Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers
| Main Author: | |
|---|---|
| Publication Date: | 2022 |
| Other Authors: | , , , |
| Language: | eng |
| Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Download full: | http://hdl.handle.net/10400.9/3952 |
Summary: | ABSTRACT: Hydrogenated amorphous carbon (a-C:H) top layer was deposited onto 316L medical grade stainless steel by reactive magnetron sputtering with two types of interlayers, based on Cr and Ti. The goal was to evaluate the effect of the adhesion-promoting layers on the overall coating/substrate system. After the immersion test in acidic artificial saliva, no surface signs of corrosion were detected. However, the Cr-based interlayer enhanced the metallic ions release, whereas the Ti-based one seems to improve the corrosion resistance. Electrochemical Impedance Spectroscopy was also used to evaluate galvanic corrosion evolution at the adhesion interfaces. |
| id |
RCAP_15c52eccd1772d9ad00a268cf402fc6e |
|---|---|
| oai_identifier_str |
oai:null:10400.9/3952 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layersDLC coatingsMetal releaseImpedance spectroscopyOrthodonticsABSTRACT: Hydrogenated amorphous carbon (a-C:H) top layer was deposited onto 316L medical grade stainless steel by reactive magnetron sputtering with two types of interlayers, based on Cr and Ti. The goal was to evaluate the effect of the adhesion-promoting layers on the overall coating/substrate system. After the immersion test in acidic artificial saliva, no surface signs of corrosion were detected. However, the Cr-based interlayer enhanced the metallic ions release, whereas the Ti-based one seems to improve the corrosion resistance. Electrochemical Impedance Spectroscopy was also used to evaluate galvanic corrosion evolution at the adhesion interfaces.LNEG - Laboratório Nacional de Energia e GeologiaRepositório do LNEGFrois, AntónioFaia, PedroSantos, LuisSantos, AnaLouro, C.2022-11-21T16:45:42Z2022-112022-11-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10400.9/3952eng10.34637/hqsz-sd77info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-10T11:32:32Zoai:null:10400.9/3952Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T01:14:30.791289Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| title |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| spellingShingle |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers Frois, António DLC coatings Metal release Impedance spectroscopy Orthodontics |
| title_short |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| title_full |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| title_fullStr |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| title_full_unstemmed |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| title_sort |
Corrosion behaviour in artificial saliva of medical grade SS316L sputter-coated with DLC films: the effect of adhesion layers |
| author |
Frois, António |
| author_facet |
Frois, António Faia, Pedro Santos, Luis Santos, Ana Louro, C. |
| author_role |
author |
| author2 |
Faia, Pedro Santos, Luis Santos, Ana Louro, C. |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
Repositório do LNEG |
| dc.contributor.author.fl_str_mv |
Frois, António Faia, Pedro Santos, Luis Santos, Ana Louro, C. |
| dc.subject.por.fl_str_mv |
DLC coatings Metal release Impedance spectroscopy Orthodontics |
| topic |
DLC coatings Metal release Impedance spectroscopy Orthodontics |
| description |
ABSTRACT: Hydrogenated amorphous carbon (a-C:H) top layer was deposited onto 316L medical grade stainless steel by reactive magnetron sputtering with two types of interlayers, based on Cr and Ti. The goal was to evaluate the effect of the adhesion-promoting layers on the overall coating/substrate system. After the immersion test in acidic artificial saliva, no surface signs of corrosion were detected. However, the Cr-based interlayer enhanced the metallic ions release, whereas the Ti-based one seems to improve the corrosion resistance. Electrochemical Impedance Spectroscopy was also used to evaluate galvanic corrosion evolution at the adhesion interfaces. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022-11-21T16:45:42Z 2022-11 2022-11-01T00:00:00Z |
| dc.type.driver.fl_str_mv |
conference object |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.9/3952 |
| url |
http://hdl.handle.net/10400.9/3952 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
10.34637/hqsz-sd77 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
LNEG - Laboratório Nacional de Energia e Geologia |
| publisher.none.fl_str_mv |
LNEG - Laboratório Nacional de Energia e Geologia |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833600888819679232 |