Export Ready — 

Removal torque of zirconia abutment screws under dry and wet conditions

Bibliographic Details
Main Author: Nigro,Frederico
Publication Date: 2010
Other Authors: Sendyk,Claudio L., Francischone Jr.,Carlos Eduardo, Francischone,Carlos Eduardo
Format: Article
Language: eng
Source: Brazilian Dental Journal
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000300009
Summary: The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
id FUNORP-1_ccb11a8fbd62f14da9f619e1fe5b4857
oai_identifier_str oai:scielo:S0103-64402010000300009
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Removal torque of zirconia abutment screws under dry and wet conditionsDental implantsabutment screwzirconium oxidetorque tighteningpreloadThe aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.Fundação Odontológica de Ribeirão Preto2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000300009Brazilian Dental Journal v.21 n.3 2010reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402010000300009info:eu-repo/semantics/openAccessNigro,FredericoSendyk,Claudio L.Francischone Jr.,Carlos EduardoFrancischone,Carlos Eduardoeng2010-09-08T00:00:00Zoai:scielo:S0103-64402010000300009Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2010-09-08T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Removal torque of zirconia abutment screws under dry and wet conditions
title Removal torque of zirconia abutment screws under dry and wet conditions
spellingShingle Removal torque of zirconia abutment screws under dry and wet conditions
Nigro,Frederico
Dental implants
abutment screw
zirconium oxide
torque tightening
preload
title_short Removal torque of zirconia abutment screws under dry and wet conditions
title_full Removal torque of zirconia abutment screws under dry and wet conditions
title_fullStr Removal torque of zirconia abutment screws under dry and wet conditions
title_full_unstemmed Removal torque of zirconia abutment screws under dry and wet conditions
title_sort Removal torque of zirconia abutment screws under dry and wet conditions
author Nigro,Frederico
author_facet Nigro,Frederico
Sendyk,Claudio L.
Francischone Jr.,Carlos Eduardo
Francischone,Carlos Eduardo
author_role author
author2 Sendyk,Claudio L.
Francischone Jr.,Carlos Eduardo
Francischone,Carlos Eduardo
author2_role author
author
author
dc.contributor.author.fl_str_mv Nigro,Frederico
Sendyk,Claudio L.
Francischone Jr.,Carlos Eduardo
Francischone,Carlos Eduardo
dc.subject.por.fl_str_mv Dental implants
abutment screw
zirconium oxide
torque tightening
preload
topic Dental implants
abutment screw
zirconium oxide
torque tightening
preload
description The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000300009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402010000300009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402010000300009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.21 n.3 2010
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091354972160