Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , , |
Idioma: | eng |
Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Texto Completo: | http://hdl.handle.net/10198/1575 |
Resumo: | Flanking transmission in building structures can be estimated using the Intensity technique according to the method described in the standard EN 15186-2 Annex C. This can also be done by using Vibration measurement technique. In situ conditions, the junctions of a room show different behaviours when compared to those obtained in laboratory. Measurements were performed to compare the results obtained by the pressure measurement procedure according to EN 140-4 and the prediction results obtained by the methods described in the standard EN 12354-1. Also the Intensity measurement technique was used to evaluate the contribution of each wall and flanking paths, which were compared with the results obtained by the Vibration measurements procedure. The main issue is to use the prediction models previously referred for validation to the particular Spanish buildings. |
id |
RCAP_06febab2f148e5ad752c3ed27a9de3eb |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/1575 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmissionBuilding acousticsFlanking transmissionFlanking transmission in building structures can be estimated using the Intensity technique according to the method described in the standard EN 15186-2 Annex C. This can also be done by using Vibration measurement technique. In situ conditions, the junctions of a room show different behaviours when compared to those obtained in laboratory. Measurements were performed to compare the results obtained by the pressure measurement procedure according to EN 140-4 and the prediction results obtained by the methods described in the standard EN 12354-1. Also the Intensity measurement technique was used to evaluate the contribution of each wall and flanking paths, which were compared with the results obtained by the Vibration measurements procedure. The main issue is to use the prediction models previously referred for validation to the particular Spanish buildings.Biblioteca Digital do IPBAndrade, Carlos A.R.González, JulioMachimbarrena, MaríaHerráez, Marta2010-01-30T13:44:17Z20052005-01-01T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10198/1575enginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-05-21T01:17:48Zoai:bibliotecadigital.ipb.pt:10198/1575Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T11:16:07.045701Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
title |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
spellingShingle |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission Andrade, Carlos A.R. Building acoustics Flanking transmission |
title_short |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
title_full |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
title_fullStr |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
title_full_unstemmed |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
title_sort |
Validation of EN 12354-1 prediction models by means of Intensity and Vibration measurement techniques in Spanish buildings involving flanking airborne sound transmission |
author |
Andrade, Carlos A.R. |
author_facet |
Andrade, Carlos A.R. González, Julio Machimbarrena, María Herráez, Marta |
author_role |
author |
author2 |
González, Julio Machimbarrena, María Herráez, Marta |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Andrade, Carlos A.R. González, Julio Machimbarrena, María Herráez, Marta |
dc.subject.por.fl_str_mv |
Building acoustics Flanking transmission |
topic |
Building acoustics Flanking transmission |
description |
Flanking transmission in building structures can be estimated using the Intensity technique according to the method described in the standard EN 15186-2 Annex C. This can also be done by using Vibration measurement technique. In situ conditions, the junctions of a room show different behaviours when compared to those obtained in laboratory. Measurements were performed to compare the results obtained by the pressure measurement procedure according to EN 140-4 and the prediction results obtained by the methods described in the standard EN 12354-1. Also the Intensity measurement technique was used to evaluate the contribution of each wall and flanking paths, which were compared with the results obtained by the Vibration measurements procedure. The main issue is to use the prediction models previously referred for validation to the particular Spanish buildings. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005 2005-01-01T00:00:00Z 2010-01-30T13:44:17Z |
dc.type.driver.fl_str_mv |
conference object |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/1575 |
url |
http://hdl.handle.net/10198/1575 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833591749322211328 |