155/2011/182435
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv FIGUEIREDO, Pedro N. [et al.] - Automatic Polyp Detection in Pillcam Colon 2 Capsule Images and Videos: Preliminary Feasibility Report. "Diagnostic and Therapeutic Endoscopy". ISSN 1070-3608. Vol. 2011 (2011) 7 p.
1070-3608
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Hindawi Publishing Corporation
publisher.none.fl_str_mv Hindawi Publishing Corporation
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833602191046213632